Medicon 57.28.33Recalls & reported problems
Medicon eG. Chirurgiemechaniker-Genossenschaft · Kerrison rong DieBlauen 20cm 3mm 40° up nf we · Class 1
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 04046826404338), received between Mar 4, 2026 and Apr 21, 2026 — classified as 3 malfunctions.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Appropriate Device Problem Term/Code Not Available2
Patient problems
- Bone Fracture(s)2
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 21, 2026Appropriate Device Problem Term/Code Not Available
DESCRIBE THE EVENT OR PROBLEM: FROM STAFF: WHILE PERFORMING PART OF THE PATIENT'S SPINAL SURGERY, THE TIP OF THE INSTRUMENT BEING USED (SPIKELESS KERRISON 3) BROKE OFF. NO EVIDENT HARM OCCURRED; THE BROKEN PIECE OF THE INSTRUMENT WAS EASILY RECOVERED FROM THE PATIENT. WHAT WAS THE ORIGINAL INTENDED PROCEDURE? T11 THROUGH L4 INSTRUMENTED POSTERIOR SPINAL FUSION WITH NAVIGATION. L2 LAMINECTOMY FOR DECOMPRESSION OF SPINAL CORD. USE OF NEURO MONITORING. WHAT PROBLEM DID THE USER HAVE: DEVICE FAILED (E.G. BROKE, COULDN'T GET IT TO WORK OR STOPPED WORKING); DEVICE MALFUNCTION - THAT IS, THE DEVICE DID NOT DO WHAT IT WAS SUPPOSED TO DO. THERAPIES BEING USED ON THE PATIENT AT THE TIME OF THE EVENT THAT MAY HAVE CAUSED OR CONTRIBUTED TO THE EVENT: NOT KNOWN.
Patient problems: Bone Fracture(s)
MAUDE report 24938171 ↗MalfunctionMar 31, 2026Appropriate Device Problem Term/Code Not Available
Patient problems: Bone Fracture(s)
MAUDE report 24739835 ↗MalfunctionMar 4, 2026
FROM STAFF: WHILE PERFORMING PART OF THE PATIENT'S SPINAL SURGERY, THE TIP OF THE INSTRUMENT BEING USED (SPIKELESS KERRISON 3) BROKE OFF. NO EVIDENT HARM OCCURRED; THE BROKEN PIECE OF THE INSTRUMENT WAS EASILY RECOVERED FROM THE PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24505657 ↗
FDA clearance and classification
The FDA regulates product code HTX (rongeur) under 21 CFR 888.4540 as a Class I device. 21 CFR 888.4540 ↗
Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the Medicon 57.28.33
Has the Medicon 57.28.33 been recalled?
No FDA recall record in our data names this exact device identifier (DI 04046826404338), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the Medicon 57.28.33?
The FDA's MAUDE database lists 3 adverse event reports for this device, received between Mar 4, 2026 and Apr 21, 2026. In those reports, the most common patient problem is “Bone Fracture(s)” (2). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Medicon 57.28.33?
None of the reports are classified as deaths, 0 as injuries and 3 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the Medicon 57.28.33 FDA approved?
Devices of this type (product code HTX) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Medicon eG. Chirurgiemechaniker-Genossenschaft.
Who makes the Medicon 57.28.33, and is it still sold?
The FDA's device database lists Medicon eG. Chirurgiemechaniker-Genossenschaft as the company responsible for it (brand Medicon, model 57.28.33). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other RONGEUR devices
- SPOTLIGHT 292904201Depuy Spine, LLC · RONGEUR6 reports
- Symmetry RapidClean® 58-3200J-BDAspen Surgical Products, Inc. · Rongeur5 reports
- SPOTLIGHT 292904202Medos International Sàrl · RONGEUR5 reports
- NA 03.605.001Synthes GmbH · RONGEUR4 reports
- Symmetry Rapidclean® 58-3200-BDAspen Surgical Products, Inc. · Rongeur3 reports
- AESCULAP FF805RAesculap AG · RONGEUR3 reports
- SPOTLIGHT 292902240Depuy Spine, LLC · RONGEUR3 reports
- PIPELINE 288205041Depuy Spine, LLC · RONGEUR2 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page