GAMMA 3130-2170SRecalls & reported problems

Stryker GmbH · Trochanteric Nail Kit, Ti · Class 2 · Implant

All models of GAMMA (249)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
4
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 04546540375148), received between Nov 15, 2018 and Oct 25, 2023 — classified as 4 injuries.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem2
  • Appropriate Device Problem Term/Code Not Available1
  • Break1
  • Patient-Device Incompatibility1

Patient problems

  • Ambulation or Postural Difficulties1
  • Bone Fracture(s)1
  • No Known Impact Or Consequence To Patient1
  • Pain1
  • Perforation1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • InjuryOct 25, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    AS REPORTED: "AFTER SURGERY, THE U-LAG SCREW CUT OUT THE FEMORAL HEAD WITH U-BLADE DEFORMATION AND THE REVISION SURGERY WAS PERFORMED."

    Patient problems: Perforation

    MAUDE report 18001391 ↗
  • InjurySep 15, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT DURING INSERTION OF THE NAIL, A FRACTURE OCCURRED AT ANOTHER SITE. IT WAS DETERMINED THE SURGERY COULD BE CONTINUED AND THE PROCEDURE WAS COMPLETED AS PLANNED. NO TREATMENT WAS PERFORMED FOR THE SUBTROCHANTERIC FRACTURE.

    Patient problems: Bone Fracture(s)

    MAUDE report 12478236 ↗
  • InjuryMar 12, 2019Break; Appropriate Device Problem Term/Code Not Available

    IT WAS REPORTED THAT THE GAMMA NAIL (3130-2170S) WAS INSERTED ABOUT ONE YEAR BEFORE. THE DISTAL OF THE NAIL WAS BROKEN AND IT WAS REVISED TO GAMMA LONG NAIL AT (B)(6) 2019. AT REVISION SURGERY, IT WAS 130° NAIL TO DETAIN, BUT ONLY THE 125° NAIL WAS PREPARED. THE REASON OF THIS EVENT WAS MISCOMMUNICATION OF SURGEON AND SR. SURGERY STOPPED ABOUT 90 MIN WITH ANESTHESIA ON THE PATIENT TO WAIT FOR THE ARRIVAL OF THE IMPLANT. AFTER THAT, THE SURGERY WAS FINISHED WITH NO PROBLEM.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 8414661 ↗
  • InjuryNov 15, 2018Patient-Device Incompatibility

    CUT OUT OF U LAG SCREW OCCURS. PATIENT FELT PAIN ON HIS HIP FOR SEVERAL WEEKS AND DIFFICULT TO WALK. THEN, WHEN FALLING ON (B)(6), VISITED IN THE HOSPITAL AND AN X - RAY FILM WAS TAKEN, IT TURNED OUT THAT THE LAG SCREW HAD CUT OUT AND REACHED THE ACETABULAR. THERE IS NO DISLOCATION OF THE PIECES OF THE BONY SKULL, AND ONLY THE LAG SCREW HAS CUT OUT. AS A MEASURE AFTER OCCURRENCE, ON (B)(6) REPLACED 120 ° GAMMA NAIL.

    Patient problems: Ambulation or Postural Difficulties; Pain

    MAUDE report 8074995 ↗