cobas u 601 urine analyzer 06390498001Recalls & reported problems
Roche Diagnostics GmbH · Class 1
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 8
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 04015630932443), received between Jan 25, 2019 and Jul 28, 2026 — classified as 8 malfunctions.
The most frequently reported specific device problem is “Incorrect, Inadequate or Imprecise Result or Readings” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Incorrect, Inadequate or Imprecise Result or Readings2
- Optical Problem2
- False Negative Result1
- Intermittent Program or Algorithm Execution1
- Low Test Results1
- Missing Test Results1
- Non Reproducible Results1
- Patient Data Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions6
- No Known Impact Or Consequence To Patient2
- Insufficient Information1
Recent adverse event reports
The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 28, 2026Non Reproducible Results
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50052861 ↗MalfunctionFeb 9, 2026Incorrect, Inadequate or Imprecise Result or Readings; Intermittent Program or Algorithm Execution
WE RECEIVED AN ALLEGATION OF A SAMPLE MISMATCH FOR EIGHTY (80) URINE PATIENT SAMPLES TESTED ON THE COBAS U 601 URINE ANALYZER. THE REPORTER STATED THAT SOME PATIENT SAMPLES HAD AN ERYTHROCYTE RESULT OF "+3" OR "+4", BUT NO ERYTHROCYTES WERE DETECTED IN THE MICROSCOPIC READING. THEY SUSPECT A SAMPLE MISMATCH, AS THE SAMPLE IN ONE RACK POSITION WAS WAITING FOR THE SAMPLE RACK IN ANOTHER POSITION OF THE FOLLOWING RACK TO BE COMPLETED BEFORE THE RESULT WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24295655 ↗MalfunctionJan 30, 2026False Negative Result
WE RECEIVED AN ALLEGATION ABOUT A QUESTIONABLE NEGATIVE RESULT NOT CORRESPONDING TO THE CLINICAL PICTURE FOR 1 PATIENT TESTED WITH COBAS U PACK URINE TEST STRIP ON A COBAS U 601 URINE ANALYZER. THE SAMPLE WAS TESTED ON THE COBAS U 601 URINE ANALYZER AND OBTAINED A NEGATIVE LEU (LEUCOCYTES) RESULT. THE RESULT DID NOT MATCH THE PATIENT'S CLINICAL DIAGNOSIS, PROMPTING THE CUSTOMER TO EXAMINE THE SAMPLE MICROSCOPICALLY AND OBSERVE NEUTROPHILS, SUGGESTING A POSITIVE RESULT. NO QUESTIONABLE RESULT WAS RELEASED OUTSIDE THE LABORATORY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24221540 ↗MalfunctionMar 30, 2023Optical Problem; Missing Test Results; Optical Problem; Missing Test Results
THE CUSTOMER ALLEGED SAMPLE MISMATCH WHILE WORKING IN A SEQUENCE MODE WITHOUT BARCODES ON THE COBAS 6500 U601 URINE ANALYZER USING SOFTWARE VERSION V2.3.7. THE CUSTOMER STARTED ROUTINE TESTING WITH A SAMPLE IDENTIFIED AS N1 AND RACK NUMBER: 0001 SO THAT TUBES IDENTIFIED AS N6-N10 WENT TO RACK NUMBER: 0002, TUBES IDENTIFIED AS N11-N15 TO RACK NUMBER: 0003, TUBES IDENTIFIED AS N16-N20 TO RACK NUMBER: 0004, AND TUBES IDENTIFIED AS N21-N25 WERE EXPECTED TO GO TO RACK NUMBER: 0005, BUT A MISMATCH OCCURRED. THE SAMPLE IDENTIFIED AS N25 WAS IN POSITION 3 OF THE RACK AND A SAMPLE IDENTIFIED AS N27 WAS IN POSITION 4. AS A RESULT, ALL OTHER NUMBERS WERE SHIFTED.
