MAGNUS T285.7000Recalls & reported problems

MAQUET GmbH · MAGNUS Carbon-fibre table top · Class 2

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04046768067165), received between Jun 18, 2024 and Jun 18, 2024 — classified as 1 malfunction.

The most frequently reported specific device problem is “Battery Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 1 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Battery Problem1
  • Circuit Failure1
  • Failure to Sense1
  • Loose or Intermittent Connection1
  • Power Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJun 18, 2024Circuit Failure; Loose or Intermittent Connection; Failure to Sense; Battery Problem; Power Problem; Circuit Failure; Loose or Intermittent Connection; Failure to Sense; Battery Problem; Power Problem

    ON 30TH MAY 2024, GETINGE BECAME AWARE OF AN ISSUE WITH ONE OF OUR COLUMNS - 118001B1 - HYBRID OR TABLE COLUMN, SURFACE-MOUNTED. AS IT WAS STATED, ERROR 174 (POSITION ERROR) OCCURRED WHILE MOVING THE TABLE DURING TRANSCATHETER AORTIC VALVE REPAIR ON THE ANESTHETIZED PATIENT UNDER INTRAVENOUS MODERATE SEDATION. THE STAFF WAITED FOR ALMOST AN HOUR WHILE TROUBLESHOOTING WAS DONE BEFORE THE SURGEON DECIDED TO ABORT THE CASE. THE PATIENT WAS TAKEN TO THE RECOVERY ROOM. BASED ON INFORMATION PROVIDED BY THE TECHNICIAN FOLLOWING SERVICE VISIT ON SITE, THE TABLE WAS MOVING CORRECTLY AND COMMUNICATING WITH PHILIPS SYSTEM AFTER RECALIBRATION AND RESET OF THE TABLE AND IMAGINING DEVICE. ACCORDING TO THE CUSTOMER, THE BATTERIES IN THE SYSTEM UPS HAD JUST BEEN CHANGED WHICH COULD HAVE CAUSED A POWER GLITCH THAT INTERRUPTED COMMUNICATION AND CAUSED A LOSS OF CALIBRATION DATA. THERE WAS NO INJURY REPORTED, HOWEVER, WE DECIDED TO REPORT THE ISSUE BASED ON THE POTENTIAL FOR SERIOUS INJURY IF THE SITUATION, NAMELY THE DELAY IN SURGERY RESULTING IN PROLONGED ANESTHESIA TIME LEADING TO RESCHEDULING OF THE PROCEDURE, WAS TO REOCCUR.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19555986 ↗

Other Table, Radiologic devices

All Table, Radiologic devices →