Tinaquant IgM Gen2 5220726190Recalls & reported problems
Roche Diagnostics GmbH · Class 2
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 04015630925742), received between Sep 27, 2023 and Feb 23, 2026 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Non Reproducible Results” (2 reports).
1 other recall cover devices cleared under the same FDA submission (K040431); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Non Reproducible Results2
- High Test Results1
- Incorrect Measurement1
Patient problems
- No Clinical Signs, Symptoms or Conditions3
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 23, 2026High Test Results
WE RECEIVED AN ALLEGATION ABOUT DISCREPANT RESULTS FOR 1 PATIENT SAMPLE TESTED WITH TINA-QUANT IGM GEN.2 ASSAY ON A COBAS 8000 C702 MODULE. ON (B)(6) 2026: INITIAL RESULT: 2894.9 MG/DL (ACCOMPANIED BY AN INVALIDATING DATA FLAG). 1ST REPEAT RESULT: 2816.1 MG/DL (TESTED WITH DILUTION). ON (B)(6) 2026: THE PHYSICIAN REQUESTED THAT A PROTEIN ELECTROPHORESIS BE PERFORMED, AND THE ELECTROPHORESIS IMAGE DID NOT CORRESPOND TO THE IGM VALUE, WHICH IS AROUND 2000 MG/DL. THE ORIGINAL SAMPLE WAS THEN REPEATED, AND THE 2ND REPEAT RESULT WAS APPROXIMATELY 300 MG/DL. NO EXACT RESULT WAS PROVIDED. ON (B)(6) 2026: 3RD REPEAT RESULT: 278 MG/DL. THE 2ND REPEAT RESULT OF APPROXIMATELY 300 MG/DL WAS DEEMED TO BE CORRECT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24420356 ↗MalfunctionJul 22, 2024Incorrect Measurement; Non Reproducible Results; Incorrect Measurement; Non Reproducible Results
THE INITIAL REPORTER STATED THEY RECEIVED QUESTIONABLE RESULTS FOR ONE PATIENT SAMPLE TESTED WITH TINA-QUANT IGM GEN.2 ON A COBAS 8000 C702 MODULE. THE PATIENT SAMPLE WAS ANALYZED VIA ELECTROPHORESIS, RESULTING IN AN IGM VALUE OF 50 G/L ON (B)(6) 2024. WHEN THE PATIENT SAMPLE WAS TESTED ON THE C 702 ANALYZER, IT RESULTED IN VALUES OF 4.249 G/L ON (B)(6) 2024, 4.787 G/L ON (B)(6) 2024, AND 5.152 G/L ON (B)(6) 2024. THE PATIENT SAMPLE RESULTED IN AN ADDITIONAL VALUE OF 4.23 G/L WHEN TESTED ON THE C702 ANALYZER. THE SAMPLE WAS AUTOMATICALLY DILUTED ON THE ANALYZER 1:10 AND REPEATED, RESULTING IN A RAW VALUE OF 0.529 G/L ON (B)(6) 2024. THIS CALCULATES TO A FINAL VALUE OF 5.29 G/L.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19795236 ↗MalfunctionSep 27, 2023Non Reproducible Results; Non Reproducible Results
THE INITIAL REPORTER STATED THEY RECEIVED DISCREPANT RESULTS FOR ONE PATIENT SAMPLE TESTED WITH IGM-2 ON A COBAS 8000 C702 MODULE. THE SAMPLE INITIALLY RESULTED IN AN IGM VALUE OF 39.66 G/L WITH A DATA FLAG. THE SAMPLE WAS REPEATED THREE ADDITIONAL TIMES USING A DECREASED SAMPLE VOLUME, RESULTING IN IGM VALUES OF 70.63 G/L WITH A DATA FLAG, 69.39 G/L, AND 69.93 G/L. THE SAMPLE WAS DILUTED 1:20 AND REPEATED, RESULTING IN AN IGM VALUE OF 36.93 G/L WITH A DATA FLAG. THE SAMPLE WAS REPEATED USING AN INCREASED SAMPLE VOLUME, RESULTING IN AN IGM VALUE OF 0.14 G/L.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17828838 ↗
FDA clearance and classification
Cleared through Special 510(k) K040431 on Mar 10, 2004 (decision: Substantially Equivalent). Submitted by Roche Diagnostics Corp. as “Roche Diagnostics Tina-Quant Igm Gen.2”. The FDA review took 20 days. FDA record ↗
The FDA regulates product code DAO (igm (mu chain specific), antigen, antiserum, control) under 21 CFR 866.5550 as a Class II device. 21 CFR 866.5550 ↗
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Recalls under the same FDA submission
These recalls involve devices cleared under K040431. One submission often covers many models, so check the product and lot details in each record.
- Z-1147-2019 · Dec 17, 2018 · TerminatedTina-quant IgM Gen.2, Catalog Nos. 03507190190, 05220726190, 03507041190, 03507149190 Product Usage: Immunoturbidimetric assay for the quantitative in vitro determination of IgM i
Common questions about the Tinaquant IgM Gen2 5220726190
Has the Tinaquant IgM Gen2 5220726190 been recalled?
No FDA recall record in our data names this exact device identifier (DI 04015630925742), based on the FDA recall file dated Nov 27, 2026. However, 1 recall involves devices cleared under the same FDA submission. It may or may not include this model, so check the product, model and lot details in that record.
What problems have been reported with the Tinaquant IgM Gen2 5220726190?
The FDA's MAUDE database lists 3 adverse event reports for this device, received between Sep 27, 2023 and Feb 23, 2026. In those reports, the most common specific device problems are “Non Reproducible Results” (2), “High Test Results” (1) and “Incorrect Measurement” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Tinaquant IgM Gen2 5220726190?
None of the reports are classified as deaths, 0 as injuries and 3 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the Tinaquant IgM Gen2 5220726190 FDA approved?
It was cleared through Special 510(k) K040431 on Mar 10, 2004. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Who makes the Tinaquant IgM Gen2 5220726190, and is it still sold?
The FDA's device database lists Roche Diagnostics GmbH as the company responsible for it (brand Tinaquant IgM Gen2, model 5220726190). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other IGM (MU CHAIN SPECIFIC), ANTIGEN, ANTISERUM, CONTROL devices
- Tina-quant IgM Gen.2 08057923190Roche Diagnostics GmbH · IGM (MU CHAIN SPECIFIC), ANTIGEN, ANTISERUM, CONTROL3 reports
- Tinaquant IgM Gen2 3507190190Roche Diagnostics GmbH · IGM (MU CHAIN SPECIFIC), ANTIGEN, ANTISERUM, CONTROL1 report
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page