Skip to content

Combined Spinal & Epidural 333197Recalls & reported problems

B. Braun Medical Inc. · PERIFIX® 17 Ga. x 3-1/2 in. Tuohy, PENCAN® 27 Ga. x 5 in. Pencil-Point Spinal Needle, PERIFIX® FX 19 Ga. Springwound Open Tip, 5 mL Glass Luer Slip LOR Tray (Kit) · Class 2

All models of Combined Spinal & Epidural (3)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Adverse event reports
3
Deaths reported
0
Injuries reported
0
Recalls naming it
1

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 04046964179327), received between Nov 18, 2019 and Nov 12, 2025 — classified as 3 malfunctions.

The most frequently reported specific device problem is “Break” (3 reports).

1 FDA recall record name this device's identifier, 1 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 1 reportsOct 2025: 0 reportsNov 2025: 1 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. Sep 18, 2025Class IIOpen, Classified

    Potential for the lid of the catheter connector to be in the incorrect position.

    Z-0123-2026 · Root cause: Process control · Recall details · FDA record ↗

Most reported problems

Device problems

  • Break3

Patient problems

  • Foreign Body In Patient2
  • Discomfort1
  • Needle Stick/Puncture1
  • No Clinical Signs, Symptoms or Conditions1
  • Pain1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • MalfunctionNov 12, 2025Break; Break

    AS REPORTED BY THE USER FACILITY: REASON OF COMPLAINT: FX CATHETERS ARE KINKING, BEING STRETCHED TOO FAR AND SNAPPING OFF. NO INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23534584 ↗
  • MalfunctionSep 11, 2025Break; Break

    AS REPORTED BY THE USER FACILITY: BRIEF INQUIRY DESCRIPTION: CATHETER METAL COIL EXPOSED, AND SOME LEFT IN PATIENT CAUSING DISCOMFORT. DETAILED INQUIRY DESCRIPTION: DURAL PUNCTURE MADE WITH 27 GUAGE NEEDLE. PT FELT RIGHT SIDED DISCOMFORT/PAIN IN RIGHT HIP BUT DID NOT DESCRIBE AS PARESTHESIA. PAIN WENT AWAY WITH SPINAL NEEDLE REMOVAL. UPON THREADING THE EPIDURAL CATHETER (WENT IN SMOOTH) PT FELT THE SAME DISCOMFORT ON THE RIGHT SIDE. WENT THROUGH STANDARD PROCESS OF REMOVING EPIDURAL FOR REPLACEMENT. AFTER NEEDLE REMOVED BEGAN PULLING BACK CATHETER AND MET A LITTLE RESISTANCE. WITH GENTLE STEADY TRACTION, THE CATHETER WAS SLIDING BACK EASILY BUT FOUND TO BE SEVERED AT APPROXIMATELY THE 5CM MARK WITH THE MENTAL INTER COIL STILL INTACT. SLOW TRACTION APPLIED TO THE METAL COIL WAS BEING USED TO GENTLY REMOVE AS MUCH AS POSSIBLE. AFTER MOST OF THE MENTAL COIL WAS REMOVED IT DID BREAK, LEAVING AN UNKNOWN AMOUNT STILL IN THE BACK.

    Patient problems: Discomfort; Foreign Body In Patient; Pain

    MAUDE report 23026803 ↗
  • MalfunctionNov 18, 2019Break; Break

    AS REPORTED BY THE USER FACILITY: IT WAS REPORTED THAT THE PATIENT WAS UNDERGOING THORACOTOMY FOR DIAPHRAGMATIC HERNIA REPAIR ON (B)(6) 2019. PATIENT RECEIVED AN THORACIC EPIDURAL AND WAS TAPED TO THE PATIENT'S BACK. PATIENT WAS MOVED FROM STRETCHER TO OR BED AND PROVIDER NOTICED THE CATHETER HAD COMPLETED SHEARED OFF IN HALF. THE CAUSE OF THE CATHETER SHEARING APPEARS TO HAVE BEEN SOME TENSION PLACED ON CATHETER AS THE PATIENT WAS MOVING. HALF OF THE CATHETER WAS STILL INSIDE THE PATIENT TAPED TO HER BACK. AS THIS IS A PAINFUL PROCEDURE, THE PATIENT NEEDED A PAIN CONTROL MODALITY BESIDE IV NARCOTICS AND AS PATIENT HAD JUST RECEIVE PREOPERATIVE HEPARIN, ANOTHER EPIDURAL WAS UNABLE TO BE PLACED. PATIENT RECEIVED POST OP TRUNCAL NERVE BLOCK (AN ADDITIONAL INVASIVE PROCEDURE).

    Patient problems: Foreign Body In Patient; Needle Stick/Puncture

    MAUDE report 9335004 ↗