MAGNUS carbon fibre table top 118016A5Recalls & reported problems
MAQUET GmbH · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04046768040779), received between Aug 2, 2023 and Aug 2, 2023 — classified as 1 malfunction.
The most frequently reported specific device problem is “Communication or Transmission Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Communication or Transmission Problem1
- Device Sensing Problem1
- Positioning Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionAug 2, 2023Communication or Transmission Problem; Device Sensing Problem; Positioning Problem; Communication or Transmission Problem; Device Sensing Problem; Positioning Problem
ON (B)(6) 2023 GETINGE BECAME AWARE OF AN ISSUE WITH ONE OF OUR COLUMNS ¿ 118001B1 - HYBRID OR TABLE COLUMN, SURFACE-MOUNTED. AS IT WAS STATED, THE COMMUNICATION ISSUES OCCURRED BETWEEN THE HYBRID OR TABLE COLUMN AND PHILIPS ANGIOGRAPHY DEVICE DURING IMAGINING. THE TABLE STOPPED MOVING TOWARDS THE HEAD SIDE. ACCORDING TO THE PROVIDED INFORMATION, FOLLOWING THE EVENT, THE ANGIOGRAPHY DEVICE WAS RESTARTED AND THE PROCEDURE WAS SUCCESSFULLY PERFORMED WITHOUT INTERLOCKING WITH THE GETINGE REMOTE CONTROL. THE ISSUE LED TO A DELAY OF APPROXIMATELY 5 MINUTES. THERE WAS NO INJURY REPORTED, HOWEVER, WE DECIDED TO REPORT THE ISSUE BASED ON THE POTENTIAL FOR SERIOUS INJURY IF THE SITUATION, NAMELY A DELAY IN SURGERY RESULTING IN PROLONGED ANESTHESIA TIME, WAS TO REOCCUR.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17447237 ↗
Other Table, radiologic devices
- ORT300 TableIMRIS Imaging, Inc. · Table, Radiologic2 recalls6 reports
- NA 6265300GE Medical Systems, L.L.C. · Table, radiologic2 recalls0 reports
- PST500 4080300Baxter Medical Systems GmbH + Co. KG · Table, radiologic1 recall4 reports
- TS 7500 1730720Baxter Medical Systems GmbH + Co. KG · Table, radiologic1 recall1 report
- TS 7500 1854086Baxter Medical Systems GmbH + Co. KG · Table, radiologic1 recall0 reports
- TS 7500 1730732Baxter Medical Systems GmbH + Co. KG · Table, radiologic1 recall0 reports
- NA 6265300-20GE Medical Systems, L.L.C. · Table, radiologic1 recall0 reports
- TS 7000 1604786Baxter Medical Systems GmbH + Co. KG · Table, radiologic1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page