CP Stent™ 614307Recalls & reported problems
B Braun Interventional Systems, Inc · COVERED CP STENT 8Z 2.2CM · Class 3 · Implant
All models of CP Stent (16)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04046964898785), received between May 22, 2017 and May 22, 2017 — classified as 1 malfunction.
The most frequently reported specific device problem is “Detachment Of Device Component” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Detachment Of Device Component1
Patient problems
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 22, 2017Detachment Of Device Component
AS REPORTED BY BRAUN: " CRIMPED ON TO BIB BALLOON, INSERTED TO SHEATH WITH THE HEMOSTASIS TOOL THE COVER CAME BACK AND ROLLED OFF. THIS HAPPENED TWO TIMES. WENT IN AND OUT OF THE HEMOSTASIS VALVE MULTIPLE TIMES PHYSICIAN RE-CRIMPED IT. ACCOUNT SAID IT COULD BE OPERATOR ERROR, PHYSICIAN'S FIRST TIME USING STENT UNAIDED. AS STENT WAS ADVANCING THROUGH, IT KEPT COMING OFF OF THE BALLOON. THERE WAS NO DIFFICULTY MOUNTING THE BALLOON. THE SIZE OF THE CATHETER THE STENT WAS MOUNTED ON: 16 MM X 4.5 CM BOTH, 2.2 STENT 3.4 STENT. BOTH SALINE AND CONTRAST MEDIA WERE USED DURING PREP. THE HEMOSTASIS TOOLS WERE USED THAT ARE PROVIDED BY NUMED - THE SIZES: 16 AND 18. THE STENT STARTED SLIPPING DURING INSERTION THROUGH THE SHEATH. THE INNER BALLOON WAS INFLATED BEFORE THE OUTER BALLOON ONCE THE 2 SUCCESSFUL STENTS WERE DEPLOYED. THEY ATTEMPTED TO PULL THE STENT BACK THROUGH THE HEMOSTASIS VALVE TO GET IT OUT. CRIMPING PROCESS USED: RING MANDRIL THROUGH END OF BALLOON WITH STENT ON IT, PUT IT IN BETWEEN MARKERS (2 OUTER IMAGE BANDS) COMPRESSED WITH THUMB AND INDEX ROLLED IT. USED UMBILICAL TAPE TO WRAP AROUND STENT AND FURTHER CRIMP DOWN. THE INDICATION THE PHYSICIAN WAS USING THE BALLOON FOR - C
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6581063 ↗
FDA clearance and classification
Approved through premarket approval (PMA) P150028 on Mar 25, 2016. Submitted by NuMED, Inc. as “CHEATHAM PLATINUM (CP) STENT SYSTEM (Covered CP Stent, Covered Mounted CP Stent, CP Stent, Mounted CP Stent)”. The FDA review took 233 days. The FDA has since approved 7 supplements (changes to the device or its labeling), most recently on Jul 6, 2026. FDA record ↗
Devices of this type need premarket approval (PMA), the FDA's most demanding review, usually with clinical data.
The FDA lists this type of device as life-sustaining or life-supporting.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the CP Stent™ 614307
Has the CP Stent™ 614307 been recalled?
No FDA recall record in our data names this exact device identifier (DI 04046964898785), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the CP Stent™ 614307?
The FDA's MAUDE database lists 1 adverse event report for this device, received on May 22, 2017. That report lists device problem “Detachment Of Device Component” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the CP Stent™ 614307?
None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the CP Stent™ 614307 FDA approved?
It was approved through premarket approval (PMA) P150028 on Mar 25, 2016.
Is the CP Stent™ 614307 MRI safe?
According to the device's FDA GUDID record, its labeling lists it as MR Conditional: it can be scanned only under the specific conditions given in the labeling. The radiology team should check those conditions before an MRI.
Who makes the CP Stent™ 614307, and is it still sold?
The FDA's device database lists B Braun Interventional Systems, Inc as the company responsible for it (brand CP Stent™, model 614307). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Aortic stent devices
- Minima Stent System - 6mm FG-0001Renata Medical, Inc. · Aortic Stent1 death9 reports
- CP Stent™ 614311B Braun Interventional Systems, Inc · Aortic stent6 reports
- CP Stent™ 614310B Braun Interventional Systems, Inc · Aortic stent3 reports
- CP Stent™ 614309B Braun Interventional Systems, Inc · Aortic stent3 reports
- CP Stent™ 614308B Braun Interventional Systems, Inc · Aortic stent3 reports
- CP Stent™ 614516B Braun Interventional Systems, Inc · Aortic stent2 reports
- CP Stent™ 614376B Braun Interventional Systems, Inc · Aortic stent2 reports
- CP Stent™ 614367B Braun Interventional Systems, Inc · Aortic stent1 report
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page