CP Stent™ 614371Recalls & reported problems

B Braun Interventional Systems, Inc · CMCP022 Mounted Covered CP Stent 3.9 24 · Class 3 · Implant

Data updated Oct 13, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04046964899515), received between Mar 11, 2021 and Mar 11, 2021 — classified as 1 malfunction.

The most frequently reported specific device problem is “Difficult to Advance” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Most reported problems

Device problems

  • Difficult to Advance1
  • Improper or Incorrect Procedure or Method1
  • Malposition of Device1
  • Material Split, Cut or Torn1

Patient problems

  • Insufficient Information1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 11, 2021Improper or Incorrect Procedure or Method; Malposition of Device; Difficult to Advance; Material Split, Cut or Torn

    AS PER THE REPORT FROM THE DISTRIBUTOR / USER FACILITY - 14 FR D'VILL SHEATH IN RVOT, LUNDERQUIST WIRE, DIFFICULTY PASSING THE BALLOON STENT COMBO THOUGH THE CHECK FLOW VALVE, WITHOUT PROTECTOR. BEFORE THE STENT BALLOON COMBO EXITED THE DISTAL END OF THE SHEATH, A MAL-POSITION OF THE STENT ON THE BALLOON WAS NOTED. THE STENT BALLOON COMBO WAS REMOVED FROM THE SHEATH UNEVENTFULLY, ALTHOUGH A SLIGHT DAMAGE GORETEX ON THE DISTAL END OF THE STENT WAS NOTED. ON THE BACK TABLE THE BALLOON USED TO EXPAND THE STENT RESULTED IN FURTHER TEAR OF GORETEX WITH ONLY ABOUT 1/3 OF THE STENT COVERED AFTER EXPANSION. THE INDICATION THE PHYSICIAN WAS USING THE PRODUCT FOR WAS CONDUIT REHABILITATION PRIOR TO TPVR. THE BLUE INTRODUCER TOOL PROVIDED BY NUMED WAS NOT USED. THERE WAS AN ATTEMPT TO PULL THE STENT BACK THROUGH THE HEMOSTASIS VALVE. NEITHER BALLOON WAS INFLATED IN THE PATIENT, ON THE BACK TABLE THE INNER WAS INFLATED FIRST. THE CATHETER SHAFT WAS NOT KINKED.

    Patient problems: Insufficient Information

    MAUDE report 11466588 ↗