MANTIS Redux 48289735Recalls & reported problems
Stryker Corporation · POLYAXIAL REDUCTION SCREW · Class 2 · Implant
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04546540671240), received between Jul 14, 2016 and Jul 14, 2016 — classified as 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Break1
- Positioning Problem1
Patient problems
- No Code Available1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 14, 2016Break; Positioning Problem
IT WAS REPORTED THAT; SALES REP : AFTER THE SETTING UP 4 SCREWS, THE SURGEON SET UP THE CURVED STEM LENGTH 50 MM AND INSERTED THE NUT WITH NUT DRIVER. DURING THE FINAL TIGHTENING WITH A TORQUE WRENCH AND ANTI-TORQUE WRENCH ON THE LEFT L5 LEVEL, THE NUT DID NOT HOLD INTO THE SCREW HEAD. THE SURGEON REMOVED THE NUT AND OBSERVED THAT THE THREADS OF THE SCREW HEAD (TULIP) WERE DAMAGED. THE SURGEON REMOVED THE NUT ON THE LEFT S1 LEVEL, REMOVED THE LEFT UPPER SIDE AND THE LEFT L5 SCREW. THE SURGEON CHANGED THE LEFT L5 SCREW BY INSERTING A NEW SCREW DIA. 7.5 X 40MM REF. , THEN PLACED ANOTHER ROD, THEN 2 NUTS, AND FINAL TIGHTENING WITH A TORQUE WRENCH. DELAY OF 15-20 MINUTES, TIME TO DISASSEMBLE THE LEFT SIDE ASSEMBLY, REPOSITIONING THE SCREW AND REPLACE THE ROD AND LEFT FINAL TIGHTENING."
Patient problems: No Code Available
MAUDE report 5796882 ↗
Other Orthosis, spinal pedicle fixation, for degenerative disc disease devices
- EXPEDIUM VERSE 199721000Medos International Sàrl · Orthosis, spinal pedicle fixation, for degenerative disc disease387 reports
- Sequoia® 3301-1Zimmer Spine, Inc. · Orthosis, spinal pedicle fixation, for degenerative disc disease184 reports
- CD HORIZON® Spinal System 8590855Medtronic Sofamor Danek, Inc. · Orthosis, spinal pedicle fixation, for degenerative disc disease179 reports
- Vitality® 07.02011.001Biomet Spine LLC · Orthosis, spinal pedicle fixation, for degenerative disc disease3 recalls0 reports
- EXPEDIUM VERSE 199721001SMedos International Sàrl · Thoracolumbosacral pedicle screw system124 reports
- LineSider LS-N6SA7550Integrity Implants Inc. · Thoracolumbosacral Pedicle Screw System2 recalls1 report
- LineSider LS-N6SA6545Integrity Implants Inc. · Thoracolumbosacral Pedicle Screw System2 recalls0 reports
- EXPEDIUM VERSE 199721000SMedos International Sàrl · Thoracolumbosacral pedicle screw system97 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.