Olympus A22001ARecalls & reported problems

OLYMPUS Winter & Ibe GmbH · Telescope, 12°, 4 mm · Class 2

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Quick summary

This Olympus hysteroscope telescope is a rigid scope used with hysteroscopes. Of its 366 reports, 364 are malfunctions and 2 are injuries, with no deaths. Many reports describe parts that break or shatter, lenses that come off, and sharp edges at the tip, and many were found during inspection with no patient involvement. No recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
366
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 366 adverse event reports that list this exact device (DI 04042761020848), received between Oct 12, 2022 and Jul 21, 2026 — classified as 2 injuries, 364 malfunctions.

The most frequently reported specific device problem is “Break” (191 reports).

1 other recall cover devices cleared under the same FDA submission (K897003); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 11 reportsJan 2024: 7 reportsFeb 2024: 3 reportsMar 2024: 11 reportsApr 2024: 8 reportsMay 2024: 5 reportsJun 2024: 8 reportsJul 2024: 11 reportsAug 2024: 11 reportsSep 2024: 7 reportsOct 2024: 12 reportsNov 2024: 8 reportsDec 2024: 2 reportsJan 2025: 8 reportsFeb 2025: 17 reportsMar 2025: 13 reportsApr 2025: 8 reportsMay 2025: 10 reportsJun 2025: 8 reportsJul 2025: 13 reportsAug 2025: 7 reportsSep 2025: 4 reportsOct 2025: 6 reportsNov 2025: 6 reportsDec 2025: 17 reportsJan 2026: 20 reportsFeb 2026: 15 reportsMar 2026: 10 reportsApr 2026: 3 reportsMay 2026: 5 reportsJun 2026: 0 reportsJul 2026: 1 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reportsNov 2026: 0 reports20242025202620
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break191
  • Detachment of Device or Device Component86
  • Component Missing16
  • Loose or Intermittent Connection16
  • Poor Quality Image13
  • Crack12
  • Mechanical Problem8
  • Material Integrity Problem5

Patient problems

  • No Clinical Signs, Symptoms or Conditions365
  • Hemorrhage/Blood Loss/Bleeding1
  • Hyponatremia1
  • Uterine Perforation1

Recent adverse event reports

The 25 most recent of 366 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJul 21, 2026Break

    THE CUSTOMER RETURNED THE HYSTEROSCOPE TO THE SERVICE CENTER FOR A SEPARATE ISSUE. DURING THE DEVICE ANALYSIS, THE SERVICE TEAM INDICATES INTERNAL LENS WAS SHATTERED. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25889522 ↗
  • MalfunctionMay 28, 2026Break

    THE CUSTOMER RETURNED THE GYNECOLOGY HYSTEROSCOPE TO THE SERVICE CENTER FOR A SEPARATE ISSUE. DURING THE DEVICE ANALYSIS, THE SERVICE REPAIR TECHNICIAN IDENTIFIED THAT THE INTERNAL LENS WAS SHATTERED, AND IT WAS DETERMINED THAT THE DAMAGE WAS CAUSED BY A FAILURE OF THE INTERNAL LENS COMPONENT. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25323161 ↗
  • MalfunctionMay 23, 2026Sharp Edges

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE HYSTEROSCOPE, GYNECOLOGY HAD SHARP EDGES AT THE DISTAL END. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25264252 ↗
  • MalfunctionMay 23, 2026Break

    THE HYSTEROSCOPE, GYNECOLOGY WAS RETURNED TO THE SERVICE CENTER WITH A REPORT OF NO CUSTOMER ALLEGATION. THIS DOES NOT INDICATE AN MDR REPORTABLE EVENT. HOWEVER, MDR REPORTABLE FAILURE WAS FOUND DURING TESTING AT THE SERVICE CENTER. DURING INSPECTION OF THE DEVICE, SHARP EDGES ON THE DISTAL END WAS FOUND. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25264171 ↗
  • MalfunctionMay 21, 2026Break

    IT WAS REPORTED THAT THE GYNECOLOGY HYSTEROSCOPE HAD A SHATTERED INTERNAL LENS. THE ISSUE WAS IDENTIFIED DURING INSPECTION PRIOR TO USE. THERE WERE NO REPORTS OF PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25243714 ↗
  • MalfunctionMay 4, 2026Detachment of Device or Device Component

    IT WAS REPORTED THE RIGID SCOPE HAD LENS CAME OFF DURING INSPECTION FOR USE. THERE WERE NO REPORTS OF PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25075570 ↗
  • MalfunctionApr 27, 2026Detachment of Device or Device Component

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE HYSTEROSCOPE, GYNECOLOGY EXHIBITED DETACHMENT OF THE OBJECTIVE LENS. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25010534 ↗
  • MalfunctionApr 25, 2026Break

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE OLYMPUS HYSTERORESECTOSCOPE HAD SHATTERED INTERNAL LENS. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24991791 ↗
  • MalfunctionApr 1, 2026Material Split, Cut or Torn

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE GYNECOLOGY HYSTEROSCOPE HAD MENISCUS CHIPPED AND TOUCHING COVER GLASS. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24754899 ↗
  • MalfunctionMar 30, 2026Loose or Intermittent Connection

