T2 1830-0001SRecalls & reported problems
Stryker GmbH · Compression Screw, Advanced · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 04546540201133), received between Apr 26, 2019 and Oct 19, 2023 — classified as 1 injury, 1 malfunction.
The most frequently reported specific device problem is “Device Difficult to Setup or Prepare” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Device Difficult to Setup or Prepare1
- Device Dislodged or Dislocated1
Patient problems
- Limb Fracture1
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryOct 19, 2023Device Difficult to Setup or Prepare; Device Difficult to Setup or Prepare
AS REPORTED: "IN A RETROGRADE CASE, THE TIMING OF COMPRESSION SCREW INSERTION WAS INCORRECT. THE COMPRESSION SCREW WAS INSERTED TO THE FRONT OF THE DYNAMIC HOLE WITH THE NAIL HOLDING SCREW REMOVED FROM THE NAIL. BECAUSE THE DEVICE AND THE NAIL WERE NOT SECURED, THE NAIL MIGRATED DEEPLY, RESULTING IN A FRACTURE WITH A THIRD BONE FRAGMENT WHEN ATTEMPTING TO REATTACH THE DEVICE AND THE NAIL IN THE MEDULLARY CAVITY. THE NAIL DEPTH WAS THEN READJUSTED USING A UNIVERSAL ROD AND PROXIMAL SCREW FIXATION WAS PERFORMED. WHEN COMPRESSION WAS ATTEMPTED WITH THE COMPRESSION SCREW AFTER INSERTION OF THE DISTAL SCREW, THE COMPRESSION SCREW COULD NOT MOVE AND COMPRESSION COULD NOT BE PERFORMED, PROBABLY DUE TO CROSS-THREADING. IN ADDITION, BECAUSE THE COMPRESSION SCREW HAD BLOCKED THE SCREW HOLE, THE PLANNED SCREW COULD NOT BE INSERTED AND ONLY ONE DISTAL SCREW FIXATION WAS NEEDED. AS FOR THE END CAP, IT WAS ALSO IMPLANTED WITH ABOUT 2 MM PROTRUDING FROM THE NAIL END DUE TO POOR PLACEMENT OF THE COMPRESSION SCREW." ADDITIONALLY A 60 MINUTE SURGICAL DELAY WAS REPORTED.
Patient problems: Limb Fracture
MAUDE report 17969627 ↗MalfunctionApr 26, 2019Device Dislodged or Dislocated
THE SCREW WAS BACKING OUT OF THE NAIL. NAIL IS STILL IN THE PATIENT.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8556595 ↗
Other ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES devices
- NA 03.033.001Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES265 reports
- GAMMA 3125-1180SStryker GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES249 reports
- NA 03.037.026Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES225 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-075Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls2 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-045Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- PRECICE® Intramedullary Limb Lengthening System LSC5-050Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- TRIGEN 71674067Smith & Nephew, Inc. · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES201 reports
- PRECICE Intramedullary Limb Lengthening System LSB5-040Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page