NA 55-08216Recalls & reported problems
Stryker Leibinger GmbH & Co. KG · BONE PLATE, MP, STRAIGHT · Class 2 · Implant
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04546540602718), received between Mar 25, 2020 and Mar 25, 2020 — classified as 1 injury.
The most frequently reported specific device problem is “Device Appears to Trigger Rejection” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
- Device Appears to Trigger Rejection1
Patient problems
- Abscess1
- Bacterial Infection1
- Pain1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryMar 25, 2020Device Appears to Trigger Rejection; Adverse Event Without Identified Device or Use Problem; Device Appears to Trigger Rejection; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED BY A SURGEON THAT A PATIENT REQUIRED A REVISION SURGERY DUE TO EXPERIENCING PAIN AND HAVING PUS SECRETIONS APPROXIMATELY 4-5 WEEKS AFTER INITIAL IMPLANTATION WITH AN IMPLANT. THE ORIGINAL PROCEDURE WAS REPORTED AS COMPLETED SUCCESSFULLY WITHOUT A DELAY, BUT DURING THE REVISION SURGERY IT WAS FOUND THAT THE SCREWS HAD LOOSENED, CALCIFICATION FORMED NEAR THE PLATE, AND A PATIENT SWAB TESTED AS MRSA POSITIVE. THE PLATE WAS REMOVED.
Patient problems: Abscess; Bacterial Infection; Pain
MAUDE report 9876841 ↗
Other PLATE, BONE devices
- MatrixNEURO 04.503.104.01Synthes GmbH · PLATE, BONE252 reports
- RapidSorb 806.004.02SSynthes GmbH · PLATE, BONE146 reports
- TruMatch SD980.001Materialise NV · Plate, Bone1 recall21 reports
- Matrix 04.511.225.01Synthes GmbH · PLATE, BONE62 reports
- NA 400.834Synthes GmbH · PLATE, BONE58 reports
- TruMatch SD980.016Materialise NV · Plate, Bone55 reports
- ProPlan CMF SD900.101Materialise NV · Plate, Bone1 recall1 report
- TruMatch SD980.013Materialise NV · Plate, Bone1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page