IOLMaster 500Recalls & reported problems
Carl Zeiss Meditec AG · The IOLMaster is intended for the biometric determination of ocular measurements for axial length, anterior chamber depth, corneal radius, white-to-white (WTW), and for the measurement of pupil size and deviation of the visual axis from the center of the pupil. For patients who are candidates for intraocular lens (IOL) implantation, the device also performs calculations to assist physicians in determining the appropriate IOL power and type for implantation. · Class 2
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04049471092066), received between Apr 15, 2022 and Apr 15, 2022 — classified as 1 injury.
The most frequently reported specific device problem is “Use of Device Problem” (1 report).
4 other recalls cover devices cleared under the same FDA submission (K122418, K141068); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Use of Device Problem1
Patient problems
- Visual Impairment1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryApr 15, 2022Use of Device Problem; Use of Device Problem
A HEALTH CARE PROFESSIONAL (HCP) REPORTED THAT THE AXIAL LENGTH USED FOR IOL CALCULATION WAS NOT THE AXIAL LENGTH THAT WAS MEASURED BY THE IOLMASTER 500. THE ISSUE WAS NOT CAUGHT PRIOR TO SURGERY AND A REFRACTIVE SURPRISE ON THE PATIENT'S RIGHT EYE OCCURRED. THE DOCTOR REPORTED THAT HE HAD IMPLANTED THE WRONG LENS INTO THE PATIENT'S EYE. THE PATIENT IS NOW NEAR SIDED. THE DOCTOR REPORTED THAT HE IS PLANNING TO EXPLANT THE LENS.
Patient problems: Visual Impairment
MAUDE report 14118811 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K122418, K141068. One submission often covers many models, so check the product and lot details in each record.
- Z-0358-2016 · Oct 27, 2015 · TerminatedIOL Master 500: Software versions 7.5 and 7.7; Ophthalmic: IOL Master 500 is intended for biometric determination of ocular measurements of axial length, anterior chamber depth, c
- Z-0357-2016 · Oct 27, 2015 · TerminatedIOL Master 5.5: Software versions 7.5 and 7.7; Ophthalmic: used to obtain ocular measurements and perform calculations to allow physicians to determine appropriate IOL power and t
- Z-0333-2014 · Oct 23, 2013 · TerminatedZeiss brand IOLMaster, Version 1-5, Biomicroscope, Slit-Lamp, AC-Powered, Product is manufactured by Carl Zeiss Meditec AG (Jena), Carl Zeiss Promenade 10, Jena, Germany 07745; a
- Z-0334-2014 · Oct 23, 2013 · TerminatedZeiss brand IOLMaster 500, Model 500, Biomicroscope, Slit-Lamp, AC-Powered, Product is manufactured by Carl Zeiss Meditec AG (Jena), Carl Zeiss Promenade 10, Jena, Germany 07745;
Other Biomicroscope, Slit-Lamp, Ac-Powered devices
- IOLMaster 700Carl Zeiss Meditec AG · Biomicroscope, Slit-Lamp, Ac-Powered1 recall50 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page