Dall-Miles 6704-3-081Recalls & reported problems
Howmedica Osteonics Corp. · Trochanteric grip plate with 2 cables · Class 2 · Implant
All models of Dall-Miles (12)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04546540568106), received between Jul 12, 2018 and Jul 12, 2018 — classified as 1 injury.
The most frequently reported specific device problem is “Migration” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Migration1
Patient problems
- Bone Fracture(s)1
- Injury1
- Joint Dislocation1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryJul 12, 2018Migration; Migration
AS REPORTED: "CHRONIC DISLOCATIONS, CONSTRAINED LINER DAMAGE DURING DISLOCATION. [DALL MILES] PLATE REMOVED"; LEFT HIP. UPDATE 14 JUNE, 2018: THE MEDICAL REVIEW HAS CONFIRMED THAT THE CONSTRAINED LINER HAS DISASSOCIATED FROM AN UNKNOWN TRIDENT SHELL. IT HAS ALSO CONFIRMED LOOSENING OF THE DALL MILES PLATE. THE CONCLUSION OF THE ASSESSMENT IS AS FOLLOWS: "NON-UNION OF A GREATER TROCHANTERIC FRACTURE, PRESENT ALREADY BEFORE IMPLANTATION OF THE PREDICATE DEVICES AFTER A PERIPROSTHETIC FRACTURE DUE TO A FALL OF THE PATIENT IN 2015, DESPITE ADEQUATE TREATMENT, HAS CONTRIBUTED TO AN OVERLOAD CONDITION ON THE IMPLANTED CONSTRAINED LINER FORCING A COMPLETE PULL-OUT OF THE CONSTRAINED LINER FROM THE CUP SHELL REQUIRING A THIRD REVISION IN (B)(6) 2018". UPDATE 18 JUNE 18: A REVIEW BY A CLINICAL CONSULTANT HAS CONFIRMED A FRACTURED DALL MILES CABLE.
Patient problems: Bone Fracture(s); Injury; Joint Dislocation
MAUDE report 7681399 ↗
Other CERCLAGE, FIXATION devices
- ZipFix 03.501.080Synthes GmbH · CERCLAGE, FIXATION236 reports
- CONTROL 1739-28-000Depuy Orthopaedics, Inc. · CERCLAGE, FIXATION52 reports
- Dall-Miles 6704-0-110Howmedica Osteonics Corp. · CERCLAGE, FIXATION1 recall1 report
- Tritium® Sternal Cable Plate System 86-27-12-S12Pioneer Surgical Technology, Inc. · CERCLAGE, FIXATION1 recall0 reports
- Accord 71340007Smith & Nephew, Inc. · CERCLAGE, FIXATION47 reports
- ZipFix 08.501.001.01SSynthes GmbH · CERCLAGE, FIXATION39 reports
- NA 298.801.01SSynthes GmbH · CERCLAGE, FIXATION33 reports
- ZipFix 08.501.001.05SSynthes GmbH · CERCLAGE, FIXATION29 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page