T2 1830-0727SRecalls & reported problems
Stryker GmbH · Humeral Nail · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04546540201331), received between Apr 1, 2021 and Apr 1, 2021 — classified as 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Break1
- Fracture1
Patient problems
- Foreign Body In Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 1, 2021Break; Fracture; Break; Fracture
AS REPORTED: "PRIMARY PROCEDURE, LEFT HUMERAL NAIL. IT WAS REPORTED THAT AFTER THE LOCKING SCREW WAS IMPLANTED AT THE DISTAL END OF THE NAIL, THE SURGEON BACK-SLAPPED THE CONSTRUCT TO COMPRESS A FRACTURE. THE DISTAL END OF THE NAIL BROKE AT THE JUNCTION WITH THE LOCKING SCREW. THE SCREW WAS REMOVED AND ANOTHER LOCKING SCREW WAS IMPLANTED ABOVE THE PREVIOUS IMPLANT SITE. PROCEDURE WAS COMPLETED SUCCESSFULLY WITH A DELAY OF APPROXIMATELY 1-2 MINUTES. ADDITIONAL INFO RECEIVED ON 03/09/2021 DISTAL LOCKING SCREW DID NOT BREAK, ONLY DISTAL END OF NAIL. DISTAL LOCKING SCREW WAS REMOVED AND REPLACED WITH ANOTHER LOCKING SCREW THAT LOCKED THE NAIL IN THE MOST PROXIMAL HOLE OF THE DISTAL LOCKING OPTIONS IN. THE BROKEN TIP AS WELL AS THE REST OF THE NAIL AND LOCKING SCREWS REMAINS IN PATIENT TO FIX THEIR MID SHAFT HUMERUS FRACTURE. THE SMALL UNIVERSAL EXTRACTION ROD THAT IS DEDICATED TO THE T2 HUMERAL SYSTEM WAS USED TO BACK-SLAP. THE SCREW WAS NOT BROKEN, THE TIP OF THE NAIL AT THE SCREW HOLE JUNCTION WAS."
Patient problems: Foreign Body In Patient
MAUDE report 11604256 ↗
Other ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES devices
- NA 03.033.001Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES265 reports
- GAMMA 3125-1180SStryker GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES249 reports
- NA 03.037.026Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES225 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-075Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls2 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-045Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- PRECICE® Intramedullary Limb Lengthening System LSC5-050Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- TRIGEN 71674067Smith & Nephew, Inc. · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES201 reports
- PRECICE Intramedullary Limb Lengthening System LSB5-040Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page