Skip to content

Olympus WA2T412ARecalls & reported problems

OLYMPUS Winter & Ibe GmbH · Telescope "OES ELITE", 4 mm, 12°, HD, autoclavable · Class 2

Quick summary

This Olympus OES Elite telescope is a rigid endoscope used to see inside the body during minimally invasive procedures. Its 456 reports mostly describe breakage, parts coming loose or detaching, cracks and loose connections. The reports include no deaths and 3 injuries. No recalls name this device.

AI-generated from the FDA records on this page and checked automatically against the numbers below. Read the details before relying on it.

Adverse event reports
453
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 453 adverse event reports that list this exact device (DI 04042761077507), received between Jul 17, 2020 and Aug 21, 2026 — classified as 3 injuries, 450 malfunctions.

The most frequently reported specific device problem is “Break” (234 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 10 reportsDec 2023: 9 reportsJan 2024: 8 reportsFeb 2024: 3 reportsMar 2024: 15 reportsApr 2024: 11 reportsMay 2024: 10 reportsJun 2024: 11 reportsJul 2024: 9 reportsAug 2024: 10 reportsSep 2024: 14 reportsOct 2024: 18 reportsNov 2024: 13 reportsDec 2024: 5 reportsJan 2025: 12 reportsFeb 2025: 22 reportsMar 2025: 18 reportsApr 2025: 7 reportsMay 2025: 14 reportsJun 2025: 20 reportsJul 2025: 15 reportsAug 2025: 11 reportsSep 2025: 8 reportsOct 2025: 6 reportsNov 2025: 8 reportsDec 2025: 18 reportsJan 2026: 18 reportsFeb 2026: 15 reportsMar 2026: 11 reportsApr 2026: 4 reportsMay 2026: 2 reportsJun 2026: 3 reportsJul 2026: 2 reportsAug 2026: 3 reportsSep 2026: 0 reportsOct 2026: 0 reports20242025202622
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break234
  • Detachment of Device or Device Component81
  • Loose or Intermittent Connection35
  • Crack29
  • Component Missing12
  • Fracture10
  • Poor Quality Image10
  • Degraded8

Patient problems

  • No Clinical Signs, Symptoms or Conditions452
  • No Code Available1

Recent adverse event reports

The 25 most recent of 453 reports, in the reporter's own words as published by the FDA.

  • MalfunctionAug 21, 2026Break

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50376508 ↗
  • MalfunctionAug 11, 2026Break

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50207893 ↗
  • MalfunctionAug 11, 2026Detachment of Device or Device Component

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50201344 ↗
  • MalfunctionJul 27, 2026Break

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50043976 ↗
  • MalfunctionJul 17, 2026Break

    THE CUSTOMER RETURNED THE RIGID ENDOSCOPE TELESCOPE TO THE SERVICE CENTER FOR A SEPARATE ISSUE. DURING THE DEVICE ANALYSIS, THE SERVICE TEAM INDICATES THAT AN INTERNAL LENS WAS SHATTERED. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25856301 ↗
  • MalfunctionJun 25, 2026Degraded

    THE CUSTOMER RETURNED THE RIGID ENDOSCOPE TELESCOPE TO THE SERVICE CENTER FOR EVALUATION RELATED TO A SEPARATE ISSUE. DURING TESTING THE REPAIR CENTER TECHNICIAN FOUND CHIPPED LENS IN THE OPTICAL SYSTEM, CAUSE TRACED TO COMPONENT FAILURE. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25620470 ↗
  • MalfunctionJun 25, 2026Detachment of Device or Device Component

    THE CUSTOMER REPORTED TELESCOPE HAS CHIP DURING INSPECTION FOR USE INVOLVING AN OLYMPUS RIGID ENDOSCOPE TELESCOPE. THERE WAS NO PATIENT INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25620371 ↗
  • MalfunctionJun 5, 2026Detachment of Device or Device Component

    THE CUSTOMER RETURNED THE RIGID ENDOSCOPE TELESCOPE TO THE SERVICE CENTER FOR A SEPARATE ISSUE. DURING THE DEVICE ANALYSIS, THE INVESTIGATION INDICATES THAT A DISTAL END LENS DISPLACEMENT OCCURRED. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25415888 ↗
  • MalfunctionMay 29, 2026Material Fragmentation

