Stryker GmbH · Long Nail Kit R1.5, Ti, LEFT · Class 2 · Implant

All models of GAMMA (249)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
7
Deaths reported
0
Injuries reported
7
Recalls naming it
0

Summary

The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 04546540375759), received between Apr 25, 2019 and Dec 10, 2025 — classified as 7 injuries.

The most frequently reported specific device problem is “Fracture” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 2 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fracture4
  • Break3
  • Adverse Event Without Identified Device or Use Problem2
  • Malposition of Device1

Patient problems

  • Failure of Implant4
  • Nonunion/Delayed-union Bone Fracture2
  • Hip Fracture1
  • Implant Pain1
  • Injury1
  • Insufficient Information1
  • Necrosis1

Recent adverse event reports

The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.

  • InjuryDec 10, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT THE PATIENT'S LEFT FEMUR WAS REVISED DUE TO NECROSIS OF THE PATIENT'S NATIVE FEMORAL HEAD. A GAMMA3 NAIL (WITH 1 LAG SCREW AND 1 DISTAL SCREW) WAS REMOVED AND THE PATIENT WAS CONVERTED TO A TOTAL HIP. REP CONFIRMED THAT NO FURTHER INFORMATION WILL BE RELEASED BY THE HOSPITAL OR SURGEON.

    Patient problems: Necrosis

    MAUDE report 23772272 ↗
  • InjuryDec 3, 2025Fracture; Fracture

    AS REPORTED: "NAIL FAILURE AT INTERSECTION NAIL-LAG SCREW. APPROX. 4 MONTHS AFTER IMPLANTATION. THE PATIENT WAS REOPERATED ON (B)(6) 2025."

    Patient problems: Insufficient Information

    MAUDE report 23707095 ↗
  • InjuryMar 17, 2025Break; Fracture; Break; Fracture

    IT WAS REPORTED BY THE PATIENT THAT THEY HAD A NAIL IMPLANTED, WHICH BROKE AND WAS REMOVED.

    Patient problems: Failure of Implant; Nonunion/Delayed-union Bone Fracture

    MAUDE report 21625918 ↗
  • InjuryJul 27, 2022Break; Fracture; Break; Fracture

    THE CUSTOMER REPORTED A BROKEN GAMMA3 NAIL (3525-0360S). "THE PATIENT WAS TREATED EXTERNALLY FOR A PER/SUBTROCHANTERIC LEFT FEMUR FRACTURE ON (B)(6) 2021 WITH A GAMMA NAIL. DURING THE CONSULTATION (B)(6) 2022, THE IMPLANT FRACTURE WAS DIAGNOSED AND THE PATIENT WAS ADMITTED TO HIP CLINIC AT BALGRIST UNIVERSITY HOSPITAL FOR FURTHER TREATMENT. HERE THE INDICATION FOR REVISION WAS GIVEN IN CASE OF SYMPTOMATIC PSEUDARTHROSIS. IF THE BONE FAILED TO HEAL AND THE IMPLANT FRACTURED, THE INDICATION FOR REVISION WAS GIVEN. THE INDICATION FOR REVISION WAS GIVEN AND THE PATIENT HAD TO UNDERGO SURGERY ON (B)(6) 2022."

    Patient problems: Failure of Implant; Nonunion/Delayed-union Bone Fracture

    MAUDE report 15112656 ↗
  • InjuryNov 24, 2021Break; Fracture; Break; Fracture

    AS REPORTED: "FRACTURE OF GAMMA NAIL AT THE FEMORAL NECK SCREW (LEFT THIGH) PAIN SINCE END OF (B)(6) 2021. THE PATIENT REQUIRED A REVISION SURGERY."

    Patient problems: Failure of Implant; Implant Pain

    MAUDE report 12867650 ↗
  • InjuryMar 4, 2021Malposition of Device; Malposition of Device

    AS REPORTED: "MEDIAL MIGRATION OF GAMMA LAG SCREW INTO PATIENT¿S PELVIS. REVISION THA SCHEDULED THE (B)(6) 2021 TO REMOVE LAG SCREW AND REPLACE HIP."

    Patient problems: Failure of Implant; Hip Fracture

    MAUDE report 11411534 ↗
  • InjuryApr 25, 2019Adverse Event Without Identified Device or Use Problem

    IT'S ALLEGED BY THE ATTORNEY, THROUGH THE FILING OF A LAWSUIT, THAT THE PLAINTIFF WAS INJURED BY A STRYKER GAMMA NAIL ON (B)(6) 2018.

    Patient problems: Injury

    MAUDE report 8553342 ↗