i-ED COIL 390-01H3Recalls & reported problems

Kaneka Corporation · The i-ED COIL is used for vascular embolization with a platinum coil at the target lesion in the patient’s blood vessel. · Class 2 · Implant

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 04540778176478), received between Jun 2, 2023 and Jun 4, 2024 — classified as 3 injuries.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 1 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem3

Patient problems

  • Ruptured Aneurysm2
  • Aneurysm1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjuryJun 4, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    CASE WAS 3.39MM WIDE ANTERIOR COMMUNICATING ARTERY UNRUPTURED ANEURYSM. FIRST COIL WAS SUCCESSFULLY DEPLOYED WHICH WAS A 3X4 COMPLEX EXTRA SOFT COIL. THE SECOND COIL WAS DEPLOYED AND ABOUT TO DETACH IN THE ANEURYSM WHICH WAS A 1.5 X 3 SILK SOFT. THE CATHETER KICKED OUT IF THE ANEURYSM AND THE COIL WAS REMOVED AND SET ASIDE. NO ISSUE AT THAT TIME. THE ANEURYSM WAS THEN REENTERED WITH A 156CM HEADWAY DUO AND ADDITIONAL SUPPORT FROM THE .038 DAC MOVING DISTALLY. WHEN ENTERING THE ANEURYSM THE CATHETER DID MOVE THE ORIGINAL COIL AND THEN WE STARTED TO DEPLOY THE SECOND COIL. THE COIL WAS OUTSIDE THE ANEURYSM AND THE MD THOUGHT IT WAS THE COIL THAT CAUSED THE RUPTURE/BLEED. THE SECOND COIL REMAINED IN THE PATIENT AND THE MD THOUGHT IT WAS ENOUGH COIL TO PROTECT THE NOW RUPTURED ANEURYSM. UNFORTUNATELY, THE PATIENT HAS SOME SUBARACHNOID HEMORRHAGE (SAH) / INTRAVENTRICULAR HEMORRHAGE (IVH) AND WENT FOR EXTERNAL VENTRICULAR DRAIN (EVD). PATIENT WAS GIVEN MEDICATION.

    Patient problems: Ruptured Aneurysm

    MAUDE report 19464079 ↗
  • InjuryJun 12, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    TREATMENT OF LEFT MCA BIFURCATION ANEURYSM, PREVIOUS TREATED A YEAR AGO BY STENT ASSISTED COILING USING A "STRYKER NEUROFORM ATLAS STENT". SPACE TO BE COILED WAS 3.5MM X 2.5MM IN SIZE, BEHIND THE PREVIOUSLY PLACED STENT. "STRYKER EXCELSIOR SL10" MICROCATHETER SELECTED FOR COIL DELIVERY. MICROCATHETER TIP WAS PLACED INTO ANEURYSM THROUGH THE STENT STRUTS. 1ST COIL SELECTED WAS THE "IED COIL COMPLEX INFINI SILKYSOFT (393-020306)", DELIVERED INTO THE ANEURYSM WITHOUT COMPLICATIONS AND DEPLOYED. 2ND COIL SELECTED WAS THE "IED COIL COMPLEX SILKYSOFT (390-01H3)", DELIVERED INTO THE ANEURYSM AND POSITIONED READY FOR DEPLOYMENT. DURING A VISUAL CHECK BEFORE DEPLOYMENT, RUPTURE OF THE ANEURYSM AND CORRESPONDING HEMORRHAGE AND COIL LOOPS OUTSIDE OF THE ANEURYSM WALL INTO THE SUBDURAL SPACE CONFIRMED. CAUSE OF RUPTURE COULD NOT BE IDENTIFIED BUT NOT DIRECTLY RELATED TO COIL. AFTER HEMORRHAGE WAS CONFIRMED A FURTHER 8 IED COILS WERE DEPLOYED INTO THE SPACE TO STOP THE BLEEDING. HEMOSTASIS WAS ACHIEVED APPROXIMATELY 27MINUTES AFTER RUPTURE OF ANEURYSM. AFTER PROCEDURE AN HEMATOMA APPROXIMATELY 3CM WIDE IN SIZE WAS CONFIRMED AT THE POINT OF RUPTURE AND PATIENT WAS IN AN UNSTABLE CONDITION. ON 5/

    Patient problems: Aneurysm

    MAUDE report 17104901 ↗
  • InjuryJun 2, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    TREATMENT OF LEFT MCA BIFURCATION ANEURYSM, PREVIOUS TREATED A YEAR AGO BY STENT ASSISTED COILING USING A "STRYKER NEUROFORM ATLAS STENT". SPACE TO BE COILED WAS 3.5MM X 2.5MM IN SIZE, BEHIND THE PREVIOUSLY PLACED STENT. "STRYKER EXCELSIOR SL10" MICROCATHETER SELECTED FOR COIL DELIVERY. MICROCATHETER TIP WAS PLACED INTO ANEURYSM THROUGH THE STENT STRUTS. 1ST COIL SELECTED WAS THE "IED COIL COMPLEX INFINI SILKYSOFT (393-020306)", DELIVERED INTO THE ANEURYSM WITHOUT COMPLICATIONS AND DEPLOYED. 2ND COIL SELECTED WAS THE "IED COIL COMPLEX SILKYSOFT (390-01H3)", DELIVERED INTO THE ANEURYSM AND POSITIONED READY FOR DEPLOYMENT. DURING A VISUAL CHECK BEFORE DEPLOYMENT, RUPTURE OF THE ANEURYSM AND CORRESPONDING HEMORRHAGE AND COIL LOOPS OUTSIDE OF THE ANEURYSM WALL INTO THE SUBDURAL SPACE CONFIRMED. CAUSE OF RUPTURE COULD NOT BE IDENTIFIED BUT NOT DIRECTLY RELATED TO COIL. AFTER HEMORRHAGE WAS CONFIRMED A FURTHER 8 IED COILS WERE DEPLOYED INTO THE SPACE TO STOP THE BLEEDING. HEMOSTASIS WAS ACHIEVED APPROXIMATELY 27MINUTES AFTER RUPTURE OF ANEURYSM. AFTER PROCEDURE AN HEMATOMA APPROXIMATELY 3CM WIDE IN SIZE WAS CONFIRMED AT THE POINT OF RUPTURE AND PATIENT WAS IN AN UNSTABLE CONDITION. ON 5/

    Patient problems: Ruptured Aneurysm

    MAUDE report 17045876 ↗

Other Device, Neurovascular Embolization devices

All Device, Neurovascular Embolization devices →