T2 1822-0015SRecalls & reported problems
Stryker GmbH · End Cap · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 1
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04546540197573), received between Sep 29, 2015 and Sep 29, 2015 — classified as 1 death.
The most frequently reported specific device problem is “Fracture” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Fracture1
Patient problems
- Bone Fracture(s)1
- Death1
- Fall1
- Hemorrhage/Blood Loss/Bleeding1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
DeathSep 29, 2015Fracture
IT WAS REPORTED BY THE PATIENT'S DAUGHTER THAT THE PATIENT WENT INTO VA HOSPITAL FOR A COUMADIN APPOINTMENT AND DUE TO BLEEDING COMPLICATIONS PATIENT WAS TRANSFERRED TO A NON-VA HOSPITAL. THEY TRIED TO RECOVER HIM FROM THAT ISSUE, GIVING HIM BLOOD TRANSFUSION AND FRESH FROZEN PLASMA. PATIENT WAS PUT IN ICU. ON THIRD NIGHT, IN WEE HOURS OF THE MORNING, PATIENT FELL OUT OF BED. RAILS WERE RAISED. PATIENT FELL ON 20TH [MONTH UNKNOWN]. PATIENT BROKE HIS HIP AND HIS SHOULDER. SURGERY OCCURRED ON THE 23RD [MONTH UNKNOWN]. HIP ONLY SURGERY. SURGERY WAS COMPLETED SUCCESSFULLY. PATIENT PASSED AWAY FOUR DAYS AFTERWARDS. NO AUTOPSY PERFORMED.
Patient problems: Bone Fracture(s); Death; Fall; Hemorrhage/Blood Loss/Bleeding
MAUDE report 5110695 ↗
Other ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES devices
- NA 03.033.001Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES265 reports
- GAMMA 3125-1180SStryker GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES249 reports
- NA 03.037.026Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES225 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-075Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls2 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-045Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- PRECICE® Intramedullary Limb Lengthening System LSC5-050Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- TRIGEN 71674067Smith & Nephew, Inc. · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES201 reports
- PRECICE Intramedullary Limb Lengthening System LSB5-040Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page