Skip to content

REXEED 21SRecalls & reported problems

Asahikasei Medical Mt K.K. · Intended for use in hemodialysis for the treatment of patients suffering from acute or chronic renal failure. · Class 2

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04537693003910), received between Oct 6, 2020 and Oct 6, 2020 — classified as 1 malfunction.

The most frequently reported specific device problem is “Fluid/Blood Leak” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Fluid/Blood Leak1

Patient problems

  • No Consequences Or Impact To Patient1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionOct 6, 2020Fluid/Blood Leak; Fluid/Blood Leak

    DIALYZER CRACKED 30 MINUTES AFTER STARTING THE TREATMENT WITH BLOOD FLOW RATE AT 450 ML/MIN, AND DIALYSATE FLOW RATE AT 800 ML/MIN. EXTERNAL BLOOD LEAKAGE WAS FOUND FROM THE ARTERIAL, AND VENOUS HEADERS BY VISUAL OBSERVATION. APPROXIMATE BLOOD VOLUME LOSS WAS 50 ML. THE PATIENT WAS STABLE AND DID NOT NEED ANY MEDICAL INTERVENTION. DIALYZERS WITH SAME LOT NUMBER WERE USED WITH NO PROBLEM.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 10633148 ↗

FDA clearance and classification

The FDA regulates product code KDI (dialyzer, high permeability with or without sealed dialysate system) under 21 CFR 876.5860 as a Class II device. 21 CFR 876.5860 ↗

Devices of this type normally need 510(k) clearance before sale.

The FDA lists this type of device as life-sustaining or life-supporting.

Common questions about the REXEED 21S

Has the REXEED 21S been recalled?

No FDA recall record in our data names this exact device identifier (DI 04537693003910), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the REXEED 21S?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Oct 6, 2020. That report lists device problem “Fluid/Blood Leak” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the REXEED 21S?

None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Who makes the REXEED 21S, and is it still sold?

The FDA's device database lists Asahikasei Medical Mt K.K. as the company responsible for it (brand REXEED, model 21S). Its record shows it as no longer in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Dialyzer, High Permeability With Or Without Sealed Dialysate System devices

All Dialyzer, High Permeability With Or Without Sealed Dialysate System devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page