1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04057834028720), received between Apr 8, 2026 and Apr 8, 2026 — classified as 1 injury.

The most frequently reported specific device problem is “Material Deformation” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 1 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Material Deformation1
  • No Device Output1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryApr 8, 2026No Device Output; Material Deformation

    FROM OUR DISTRIBUTOR WE RECEIVED THE FOLLOWING DESCRIPTION OF AN EVENT TO ONE OF OUR CATHETER NEUROVENT-PTO ON (B)(6) 2026 AT (B)(6) HOSPITAL: "AS CATHETER WAS BEING PLACED IN PATIENT, IT COILED AND WAS NON-FUNCTIONAL. SUNY REPORTED THE INCIDENT THROUGH THEIR RECALLS TEAM WHO REPORTS TO ECRI." FOLLOW-UP INFORMATIONS WERE RECEIVED ON (B)(6) 2026 AND (B)(6) 2026: "DR. (B)(6) PLACED RAUMEDIC DRAIN IN PATIENT. UPON INSERTION ELEVATED ICPS WERE NOTED THEREFORE PATIENT REQUIRED MULTIPLE INTERVENTIONS TO HELP BRING ICPS DOWN. ON THE POST PROCEDURE CT THE CATHETER APPEARED TO BE "SQUIGGLED"/"COILED" PER DR. (B)(6). EVD WAS THEN PLACED TO CONFIRM ELEVATED ICPS WHICH DID IN FACT CONFIRM ELEVATED ICPS WERE TRUE. RAUMEDIC WAS REMOVED AND PLACED IN BIOHAZARD BAG TO BE ASSESSED AND SENT BACK TO MANUFACTURE FOR POSSIBLE DEFECT. NURSE MANAGER MADE AWARE OF THIS AS WELL." "BASED ON THE NOTES IT APPEARS THE EVD WAS PLACED LATER THAT NIGHT, NOT AT THE SAME TIME. RAUMEDIC WAS REMOVED AND REPLACED WITH EVD. THEY BELIEVED IT WAS NON-FUNCTIONAL BECAUSE THE ICP'S WERE SO HIGH. THEY DID GET A READING, SO THERE WAS FUNCTION JUST CONCERN WITH ACCURACY. RAUMEDIC WAS PLACED, NOTED TO HAVE HIGH ICP'S GREATER TH

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24813025 ↗

Other Device, Monitoring, Intracranial Pressure devices