Skip to content

TRACOE® twist REF 306-08-PRecalls & reported problems

Tracoe medical GmbH · Tracheostomy Tube, with Low Pressure Cuff and Subglottic Suction Line, with atraumatic insertion system · Class 2

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04035324016884), received between Aug 18, 2025 and Aug 18, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “Complete Blockage” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 1 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Complete Blockage1
  • Inflation Problem1

Patient problems

  • Respiratory Insufficiency1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionAug 18, 2025Complete Blockage; Inflation Problem; Complete Blockage; Inflation Problem

    1) WHAT WENT WRONG: DURING A TRACHEOSTOMY PROCEDURE USING THE TRACOE EXPERC SET (REF (B)(4) WITH CANNULA MODEL 306-08-P, A MALFUNCTION OCCURRED AT THE STAGE OF INSERTING AND LOCKING THE INNER CANNULA. THE CONNECTION TUBE (FILLING LINE) BETWEEN THE CUFF AND THE PILOT BALLOON BECAME INADVERTENTLY TRAPPED BETWEEN THE OUTER AND INNER CANNULAE WITHIN THE LOCKING MECHANISM. AS A RESULT, THE CUFF COULD NOT BE INFLATED PROPERLY DUE TO COMPRESSION OF THE CUFF TUBING. EVEN AFTER THE CONNECTION TUBE WAS RELEASED, THE INFLATION SYSTEM DID NOT FUNCTION AS EXPECTED. HIGHER-THAN-NORMAL INFLATION PRESSURES WERE REQUIRED, AND DEFLATION/ASPIRATION FROM THE CUFF REMAINED INCOMPLETE. CONSEQUENTLY, EFFECTIVE PATIENT VENTILATION COULD NOT BE ENSURED - BECAUSE OF THE REDUCED BLOCKING OF THE CUFF. 2) HEALTH EFFECT: THE PATIENT HAD TO UNDERGO EMERGENCY OROTRACHEAL INTUBATION FOLLOWED BY A REPEAT TRACHEOTOMY, WHICH WAS SUCCESSFULLY COMPLETED WITHOUT FURTHER COMPLICATION NO FURTHER HEALTH EFFECT TO THE PATIENT REPORTED.

    Patient problems: Respiratory Insufficiency

    MAUDE report 22827484 ↗

Other Tube tracheostomy and tube cuff devices

All Tube tracheostomy and tube cuff devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page