REXEED 25SRecalls & reported problems
Asahikasei Medical Mt K.K. · Intended for use in hemodialysis for the treatment of patients suffering from acute or chronic renal failure. · Class 2
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 04537693003927), received between Jul 19, 2018 and Jan 23, 2020 — classified as 1 injury, 4 malfunctions.
The most frequently reported specific device problem is “Fluid/Blood Leak” (5 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Fluid/Blood Leak5
Patient problems
- No Known Impact Or Consequence To Patient3
- Dyspnea1
- No Code Available1
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
MalfunctionJan 23, 2020Fluid/Blood Leak; Fluid/Blood Leak
ON (B)(6) 2019, THIS PATIENT STARTED THE TREATMENT WITH DIALYZER, REXEED-25S. AFTER 30 MINUTES FROM THE BEGINNING OF THE TREATMENT, ONE SIDE OF THE ARTERIAL HEADER OF THE DIALYZER HOUSING LIFTED UP, AND THE BLOOD STARTED COMING OUT OF THE DIALYZER. THEREFORE, THE PATIENT'S TREATMENT NEEDED TO BE STOPPED URGENTLY. ALL BLOOD IN THE CIRCUIT WAS UNABLE TO BE RETURNED TO THE PATIENT. THE VOLUME OF THE PATIENT'S BLOOD LOSS WAS ABOUT 230 ML.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 9619907 ↗MalfunctionApr 18, 2019Fluid/Blood Leak; Fluid/Blood Leak
(B)(6) 2019, THIS EVENT OCCURRED DURING THE TREATMENT WITH REXEED-25S. THIS CLINIC PRIMED WITH 1000 ML OF NORMAL SALINE AND RECIRCULATED THE DIALYZER FOR ABOUT 5 MINUTES. AFTER 90 MINUTES FROM THE TREATMENT START, THE VENOUS PRESSURE ALARMED, AND THEN THE BLOOD LEAK FROM THE ARTERIAL HEADER OCCURRED. AFTER THIS EVENT, THIS PATIENT'S CONDITION WAS STABLE, AND THE PATIENT DID NOT REQUIRE MEDICAL ATTENTION, THERE WAS NEITHER NEED FOR BLOOD TRANSFUSION NOR FOR ADJUSTING ERYTHROPOIETIN(EPO) DOSAGE. THE PATIENT LEFT THE DIALYSIS ROOM IN STABLE CONDITION.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8525800 ↗InjuryNov 8, 2018Fluid/Blood Leak; Fluid/Blood Leak
PATIENT WAS IN OUTPATIENT DIALYSIS UNIT FOR REGULARLY SCHEDULED DIALYSIS TREATMENT 3 DAYS A WEEK. PATIENT WAS PRESCRIBED A TREATMENT LENGTH OF 4 HR 15 MINUTES. DIALYSATE FLOW RATE WAS 800 ML/MIN AND DIALYSATE TEMPERATURE 36 C. PATIENT'S DRY WEIGHT WAS (B)(6), HE WAS SET FOR A TARGET LOSS OF 3.4 KG. ON (B)(6) 2018, 06:55, DIALYSIS OF REXEED-25S WAS INITIATED. ON (B)(6) 2018, APPROXIMATELY 07:25, PATIENT'S ALARM ON MACHINE STARTED SOUNDING WITH AN ARTERIAL PRESSURE ALARM. NURSE WENT OVER TO MACHINE, AND IT APPEARED THAT BLOOD AND LIQUID WAS COMING OUT OF THE ARTERIAL HANSEN DRIPPING ONTO TO FLOOR (HIS APPROXIMATE BLOOD VOLUME LOSS: ROUGHLY 100 CC). PUMP WAS STOPPED, AND PATIENT WAS DISCONNECTED. RINSE BACK WAS NOT GIVEN. MACHINE WAS CHANGED OUT. THE PATIENT'S HEALTH CONDITION WAS STABLE, AND DID NOT NEED ANY MEDICAL INTERVENTIONS.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8050028 ↗MalfunctionAug 29, 2018Fluid/Blood Leak; Fluid/Blood Leak
ON (B)(6), 2018, THE PATIENT WAS GIVEN THE TREATMENT WITH HEMODIALYSIS (HD) USING REXEED-25S. AT 12:15 PM, THE TREATMENT WAS STARTED. THE PATIENT WAS VERY RESTLESS AND HAD SHORTNESS OF BREATH FROM THE BEGINNING OF HIS TREATMENT. DESPITE HIS RESTLESSNESS, HIS CATHETER WAS RUNNING WITHOUT ANY PROBLEM AND MACHINE WAS NOT FREQUENTLY ALARMING. AT 13:56 PM, THE PATIENT REQUESTED TO GET OUT OF HIS BED AND TRANSFER TO THE DIALYSIS CHAIR SO THE NURSE DISCONNECTED THE PATIENT FROM THE DIALYSIS SYSTEM AND PUT THE SYSTEM INTO RECIRCULATION. AT 14:05 PM, THE MACHINE ALARMED DUE TO HIGH VENOUS PRESSURE, THE NURSE PRESSED THE RESET KEY TO RESTART THE MACHINE. UPON THE BLOOD PUMP STARTING, THE NURSE HEARD A CRACK AND BLOOD STARTED POURING OUT OF THE TOP OF THE DIALYZER. THE TREATMENT WAS STOPPED AND THE PATIENT CONTINUED TREATMENT WITH NEW PRIMED DIALYZER WITHOUT INCIDENT. PATIENT CONDITION WAS STABLE.
