T2 1818-1220SRecalls & reported problems
Stryker GmbH · Ankle Arthrodesis Nail, left · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04546540673350), received between Feb 21, 2025 and Feb 21, 2025 — classified as 1 malfunction.
The most frequently reported specific device problem is “Difficult to Insert” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Difficult to Insert1
Patient problems
- Insufficient Information1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 21, 2025Difficult to Insert; Difficult to Insert
AS REPORTED: "THE END USER HAS REPORTED THAT AN ISSUE HAS OCCURRED DURING THE T2 ANKLE FUSION SURGERY PERFORMED. AFTER SUCCESSFULLY PLACING THE DYNAMIC COMPRESSION SCREWS AND PROXIMAL STATIC SCREWS, THEY ENCOUNTERED A PROBLEM WHILE ATTEMPTING TO PLACE THE POSTERIOR CALCANEUS SCREWS. THE DRILL WAS UNABLE TO PASS THROUGH THE NAIL AND INSTEAD HIT THE NAIL, NOT GOING THROUGH THE DEDICATED HOLE AS INTENDED. THE SURGEON WAS UNABLE TO GENERATE PROPER COMPRESSION TO ENHANCE THE FUSION PROCEDURE, WHICH SIGNIFICANTLY IMPACTED THE OUTCOME OF THE SURGERY. DUE TO THE DEFECT, THE SURGEON HAD TO FREEHANDEDLY INSERT THE SCREW, WHICH CAUSED A SIGNIFICANT DELAY AND INCONVENIENCE, AFFECTING THE OVERALL OPERATING TIME".
Patient problems: Insufficient Information
MAUDE report 21437927 ↗
Other ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES devices
- NA 03.033.001Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES265 reports
- GAMMA 3125-1180SStryker GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES249 reports
- NA 03.037.026Synthes GmbH · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES225 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-075Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls2 reports
- PRECICE® Intramedullary Limb Lengthening System LSC5-045Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- PRECICE® Intramedullary Limb Lengthening System LSC5-050Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls1 report
- TRIGEN 71674067Smith & Nephew, Inc. · ROD, FIXATION, INTRAMEDULLARY AND ACCESSORIES201 reports
- PRECICE Intramedullary Limb Lengthening System LSB5-040Nuvasive Specialized Orthopedics, Inc. · Rod, Fixation, Intramedullary And Accessories4 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page