Skip to content

n.a. 11003MARecalls & reported problems

Karl Storz GmbH & Co. KG · Biopsy Forceps, flexible, 1 mm · Class 2

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 04048551050248), received between Jul 16, 2025 and Jul 16, 2025 — classified as 2 injuries.

The most frequently reported specific device problem is “Mechanical Problem” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 2 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Mechanical Problem2

Patient problems

  • No Clinical Signs, Symptoms or Conditions2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryJul 16, 2025Mechanical Problem; Mechanical Problem

    THE FOLLOWING WAS REPORTED, WHILE ATTEMPTING TO PERFORM A TRACHEOBRONCHIAL MUCOSAL BIOPSY, THE FORCEPS LOST ITS MOVEMENT, MAKING ITS USE IMPOSSIBLE. THE PROCEDURE WAS CANCELED. NO NEGATIVE IMPACT IN STATE OF HEALTH REPORTED. DUE TO THE PROLONGATION OF THE PROCEDURE LONGER THAN 60 MINUTES AND THE CANCELED PROCEDURE THE EVENT IS DEEMED REPORTABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22524217 ↗
  • InjuryJul 16, 2025Mechanical Problem; Mechanical Problem

    THE FOLLOWING WAS REPORTED; WHILE ATTEMPTING TO PERFORM A TRACHEOBRONCHIAL MUCOSAL BIOPSY, THE FORCEPS LOST ITS MOVEMENT, MAKING ITS USE IMPOSSIBLE. THE PROCEDURE WAS CANCELED. NO NEGATIVE IMPACT IN STATE OF HEALTH REPORTED. DUE TO THE PROLONGATION OF THE PROCEDURE LONGER THAN 60 MINUTES AND THE CANCELED PROCEDURE THE EVENT IS DEEMED REPORTABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22524215 ↗

Other BRONCHOSCOPE (FLEXIBLE OR RIGID) devices

All BRONCHOSCOPE (FLEXIBLE OR RIGID) devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page