TRACOE® twist REF 301-08-PRecalls & reported problems

Tracoe medical GmbH · Tracheostomy Tube with Low Pressure Cuff, with atraumatic insertion system · Class 2

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04035324015160), received between Sep 4, 2025 and Sep 4, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “Detachment of Device or Device Component” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 1 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Detachment of Device or Device Component1

Patient problems

  • Respiratory Insufficiency1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 4, 2025Detachment of Device or Device Component; Detachment of Device or Device Component

    1) THE INCIDENT OCCURRED ON (B)(6) 2025 AT APP. 06:30, THE PATIENT DEVELOPED SIGNS OF RESPIRATORY DISTRESS. MULTIPLE SUCTION ATTEMPTS WERE PERFORMED USING BOTH ORAL AND CLOSED SUCTION VIA THE TRACHEOSTOMY TUBE, BUT THESE DID NOT RELIEVE THE OBSTRUCTION. THE INNER CANNULA WAS CHECKED AND APPEARED CLEAR. WHEN ANOTHER DEEP CLOSED SUCTION ATTEMPT WAS MADE, IT BECAME APPARENT THAT THERE WAS A POSSIBLE BLOCKAGE LOCATED DEEPER THAN THE INNER CANNULA. FIO2 WAS INCREASED TO 100% AND THE VENTILATOR WAS DISCONNECTED TO ALLOW THE USE OF A TENDERTIP OPEN SUCTION CATHETER. THIS INTERVENTION PROVIDED PARTIAL RELIEF AFTER SEVERAL PASSES (APPROXIMATELY FIVE ATTEMPTS). DUE TO THE ONGOING DIFFICULTY AND SUSPICION OF A DEEPER BLOCKAGE, THE CLINICAL TEAM PERFORMED A BRONCHOSCOPY. THIS REVEALED WHAT APPEARED TO BE PLASTIC MATERIAL. OBSTRUCTING THE AIRWAY, LEAVING ONLY A SMALL RESIDUAL LUMEN. THE DEVICE'S CUFF HAD SLIPPED DOWN THE SHAFT. OF THE TUBE, PARTIALLY BLOCKING THE PATIENT'S AIRWAY. ALTHOUGH THE CUFF REMAINED ATTACHED, ITS DISPLACEMENT BEYOND THE DISTAL END OF THE TUBE CAUSED THE OBSTRUCTION. THE DECISION WAS MADE TO IMMEDIATELY REPLACE THE TRACHEOSTOMY TUBE. 2)FOLLOWING TUBE EXCHANGE, SUCTIONING

    Patient problems: Respiratory Insufficiency

    MAUDE report 22960636 ↗

Other Tube tracheostomy and tube cuff devices

All Tube tracheostomy and tube cuff devices →