Outlook® 375196Recalls & reported problems
B. Braun Medical Inc. · Outlook Pump Sets w/ ULTRASITE Needle-Free Injection Sites · Class 2
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 04046964183034), received between Nov 21, 2016 and Sep 20, 2017 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Fluid/Blood Leak” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Fluid/Blood Leak2
- Device Operates Differently Than Expected1
Patient problems
- No Consequences Or Impact To Patient3
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 20, 2017Fluid/Blood Leak; Fluid/Blood Leak
AS REPORTED BY THE USER FACILITY: EVENT 2: OUTLOOK IV SET DETACHED FROM THE MIDDLE Y-SITE DURING AN INFUSION. PUMP WAS INFUSING NORMAL SALINE SOLUTION AT A KVO (KEEP VEIN OPEN) RATE. NURSE WALKED INTO PATIENTS ROOM AND NOTICED THE IV TUBING DETACHED AT THE MIDDLE OF THE Y-SITE. PATIENT'S BLOOD WAS BACKING UP INTO THE TUBING AND A PUDDLE OF FLUID AND BLOOD WAS NOTED ON THE FLOOR. IV INFUSION WAS STOPPED AND IV SITE WAS CAPPED. NO FURTHER INTERVENTION NEEDED. CUSTOMER STATED THIS IS THE SECOND TIME THE INCIDENT HAPPENED WITHIN A WEEK. NO INJURIES REPORTED. CUSTOMER REPORTS 3 POTENTIAL LOT NUMBERS IN THE FACILITY THAT COULD BE RELATED TO THE REPORTED EVENT. POTENTIAL LOT NUMBER: 0061557903, 0061546965, 0061559982.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 6878946 ↗MalfunctionSep 20, 2017Fluid/Blood Leak; Fluid/Blood Leak
AS REPORTED BY THE USER FACILITY: OUTLOOK IV SET DETACHED FROM THE MIDDLE Y-SITE DURING AN INFUSION. PUMP WAS INFUSING NORMAL SALINE SOLUTION AT A KVO (KEEP VEIN OPEN) RATE. NURSE WALKED INTO PATIENTS ROOM AND NOTICED THE IV TUBING DETACHED AT THE MIDDLE OF THE Y-SITE. PATIENT'S BLOOD WAS BACKING UP INTO THE TUBING AND A PUDDLE OF FLUID AND BLOOD WAS NOTED ON THE FLOOR. IV INFUSION WAS STOPPED AND IV SITE WAS CAPPED. NO FURTHER INTERVENTION NEEDED. CUSTOMER STATED THIS IS THE SECOND TIME THE INCIDENT HAPPENED WITHIN A WEEK. NO INJURIES REPORTED. CUSTOMER REPORTS 3 POTENTIAL LOT NUMBERS IN THE FACILITY THAT COULD BE RELATED TO THE REPORTED EVENT. POTENTIAL LOT NUMBER: 0061557903, 0061546965, 0061559982.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 6878943 ↗MalfunctionNov 21, 2016Device Operates Differently Than Expected; Device Operates Differently Than Expected
AS REPORTED BY THE USER FACILITY: REPORTS THE PUMP ALARMS AIR IN LINE MULTIPLE TIMES. THE NURSES TRY TO RE-PRIME THE LINE, BUT PUMP CONTINUES TO ALARM FOR AIR IN LINE. UPON INSPECTION OF THE TUBING SET, A SMALL HOLE WAS OBSERVED NEAR THE METAL PUMP SEGMENT AND LEAKAGE WAS NOTED. ANTIBIOTIC MEDICATION WAS BEING INFUSED AT THE TIME. THE PATIENT DID NOT RECEIVE THE TOTAL DOSE AND WAS EXPOSED TO AIR IN LINE. ONCE THE TUBING WAS CHANGED, THERE WERE NO FURTHER AIR IN LINE ALARMS OR LEAKAGE THERE WERE NO PATIENT INJURIES.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 6118063 ↗
Other Set, administration, intravascular devices
- Autosoft XC 1001680Unomedical A/S · Set, Administration, Intravascular1 death16,105 reports
- Autosoft90™ 1002817Unomedical A/S · Set, Administration, Intravascular1 recall11,907 reports
- Minimed™ Quick-set™ MMT-399AUnomedical A/S · Set, Administration, Intravascular9 deaths8,669 reports
- Medtronic Extended MMT-431AUnomedical A/S · Set, Administration, Intravascular3 deaths8,574 reports
- MiniMed™ Mio™ Advance MMT-242AUnomedical A/S · Set, Administration, Intravascular15 deaths8,164 reports
- CADD 21-7302-24Icu Medical, Inc. · Set, administration, intravascular4 recalls1 death4,657 reports
- Autosoft XC 1001681Unomedical A/S · Set, Administration, Intravascular1 death4,216 reports
- Minimed™ Quick-set™ MMT-397AUnomedical A/S · Set, Administration, Intravascular19 deaths4,134 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page