Corded control device 118090A0Recalls & reported problems
MAQUET GmbH · Class 1
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 04046768032217), received between Jan 5, 2024 and Apr 5, 2024 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Electrical Shorting” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Electrical Shorting1
- Positioning Failure1
- Unintended Movement1
- Use of Device Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 5, 2024Use of Device Problem; Unintended Movement; Use of Device Problem; Unintended Movement
GETINGE BECAME AWARE OF AN EVENT WITH 118090A0 - CABLE-CONNECTED HAND CONTROL USED WITH 118001A0 - MAGNUS TABLE COLUMN FOR BUILT-IN PLATE AND 118091A0 - IR HAND CONTROL MAGNUS. AS IT WAS STATED, THE EVENT OCCURRED AFTER THE MEDICAL PROCEDURE WAS FINISHED, THE PATIENT WAS EXTUBATED AND STILL ON THE TABLETOP. THE CABLE-CONNECTED HAND CONTROL WAS PLACED ON THE SIDERAIL BETWEEN TABLETOP AND ARM REST. AFTER MOVING THE ARM REST TOWARDS THE TABLETOP, SLOW UNINTENDED MOTION INTO "HEAD DOWN" POSITION OCCURRED DUE TO ACCIDENTAL PRESSING OF HAND CONTROL BUTTONS WITH THE ARM REST. THE STAFF TRIED TO STOP THE MOVEMENT WITH THE IR CONTROLLER WHICH DID NOT WORK. ACCORDING TO THE INFORMATION PROVIDED, IT TOOK SOME TIME FOR THE STAFF TO DETERMINE THAT THE ISSUE WAS CAUSED BY CABLE-CONNECTED HAND CONTROL AND TO RELEASE IT. ACCORDING TO THE CUSTOMERS ALLEGATION IF THE MOTION HAD CONTINUED, THE PATIENT COULD HAVE BEEN AT RISK OF FALLING OFF THE OPERATING TABLE. THE EVENT WAS INITIALLY ASSESSED AS REPORTABLE DUE TO THE POTENTIAL FOR SERIOUS INJURY IF THE SITUATION, NAMELY UNINTENDED MOVEMENT OF THE TABLE AND CREATING A RISK OF FALL, WAS TO REOCCUR. RECENTLY, THE CASE HAS BEEN REEVALUATED. AFTER THE CON
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19048934 ↗MalfunctionJan 5, 2024Positioning Failure; Electrical Shorting; Positioning Failure; Electrical Shorting
ON 20TH DECEMBER 2023 GETINGE BECAME AWARE OF AN ISSUE WITH ONE OF OUR COLUMNS - 118001C0 - MAGNUS TABLE COLUMN, MOBILE. AS IT WAS STATED, NO MOVEMENT OF THE TABLE WAS POSSIBLE AT THE END OF LAST INTERVENTION OF THE DAY. IT IS UNCLEAR WHETHER THE PATIENT WAS STILL ON THE OPERATING TABLE WHEN THE ISSUE OCCURRED. ADDITIONALLY, A SURGERY WAS CANCELLED ON THE FOLLOWING DAY DUE TO THE MALFUNCTION. ACCORDING TO INFORMATION PROVIDED BY THE SERVICE TECHNICIAN FOLLOWING VISIT ON SITE, THE TABLE COULD NOT BE TEMPORARILY OPERATED VIA OVERRIDE PANEL AND THE HANDCONTROL WAS SHORT-CIRCUITED AND NOT WORKING AS WELL. HOWEVER, THE TABLE COULD BE MOVED USING ANOTHER HANDCONTROL. THERE WAS NO INJURY REPORTED, HOWEVER, WE DECIDED TO REPORT THE ISSUE BASED ON THE POTENTIAL FOR SERIOUS INJURY IF THE SITUATION, NAMELY THE OPERATING TABLE NOT RESPONDING TO REMOTE CONTROL OR OVERRIDE PANEL LEADING TO INABILITY TO POSITION THE TABLE DURING PROCEDURE, WAS TO REOCCUR.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18452382 ↗
Other TABLE, SURGICAL WITH ORTHOPEDIC ACCESSORIES, AC-POWERED devices
- TS 7000 1604788Baxter Medical Systems GmbH + Co. KG · TABLE, SURGICAL WITH ORTHOPEDIC ACCESSORIES, AC-POWERED1 recall4 reports
- TS 7500 1717023Baxter Medical Systems GmbH + Co. KG · TABLE, SURGICAL WITH ORTHOPEDIC ACCESSORIES, AC-POWERED1 recall1 report
- TS 7500 1854087Baxter Medical Systems GmbH + Co. KG · TABLE, SURGICAL WITH ORTHOPEDIC ACCESSORIES, AC-POWERED1 recall0 reports
- TS 7500 1854085Baxter Medical Systems GmbH + Co. KG · TABLE, SURGICAL WITH ORTHOPEDIC ACCESSORIES, AC-POWERED1 recall0 reports
- TS 7500 1704695Baxter Medical Systems GmbH + Co. KG · TABLE, SURGICAL WITH ORTHOPEDIC ACCESSORIES, AC-POWERED1 recall0 reports
- ADVANCED CONTROL I-BASE, DC 5803Mizuho Orthopedic Systems, Inc. · Table, Surgical With Orthopedic Accessories, Ac-Powered47 reports
- TRUMPF MEDICAL 1723633Baxter Medical Systems GmbH + Co. KG · TABLE, SURGICAL WITH ORTHOPEDIC ACCESSORIES, AC-POWERED43 reports
- TABLE, HANA, 110 V 6875Mizuho Orthopedic Systems, Inc. · Table, Surgical With Orthopedic Accessories, Ac-Powered2 deaths36 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page