    THE CUSTOMER RETURNED THE RIGID ENDOSCOPE TELESCOPE TO THE SERVICE CENTER FOR A SEPARATE ISSUE. DURING THE DEVICE ANALYSIS, THE OLYMPUS SERVICE TEAM INDICATES THAT DEVICE HAD CHIPPED LENS IN THE OPTICAL SYSTEM. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25334018 ↗
  • MalfunctionMay 19, 2026Sharp Edges

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE RIGID ENDOSCOPE TELESCOPE HAD A SHARP EDGES ON DISTAL END. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 25222192 ↗
  • MalfunctionApr 21, 2026Material Split, Cut or Torn

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE RIGID SCOPE HAD CHIPPED LENS IN THE OPTICAL SYSTEM. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24942298 ↗
  • MalfunctionApr 15, 2026Crack

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE RIGID ENDOSCOPE TELESCOPE HAD CHIPPED OPTICAL LENS. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24887242 ↗
  • MalfunctionApr 11, 2026Break

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE RIGID ENDOSCOPE TELESCOPE EXHIBITED INTERNAL LENS WAS SHATTERED. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24848920 ↗
  • MalfunctionApr 8, 2026Material Fragmentation

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE RIGID ENDOSCOPE TELESCOPE PRESENTED CHIPPED OPTICAL LENS. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24814466 ↗
  • MalfunctionMar 31, 2026Component Missing

    IT WAS REPORTED THAT THE RIGID ENDOSCOPE TELESCOPE HAD A PIN MISSING ON THE OPTICS, FOUND DURING INSPECTION FOR USE. THERE WERE NO REPORTS OF PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24746442 ↗
  • MalfunctionMar 30, 2026Break

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE RIGID OPTICAL LAPAROSCOPE HAD CHIPPED LENS IN OPTICAL SYSTEM THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24713041 ↗
  • MalfunctionMar 30, 2026Break

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE RIGID ENDOSCOPE TELESCOPE PRESENTED CHIPPED LENS. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24711180 ↗
  • MalfunctionMar 25, 2026Break

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE RIGID ENDOSCOPE TELESCOPE EXHIBITED INTERNAL LENS WAS SHATTERED. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24686639 ↗
  • MalfunctionMar 24, 2026Material Separation

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE RIGID ENDOSCOPE TELESCOPE EXHIBITED CHIPPED LENS IN OPTICAL SYSTEM. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24683175 ↗
  • MalfunctionMar 24, 2026Detachment of Device or Device Component

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE RIGID ENDOSCOPE TELESCOPE EXHIBITED CHIPPED LENS. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24676943 ↗
  • MalfunctionMar 23, 2026Detachment of Device or Device Component

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE RIGID ENDOSCOPE TELESCOPE EXHIBITED CHIPPED OPTICAL LENS. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24663343 ↗
  • MalfunctionMar 23, 2026Material Discolored

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE RIGID ENDOSCOPE TELESCOPE HAD CHIPPED OPTICAL LENS. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24661704 ↗
  • MalfunctionMar 19, 2026Material Separation

    IT WAS OBSERVED THAT DURING THE DEVICE EVALUATION, THE RIGID ENDOSCOPE TELESCOPE EXHIBITED CHIPPED LENS IN OPTICAL SYSTEM. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24641659 ↗
  • MalfunctionMar 9, 2026Material Fragmentation

    IT WAS OBSERVED DURING DEVICE EVALUATION, THE RIGID ENDOSCOPE TELESCOPE HAD CHIPPED OPTICAL LENS. THERE WAS NO PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24545919 ↗
  • MalfunctionMar 4, 2026Detachment of Device or Device Component

    IT WAS OBSERVED DURING THE DEVICE INSPECTION, THAT THE RIGID ENDOSCOPE TELESCOPE EXHIBITED A CHIPPED LENS. THERE WERE NO REPORTS OF PATIENT INVOLVEMENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24514031 ↗

Other Hysteroscope (And Accessories) devices

All Hysteroscope (And Accessories) devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.