    IT WAS REPORTED THE HYSTERORESECTOSCOPE EXHIBITED MISALIGNED LENS. THE ISSUE OCCURRED DURING THE MAINTENANCE. THERE WERE NO REPORTS OF PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24733729 ↗
  • MalfunctionMar 25, 2026Break

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE HYSTEROSCOPE, GYNECOLOGY EXHIBITED CHIPPED LENSES. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24691230 ↗
  • MalfunctionMar 25, 2026Sharp Edges

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE GYNECOLOGY HYSTEROSCOPE HAD A SHARP EDGES AND DAMAGED GLASS DISTAL END. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24689333 ↗
  • MalfunctionMar 24, 2026Detachment of Device or Device Component

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE HYSTEROSCOPE, GYNECOLOGY EXHIBITED CHIPPED LENSES. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24672499 ↗
  • MalfunctionMar 23, 2026Break; Detachment of Device or Device Component

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE HYSTEROSCOPE, GYNECOLOGY HAD EXTREMELY WORN DISTAL TERMINAL AND BROKEN DISTAL LENS. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24661243 ↗
  • MalfunctionMar 19, 2026Break

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE RIGID SCOPE EXHIBITED DAMAGED DISTAL END. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24643469 ↗
  • MalfunctionMar 17, 2026Detachment of Device or Device Component

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE GYNECOLOGY HYSTEROSCOPE EXHIBITED THAT THE DISTAL END LENS WAS SHIFTED. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24617220 ↗
  • MalfunctionMar 9, 2026Break

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE GYNECOLOGY HYSTEROSCOPE HAD EXHIBITED A BROKEN AND CHIPPED INNER BARREL ASSEMBLY. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24550782 ↗
  • MalfunctionMar 3, 2026Detachment of Device or Device Component

    NO ADDITIONAL INFORMATION RECEIVED FROM THE CUSTOMER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24503149 ↗
  • MalfunctionMar 2, 2026Detachment of Device or Device Component

    IT WAS REPORTED THE HYSTEROSCOPE, GYNECOLOGY HAD THE PIN HAD COMES OFF. THE EVENT HAD OCCURRED DURING REPROCESSING. THERE WERE NO REPORTS OF PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24487997 ↗
  • MalfunctionFeb 27, 2026Detachment of Device or Device Component

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE HYSTEROSCOPE GYNECOLOGY HAD A LOOSE MENISCUS ON THE OBJECTIVE WINDOW. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24471456 ↗
  • MalfunctionFeb 27, 2026Detachment of Device or Device Component

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE HYSTEROSCOPE GYNECOLOGY HAD A DETACHED ADAPTER. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24468384 ↗
  • MalfunctionFeb 27, 2026Detachment of Device or Device Component

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE GYNECOLOGIC HYSTEROSCOPE HAD A DETACHED ADAPTER. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24468304 ↗
  • MalfunctionFeb 24, 2026Detachment of Device or Device Component

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE GYNECOLOGY HYSTEROSCOPE EXHIBITED THAT THE ADAPTER WAS DETACHED. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24431380 ↗
  • MalfunctionFeb 23, 2026Loose or Intermittent Connection

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE GYNECOLOGY HYSTEROSCOPE PRESENTED LOOSE MENISCUS. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24411796 ↗
  • MalfunctionFeb 20, 2026Loose or Intermittent Connection

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE HYSTEROSCOPE, GYNECOLOGY HAD LOOSE MODEL RING AND MENISCUS. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24399527 ↗

FDA clearance and classification

Cleared through 510(k) K897003 on Mar 16, 1990 (decision: Substantially Equivalent). Submitted by Olympus Corp. as “Olympus Hysteroresectoscope”. The FDA review took 88 days. FDA record ↗

The FDA regulates product code HIH (hysteroscope (and accessories)) under 21 CFR 884.1690 as a Class II device. 21 CFR 884.1690 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K897003. One submission often covers many models, so check the product and lot details in each record.

  • Z-2029-2024 · Apr 18, 2024 · Open, Classified
    OES 4000 Hysteroscope, Model/Catalog Number: A4674A

Common questions about the Olympus A22001A

Has the Olympus A22001A been recalled?

No FDA recall record in our data names this exact device identifier (DI 04042761020848), based on the FDA recall file dated Nov 27, 2026. However, 1 recall involves devices cleared under the same FDA submission. It may or may not include this model, so check the product, model and lot details in that record.

What problems have been reported with the Olympus A22001A?

The FDA's MAUDE database lists 366 adverse event reports for this device, received between Oct 12, 2022 and Jul 21, 2026. In those reports, the most common specific device problems are “Break” (191), “Detachment of Device or Device Component” (86) and “Component Missing” (16); the most common patient problems are “Hemorrhage/Blood Loss/Bleeding” (1), “Hyponatremia” (1) and “Uterine Perforation” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the Olympus A22001A?

None of the reports are classified as deaths, 2 as injuries and 364 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the Olympus A22001A FDA approved?

It was cleared through 510(k) K897003 on Mar 16, 1990. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.

Who makes the Olympus A22001A, and is it still sold?

The FDA's device database lists OLYMPUS Winter & Ibe GmbH as the company responsible for it (brand Olympus, model A22001A). Its record shows it as no longer in commercial distribution.