TRACOE vario REF 450-07-PRecalls & reported problems
Tracoe medical GmbH · TRACOE vario Tracheostomy Tube Spiral-Reinforced, with Adjustable Neck Flange and Low Pressure Cuff, with minimally traumatic insertion system · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04035324017003), received between Dec 18, 2025 and Dec 18, 2025 — classified as 1 malfunction.
The most frequently reported specific device problem is “Loss of or Failure to Bond” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Loss of or Failure to Bond1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionDec 18, 2025Loss of or Failure to Bond; Loss of or Failure to Bond
1) WHAT WENT WRONG WITH THE DEVICE: DURING THE INSERTION OF THE CANNULA (VARIO -P TUBE), THE SILICONE SLEEVE, WHICH WAS SUPPOSED TO BE REMOVED AFTER THE CANNULA WAS INSERTED, WAS NOT REMOVED. WHEN THE DOCTOR NOTICED THIS, HE REMOVED THE CANNULA ALONG WITH THE SILICONE PART, AND INSERTED A NEW CANNULA OF THE SAME TYPE INTO THE PATIENT. IN PARALLEL WITH THIS OPERATION, MANUAL VENTILATION WAS PERFORMED SINCE AN ALERT WAS RECEIVED THAT THE PATIENT WAS NOT CONNECTED TO THE MECHANICAL VENTILATOR, BUT AFTER REPLACING THE CANNULA, AS DESCRIBED ABOVE, THE VENTILATOR WORKED PROPERLY, AND THE PATIENT WAS VENTILATED. 2) DESCRIPTION OF HEALTH EFFECTS: NO HARM WAS CAUSED TO THE PATIENT. IT SHOULD BE NOTED THAT THIS IS THE SECOND SIMILAR EVENT WHICH OCCURED IN THE HOSPITAL.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23836610 ↗
Other Tube Tracheostomy And Tube Cuff devices
- Shiley 8CN85HCovidien LP · Tube tracheostomy and tube cuff1 recall2 deaths354 reports
- Shiley 6CN75HCovidien LP · Tube tracheostomy and tube cuff1 recall3 deaths240 reports
- Shiley 7CN80RCovidien LP · Tube tracheostomy and tube cuff2 recalls148 reports
- Bivona 67PFSS35Icu Medical, Inc. · Tube tracheostomy and tube cuff1 recall166 reports
- Bivona 670180Icu Medical, Inc. · Tube tracheostomy and tube cuff1 recall140 reports
- Bivona 670170Icu Medical, Inc. · Tube tracheostomy and tube cuff1 recall10 deaths132 reports
- Shiley 6CN75RCovidien LP · Tube tracheostomy and tube cuff1 recall1 death121 reports
- Bivona 67PFSS40Icu Medical, Inc. · Tube tracheostomy and tube cuff1 recall115 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page