The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 04546540371720), received between Mar 17, 2017 and Mar 28, 2024 — classified as 5 malfunctions.

The most frequently reported specific device problem is “Fracture” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 1 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fracture3
  • Break1
  • Detachment Of Device Component1
  • Device Dislodged or Dislocated1
  • Disassembly1
  • Material Separation1
  • Mechanical Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions3
  • Fall1
  • No Consequences Or Impact To Patient1
  • No Known Impact Or Consequence To Patient1

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 28, 2024Fracture; Fracture

    IT WAS REPORTED THAT AFTER A REVISION SURGERY FOR OASYS BLOCKER AND SCREW MIGRATION, IT WAS NOTICED THAT ONE OASYS POLYAXIAL SCREW HAD FRACTURED. RE-REVISION IS NOT SCHEDULED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18991044 ↗
  • MalfunctionJun 13, 2022Fracture; Fracture

    IT WAS REPORTED THAT DURING A REVISION SCOLIOSIS SURGERY THREE OASYS POLYAXIAL WERE DISCOVERED TO BE BROKEN APPROXIMATELY 9 YEARS POST-OPERATIVELY. THE BROKEN SCREWS WERE LEFT IN THE PATIENT'S VERTEBRA. THIS REPORT CAPTURES THE THIRD OF THE THREE SCREWS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14674738 ↗
  • MalfunctionJun 13, 2022Fracture; Fracture

    IT WAS REPORTED THAT DURING A REVISION SCOLIOSIS SURGERY THREE OASYS POLYAXIAL WERE DISCOVERED TO BE BROKEN APPROXIMATELY 9 YEARS POST-OPERATIVELY. THE BROKEN SCREWS WERE LEFT IN THE PATIENT'S VERTEBRA. THIS REPORT CAPTURES THE FIRST OF THE THREE SCREWS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 14674737 ↗
  • MalfunctionMay 20, 2020Material Separation; Device Dislodged or Dislocated; Material Separation; Device Dislodged or Dislocated

    IT WAS REPORTED THAT AN OASYS POLYAXIAL SCREW TULIP DISENGAGED INTRA-OPERATIVELY. THE SURGEON ATTEMPTED TO PULL OUT THE SCREW AT WITH A SCREWDRIVER, BUT IT WAS TOO HARD TO PULL OUT. SO, HE THEN USED A SHORT ROD AND TIGHTENED IT WITH A BLOCKER AND TRIED TO PULL IT OUT, BUT THE SCREW HEAD CAME OFF. THE SURGEON LEFT THE FRACTURED SHAFT IN THE PATIENT.

    Patient problems: Fall; No Consequences Or Impact To Patient

    MAUDE report 10075560 ↗
  • MalfunctionMar 17, 2017Break; Detachment Of Device Component; Disassembly; Mechanical Problem; Disassembly; Mechanical Problem

    IT WAS REPORTED THAT THE HEAD BROKE OFF THE TULIP SCREW DURING THE CASE. THE FURTHER REPORTED THAT THE CONSTRUCT HAD BEEN LOCKED DOWN WITH THE ROD AND THE BLOCKER. THE SURGEON THEN CHECKED ON X-RAY AND WANTED TO CHANGE THE DIRECTION OF THE TULIP HEAD. WHEN HE TRIED TO ADJUST IT THE HEAD BROKE OFF THE SCREW. THE TULIP HEAD WAS REMOVED WITH FORCEPS AND THE SURGEON WAS ABLE TO UNWIND THE THREAD FROM THE BONE. NO UNINTENDED METAL WAS LEFT IN THE PATIENT. THE BONE WAS GOOD QUALITY AND THERE WERE NO OTHER OBVIOUS ISSUES. A NEW SCREW WAS INSERTED AND THE CASE WAS COMPLETED SUCCESSFULLY WITH NO LASTING CONSEQUENCES FOR THE PATIENT. THERE WAS A 30 MINUTE DELAY TO SURGERY AS A RESULT OF THE REPORTED EVENT.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 6413754 ↗