SPROTTE® 021151-29A (UDI 04048223103838)Recalls & reported problems
Pajunk GmbH Medizintechnologie · Distal Tip: SPROTTE® Proximal End: ISO 80369-7 · Class 2
All models of SPROTTE (30)
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04048223103838), received between Jun 21, 2021 and Jun 21, 2021 — classified as 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Break1
Patient problems
- Insufficient Information1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 21, 2021Break; Break
IRN# (B)(4). TENTATIVE SUMMARIZING TRANSLATION FROM INITIAL REPORTER¿S NARRATIVE: "WOMAN PLANNED FOR ELECTIVE CESAREAN SECTION. BMI 38 (AT THE BEGINNING OF PREGNANCY), 150CM LONG, SHARPLY SWAYING BACK. SPINAL ANESTHESIA IN A SITTING POSITION WITH AN ANGLED OPERATING TABLE TO OPTIMIZE THAT THE PATIENT BENDS HIS BACK. DIFFICULT TO PALPATE VERTEBRAE DUE TO OBESITY AND DUMB, STRONG SKIN. INTRODUCER IS INTRODUCED WITHOUT REMARK. INTRODUCTION OF SPINAL SPROTTE PENCIL POINT 25G, 90MM TAKES PLACE AGAINST SLIGHTLY ELEVATED BUT CONSTANT RESISTANCE, GETS A "LOOSE" AND REMOVES THE MANDREL TO SEE IF LIQUOR EXCHANGE, WHICH DOES NOT HAPPEN. INSERT THE MANDREL AGAIN AND INSERT THE SPINAL NEEDLE FURTHER, THE SAME RESISTANCE AND NOW BOTTOMS WITH THE NEEDLE IN ITS FULL LENGTH BUT FEEL AS A CONTACT IN DEPTH AS IN BONE CONTACT. REMOVES MANDRANG AGAIN AND LOOKS FOR LIQUORS, NO BACKFLOW. THE NEEDLE GENTLY REVERSES WHILE CHECKING FOR LIQUIDS. THE SAME TOUGH, CONSTANT RESISTANCE AS WITH THE INSERTION AND WHEN BACKED 0.5-1 CM, THE RESISTANCE SUDDENLY RELEASES AND THE SPINAL NEEDLE BRAKES INSIDE THE PATIENT'S BACK. HAS CONTACT WITH THE REMAINING NEEDLE PIECES IN THE INTRODUCER, UNCLEAR WHETHER IN THE LUMEN O
Patient problems: Insufficient Information
MAUDE report 12030754 ↗
FDA clearance and classification
The FDA regulates product code BSP (needle, conduction, anesthetic (w/wo introducer)) under 21 CFR 868.5150 as a Class II device. 21 CFR 868.5150 ↗
Devices of this type normally need 510(k) clearance before sale.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the SPROTTE® 021151-29A
Has the SPROTTE® 021151-29A been recalled?
No FDA recall record in our data names this exact device identifier (DI 04048223103838), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the SPROTTE® 021151-29A?
The FDA's MAUDE database lists 1 adverse event report for this device, received on Jun 21, 2021. That report lists device problem “Break” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the SPROTTE® 021151-29A?
None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Who makes the SPROTTE® 021151-29A, and is it still sold?
The FDA's device database lists Pajunk GmbH Medizintechnologie as the company responsible for it (brand SPROTTE®, model 021151-29A). Its record shows it as no longer in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other NEEDLE, CONDUCTION, ANESTHETIC (W/WO INTRODUCER) devices
- ARROW IPN922632Teleflex Incorporated · NEEDLE, CONDUCTION, ANESTHETIC (W/WO INTRODUCER)2 recalls0 reports
- ARROW IPN922605Teleflex Incorporated · NEEDLE, CONDUCTION, ANESTHETIC (W/WO INTRODUCER)1 recall0 reports
- ARROW IPN922603Teleflex Incorporated · NEEDLE, CONDUCTION, ANESTHETIC (W/WO INTRODUCER)1 recall0 reports
- ARROW IPN922604Teleflex Incorporated · NEEDLE, CONDUCTION, ANESTHETIC (W/WO INTRODUCER)1 recall0 reports
- ARROW IPN922631Teleflex Incorporated · NEEDLE, CONDUCTION, ANESTHETIC (W/WO INTRODUCER)1 recall0 reports
- ARROW IPN923597Teleflex Incorporated · NEEDLE, CONDUCTION, ANESTHETIC (W/WO INTRODUCER)1 recall0 reports
- 22G 1 1/2IN Regional Block Needle 408348Becton, Dickinson And Company · NEEDLE, CONDUCTION, ANESTHETIC (W/WO INTRODUCER)1 recall0 reports
- BD QUINCKE Spinal Needles 405180Becton, Dickinson And Company · NEEDLE, CONDUCTION, ANESTHETIC (W/WO INTRODUCER)23 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page