Patient problems: Insufficient Information; No Clinical Signs, Symptoms or Conditions
MAUDE report 16648489 ↗MalfunctionJun 7, 2022Patient Data Problem; Patient Data Problem
THERE WAS AN ALLEGATION OF A SOFTWARE ISSUE FOR THE COBAS U 601 URINE ANALYZER. THE ALLEGED ISSUE WAS THAT A SAMPLE BARCODE ID WAS INCORRECTLY READ. SAMPLE B DISPLAYED SAMPLE A'S BARCODE AND ANOTHER SET OF RESULTS. SAMPLE A HAD THE CORRECT BARCODE ID AND RESULTS. THE BARCODE ID WAS NOT READ CORRECTLY FOR SAMPLE B. THE RESULTS WERE MANUALLY CHECKED AND WERE NOT REPORTED OUTSIDE OF THE LABORATORY. THE SOFTWARE VERSION IS 2.2.10.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14621705 ↗MalfunctionSep 10, 2021Optical Problem; Optical Problem
THE INITIAL REPORTER ALLEGED A POSSIBLE SAMPLE MISMATCH ISSUE WITH A COBAS U601 URINE ANALYZER. THE SAMPLE IDS AFFECTED WERE (B)(6) WHEN THE ANALYZER WAS IN "SERIAL NUMBER" MODE. THE SAMPLE TUBE WAS NOT DETECTED BY THE U601 ANALYZER BUT WAS DETECTED BY THE U701 ANALYZER. THE RESULTS FROM SAMPLE TUBE ID (B)(6) APPEARED TO BE FROM A SAMPLE TUBE WITH ID (B)(6). THE PATIENT RESULTS DO NOT CORRESPOND TO THE SAMPLE IDS ON THE SAMPLE TUBES. THE OPERATOR WAS MONITORING THE ANALYZER AND NOTICED THAT SOME SAMPLE TUBES WERE NOT DETECTED BY THE U601 ANALYZER AND DELETED THE SAMPLE NUMBERS. NO INCORRECT RESULTS WERE REPORTED OUTSIDE OF THE LABORATORY.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12453674 ↗MalfunctionApr 25, 2019Low Test Results; Low Test Results
THIS REPORT SUMMARIZES <NOE>1</NOE> MALFUNCTION EVENT. AN ERRONEOUS LOW RESULT WAS GENERATED BY THE COBAS U 601 URINE ANALYZER THE EVENTS INVOLVED A TOTAL OF 1 PATIENT WITH THE FOLLOWING: A FALSE NEGATIVE BACTERIA RESULT.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8549744 ↗MalfunctionJan 25, 2019Incorrect, Inadequate or Imprecise Result or Readings; Incorrect, Inadequate or Imprecise Result or Readings
THIS REPORT SUMMARIZES <NOE>1</NOE> MALFUNCTION EVENT. TWO RESULTS WERE MISMATCHED BY THE COBAS U 601 URINE ANALYZER. THE EVENTS INVOLVED A TOTAL OF ONE PATIENT WITH THE FOLLOWING: TWO ERRONEOUS RESULT FOR AN UNKNOWN TEST. THE PATIENT'S AGE WAS REQUESTED, BUT NOT PROVIDED. THE PATIENT'S WEIGHT WAS REQUESTED, BUT NOT PROVIDED. THE PATIENT'S GENDER WAS REQUESTED, BUT NOT PROVIDED. THE PATIENT'S RACE WAS REQUESTED, BUT NOT PROVIDED. THE PATIENT'S ETHNICITY WAS REQUESTED, BUT NOT PROVIDED.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8278152 ↗
Other AUTOMATED URINALYSIS SYSTEM devices
- iQ200 Elite Plus (US) (2008 Version) (NA)Beckman Coulter Ireland Inc. · Automated Urinalysis System3 recalls2 reports
- iQ200 Sprint Pro (NA)/SPRINT w load/unload (NA)/SPRINT Pro w load/unload (NA)/Sprint PBeckman Coulter Ireland Inc. · Automated Urinalysis System3 recalls1 report
- iQ200 Select/Elite Pro (NA)Beckman Coulter Ireland Inc. · Automated Urinalysis System3 recalls0 reports
- iQ200 Select Plus Kit 2008 Analyzer (NA)/ Select Pro (NA)Beckman Coulter Ireland Inc. · Automated Urinalysis System2 recalls4 reports
- iChem Velocity Back-Integrated Velocity (NA)Beckman Coulter Ireland Inc. · Automated Urinalysis System1 recall15 reports
- Aution™ Hybrid AU-4050 Chemical Analyzer 14603Arkray USA, Inc. · Automated Urinalysis System1 recall4 reports
- iChem Velocity Elite/Stand-Alone Velocity (NA)Beckman Coulter Ireland Inc. · Automated Urinalysis System1 recall0 reports
- UA Win10 Kit C52900Beckman Coulter Ireland Inc. · Automated Urinalysis System1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page