Patient problems: Dyspnea; No Code Available
MAUDE report 7831291 ↗MalfunctionJul 19, 2018Fluid/Blood Leak; Fluid/Blood Leak
ON (B)(6) 2018, THE PATIENT WAS GIVEN THE TREATMENT WITH HEMODIALYSIS (HD) USING REXEED-25S. A NURSE PLACED NEEDLES IN FISTULA WITHOUT PROBLEMS, AND STARTED THE TREATMENT. ARTERIAL PRESSURE ALARMED MULTIPLE TIMES APPROXIMATELY 5-7 MINUTES INTO THE TREATMENT AND THE NURSE ATTEMPTED TO ADJUST THE NEEDLE WITHOUT SUCCESS. THE NURSE STARTED TO RECIRCULATE TO TRY TO ADJUST THE NEEDLES. SINCE ARTERIAL PRESSURE ALARMED ON THE DIALYSIS MACHINE, THE NURSE DID NOT CHECK IF THE BLOOD WAS CLOTTED WHEN THE MACHINE WAS RECIRCULATED. AS SOON AS MACHINE WAS STARTED TO RECIRCULATE, BLOOD CLOTS WERE COMING OUT OF THE ARTERIAL HEAD OF THE DIALYZER. AFTER FURTHER INVESTIGATION, IT WAS DISCOVERED THAT PATIENT'S ACCESS WAS CLOTTED AND THE PATIENT WAS SENT TO INTERVENTIONAL RADIOLOGY TO REMOVE BLOOD CLOTS. PATIENT DID NOT HAVE ANY ISSUES WITH THIS INCIDENT.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7701652 ↗
FDA clearance and classification
The FDA regulates product code KDI (dialyzer, high permeability with or without sealed dialysate system) under 21 CFR 876.5860 as a Class II device. 21 CFR 876.5860 ↗
Devices of this type normally need 510(k) clearance before sale.
The FDA lists this type of device as life-sustaining or life-supporting.
Common questions about the REXEED 25S
Has the REXEED 25S been recalled?
No FDA recall record in our data names this exact device identifier (DI 04537693003927), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the REXEED 25S?
The FDA's MAUDE database lists 5 adverse event reports for this device, received between Jul 19, 2018 and Jan 23, 2020. In those reports, the most common specific device problem is “Fluid/Blood Leak” (5); the most common patient problem is “Dyspnea” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the REXEED 25S?
None of the reports are classified as deaths, 1 as an injury and 4 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Who makes the REXEED 25S, and is it still sold?
The FDA's device database lists Asahikasei Medical Mt K.K. as the company responsible for it (brand REXEED, model 25S). Its record shows it as no longer in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Dialyzer, High Permeability With Or Without Sealed Dialysate System devices
- Optiflux® 0500318EFresenius Medical Care Holdings, Inc. · Dialyzer, high permeability with or without sealed dialysate system1 recall6 deaths2,832 reports
- 2008® Series Hemodialysis Machines 190713Fresenius Usa, Inc. · Dialyzer, high permeability with or without sealed dialysate system3 recalls37 deaths893 reports
- 2008T BlueStar Hemodialysis Machine 191126Fresenius Medical Care Holdings, Inc. · Dialyzer, high permeability with or without sealed dialysate system5 recalls10 deaths439 reports
- 2008® Series Hemodialysis Machines 190766Fresenius Usa, Inc. · Dialyzer, high permeability with or without sealed dialysate system4 recalls15 deaths369 reports
- 2008T BlueStar Hemodialysis Machine 191130Fresenius Medical Care Holdings, Inc. · Dialyzer, high permeability with or without sealed dialysate system4 recalls7 deaths273 reports
- 2008® Series Hemodialysis Machines 190610Fresenius Usa, Inc. · Dialyzer, high permeability with or without sealed dialysate system1 recall15 deaths335 reports
- Optiflux® 0500320EFresenius Medical Care Holdings, Inc. · Dialyzer, high permeability with or without sealed dialysate system2 recalls239 reports
- REVACLEAR 300Gambro Renal Products, Inc. · Dialyzer, high permeability with or without sealed dialysate system3 recalls125 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page