Skip to content

Endo-Model Standard Knee Prosthesis System 15-2975/12Recalls & reported problems

WALDEMAR LINK GmbH & Co. KG · Centralizer · Class 2 · Implant

All models of Endo-Model Standard Knee Prosthesis System (15)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 04026575205943), received between Sep 23, 2026 and Sep 24, 2026 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Nonstandard Device” (2 reports).

16 other recalls cover devices cleared under the same FDA submission (K151008); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 2 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Nonstandard Device2

Patient problems

  • No Clinical Signs, Symptoms or Conditions2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 24, 2026Nonstandard Device

    Notified on 9/17/2026 in response to an email requesting to quarantine the product, that he opened 2 parts in a procedure on (b)(6)2026 and noticed that the parts were a different size other than the size called out on the label. There wasn't much delay in the procedure and no patient harm. The decision was made at the time to use a size 14 instead and that product was available to use and was the correct size. "[Customer]".

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50877889 ↗
  • MalfunctionSep 23, 2026Nonstandard Device

    The product inside the box was the incorrect size. "[Customer]".

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50865251 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K151008. One submission often covers many models, so check the product and lot details in each record.

  • Z-1515-2026 · Jan 12, 2026 · Open, Classified
    Endo-Model Replacement Plateau; Item Number: 15-2835/12;
  • Z-1513-2026 · Jan 12, 2026 · Open, Classified
    Endo-Model SL Connection Component incl. PE-Plateau; Item Number: 16-2840/02;
  • Z-1519-2026 · Jan 12, 2026 · Open, Classified
    Endo-Model Replacement Plateau; Item Number: 15-8521/11;
  • Z-1521-2026 · Jan 12, 2026 · Open, Classified
    Endo-Model Replacement Plateau; Item Number: 15-0027/11;
  • Z-1523-2026 · Jan 12, 2026 · Open, Classified
    Endo-Model Replacement Plateau; Item Number: 15-0027/16;
  • Z-1517-2026 · Jan 12, 2026 · Open, Classified
    Endo-Model Replacement Plateau; Item Number: 15-8030/12;
  • Z-1516-2026 · Jan 12, 2026 · Open, Classified
    Endo-Model Replacement Plateau; Item Number: 15-2836/11;
  • Z-1511-2026 · Jan 12, 2026 · Open, Classified
    Endo-Model SL Connection Component incl. PE-Plateau; Item Number: 16-2840/05;
  • Z-1520-2026 · Jan 12, 2026 · Open, Classified
    Endo-Model Replacement Plateau; Item Number: 15-8521/15;
  • Z-1512-2026 · Jan 12, 2026 · Open, Classified
    Endo-Model Replacement Plateau; Item Number: 15-0027/15;
  • Z-1522-2026 · Jan 12, 2026 · Open, Classified
    Endo-Model Replacement Plateau; Item Number: 15-0027/12;
  • Z-1514-2026 · Jan 12, 2026 · Open, Classified
    Endo-Model SL Connection Component incl. PE-Plateau; Item Number: 16-2840/07;
  • Z-1518-2026 · Jan 12, 2026 · Open, Classified
    Endo-Model Replacement Plateau; Item Number: 15-8521/09;
  • Z-0890-2026 · Nov 10, 2025 · Open, Classified
    Endo Model Knee Fusion Nail SK, Knee Fusion Nail, Coupling Component, right, modular, L= 68 mm, Taper 10/12. Knee component of limb salvage replacement devices.
  • Z-2410-2024 · May 22, 2024 · Open, Classified
    Endo Model M Tibial Components Modular Knee Prosthesis System. Product codes 15-2814/01, 15-2814/02, 15-2814/03, 15-2814/04, 15-2815/11, 15-2815/12, 15-2816/11, 15-2816/12, 15-281

…and 1 more.

Other Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Uncemented devices

All Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Uncemented devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page