TARGET M0035424060Recalls & reported problems
Stryker Corporation · 360 Ultra Detachable Coil · Class 2 · Implant
All models of TARGET (114)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 6
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 04546540675910), received between Jul 20, 2017 and Nov 4, 2025 — classified as 2 injuries, 4 malfunctions.
The most frequently reported specific device problem is “Fracture” (3 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Fracture3
- Premature Separation2
- Device Dislodged or Dislocated1
- Expulsion1
- Premature Activation1
Patient problems
- No Clinical Signs, Symptoms or Conditions4
- No Known Impact Or Consequence To Patient1
- Vasoconstriction1
Recent adverse event reports
The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.
MalfunctionNov 4, 2025Fracture; Fracture
THE COIL (SUBJECT DEVICE) WAS USED IN THE MEDICAL PROCEDURE. HOWEVER, WHEN THE COIL WAS PLACED IN THE ANEURSYM DURING DETACHMENT A SMALL PORTION OF THE TAIL END OF THE COIL DELIVERY WIRE BROKE OFF IN THE DETACHMENT DEVICE AND THE COIL COULD NOT BE DETACHED. THE SUBJECT DEVICE WAS REPLACED, AND THE PROCEDURE WAS COMPLETED SUCCESSFULLY. NO CLINICAL CONSEQUENCES WERE REPORTED TO THE PATIENT DUE TO THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 23468485 ↗MalfunctionJul 24, 2025Fracture; Premature Separation; Fracture; Premature Separation
IT WAS REPORTED DURING THE PROCEDURE THE SUBJECT COIL HAD TO BE REPOSITIONED FOR PLACEMENT. WHEN THE COIL WAS RETRIEVED BACK INTO THE CATHETER, IT DETACHED AND WAS FRACTURED INTO TWO PARTS. ONE FRAGMENT WAS REMOVED FROM THE CATHETER AND ONE FRAGMENT REMAINED IN THE CATHETER. THE DEVICE WAS REPLACED, AND THE PROCEDURE WAS COMPLETED SUCCESSFULLY. NO CLINICAL CONSEQUENCES WERE REPORTED TO THE PATIENT DUE TO THIS EVENT. THE SUBJECT COIL WAS RETURNED FOR ANALYSIS AND WAS EXAMINED, AND IT WAS DISCOVERED THAT THE REPORTED EVENT OF THE SUBJECT MAIN COIL WAS DETACHED AT THE DISTAL END OF MICROCATHETER SHAFT AND WAS BROKEN INTO TWO PARTS DURING USE WAS NOT CONFIRMED. THE SUBJECT COIL DELIVERY WIRE WAS FOUND TO BE KINKED, THE MAIN COIL WAS FOUND TO BE STRETCHED, AND THE SUTURE OF SUBJECT MAIN COIL WAS FOUND TO BE DAMAGED. NO CLINICAL CONSEQUENCES WERE REPORTED TO THE PATIENT DUE TO THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22586491 ↗MalfunctionMar 12, 2025Device Dislodged or Dislocated; Device Dislodged or Dislocated
IT WAS REPORTED THAT WHEN INSERTING THE SUBJECT COIL INTO THE RHV (ROTATING HEMOSTASIS VALVE) OF THE MICROCATHETER DURING AN ANEURYSM COIL EMBOLIZATION PROCEDURE, THE FLUORO-SAVER MARKERS WERE VISIBLE ON THE COIL DELIVERY WIRE. HOWEVER, THE SUBJECT COIL HAD ALREADY REACHED THE ANEURYSM WHEN THE FLUOROSCOPY WAS TURNED TO VISUALIZE THE COIL POSITION. THE SUBJECT COIL WAS IMPLANTED WITHOUT ANY ISSUES, THE PROCEDURE WAS COMPLETED SUCCESSFULLY AND THERE WERE NO CLINICAL CONSEQUENCES TO THE PATIENT DUE TO THE REPORTED EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21590255 ↗InjurySep 28, 2022Expulsion; Premature Separation; Expulsion; Premature Separation
IT WAS REPORTED THAT DURING THE PROCEDURE THE COIL (SUBJECT DEVICE) WAS ACCIDENTALLY DEPLOYED PARTIALLY OUTSIDE OF AN ACOM ( ANTERIOR COMMUNICATING ARTERY) ANEURYSM AND WAS SUSPENDED IN THE PARENT ACA (ANTERIOR CEREBRAL ARTERY) VESSEL. THE PHYSICIAN SUCCESSFULLY RETRIEVED THE COIL USING A RETRIEVER AND CATHETER (UNDER ASPIRATION). THE PATIENT DEVELOPED VASOSPASM IN THE RIGHT MCA (MIDDLE CEREBRAL ARTERY) WHICH CLEARED AFTER 10 MINUTES OF THE PHYSICIAN ADMINISTERING VERAPAMIL. THE PHYSICIAN SUCCESSFULLY COMPLETED THE PROCEDURE BY PLACING FIVE COILS IN THE ANEURYSM AND THE PATIENT WAS STABLE POST PROCEDURE.
Patient problems: Vasoconstriction
MAUDE report 15500202 ↗MalfunctionMar 17, 2021Fracture; Fracture
ANALYSIS OF THE RETURNED DEVICE FOUND THAT THE DELIVERY WIRE WAS BROKEN DURING USE. THERE WAS NO CLINICAL CONSEQUENCE TO THE PATIENT AS A RESULT OF THIS EVENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11509810 ↗InjuryJul 20, 2017Premature Activation; Premature Activation
DURING A COIL EMBOLIZATION PROCEDURE, DETACHMENT OF THE COIL WAS PERFORMED; HOWEVER, THE COIL DID NOT DETACH. IT WAS REPORTED THAT DURING WITHDRAWAL OF THE COIL, IT DETACHED, AND A SNARE DEVICE WAS USED TO REMOVE THE COIL. THE PROCEDURE WAS CONTINUED WITH ANOTHER COIL WITHOUT CLINICAL CONSEQUENCES TO THE PATIENT.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6730367 ↗
Other Device, Vascular, for Promoting Embolization devices
- POD RBYPOD8-APenumbra, Inc. · Device, Vascular, For Promoting Embolization195 reports
- CEREPAKTM MDH1Cerenovus, Inc. · Device, Vascular, for Promoting Embolization1 recall72 reports
- Azur CX Detachable 45-750824Microvention, Inc. · Device, Vascular, for Promoting Embolization115 reports
- Tornado G08261Cook Incorporated · Device, Vascular, for Promoting Embolization2 recalls7 reports
- Optima Coil System OPTI0930CSFMXBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls4 reports
- Optima Coil System OPTI0720CSFMXBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls4 reports
- Optima Coil System OPTI0413CSFMXBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls3 reports
- Prestige Coil System PRES0520HPKPLBalt USA LLC · Device, Vascular, For Promoting Embolization2 recalls3 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.