FUJIFILM EB-530TRecalls & reported problems

Fujifilm Corporation · The device is intended for the observation, diagnosis, and endoscopic treatment of trachea and bronchial tree. · Class 2

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 04547410330151), received between Jan 11, 2018 and Jan 2, 2024 — classified as 1 injury, 2 malfunctions.

The most frequently reported specific device problem is “Contamination /Decontamination Problem” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 1 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Contamination /Decontamination Problem2
  • Microbial Contamination of Device2
  • Break1
  • Fracture1

Patient problems

  • No Consequences Or Impact To Patient2
  • No Known Impact Or Consequence To Patient2
  • Airway Obstruction1
  • Hemorrhage/Blood Loss/Bleeding1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjuryJan 2, 2024Break; Fracture; Break; Fracture

    ON (B)(6) 2023, FUJIFILM HEALTHCARE AMERICAS CORPORATION WAS INFORMED OF AN EVENT INVOLVING EB-530T. IT WAS REPORTED THAT THE LENS IS BROKEN. IN ADDITION, AIRWAY ENDO TRACHEAL TUBE BECAME CLOGGED WITH BLOOD. ENDOTRACHEAL TUBE CHANGED WITH A 7.5 SIZE. PROVIDER FORCED SCOPE IN A TUBE THAT WAS TOO SMALL.

    Patient problems: Airway Obstruction; Hemorrhage/Blood Loss/Bleeding

    MAUDE report 18431995 ↗
  • MalfunctionJan 11, 2018Microbial Contamination of Device; Contamination /Decontamination Problem; Microbial Contamination of Device; Contamination /Decontamination Problem

    FUJIFILM MEDICAL SYSTEMS U.S.A., INC. (FMSU) WAS INFORMED ON OCTOBER 25, 2017 BY A SERVICE PARTNER THAT A HOSPITAL HAD EXPERIENCED SEVERAL PSEUDOMONAS INFECTIONS IN THEIR RESPIRATORY DEPARTMENT AND THE DOCTORS WERE CONCERNED THEY COULD BE FROM ENDOSCOPES, ALTHOUGH THE SOURCE OF THE INFECTION HAD NOT BEEN DETERMINED. FUJIFILM ATTEMPTED TO CONTACT THE HOSPITAL AT THAT TIME, BUT THE HOSPITAL DID NOT RESPOND TO THE INQUIRY. ON (B)(6) 2017, FMSU WAS INFORMED BY SERVICE PARTNER THAT THERE WAS A SECOND INCIDENT OF A CERTAIN FUJIFILM BRONCHOSCOPE BEING USED RESULTING IN POSITIVE PATIENT BAL SAMPLE. ON JANUARY 5, 2018 FMSU WAS INFORMED BY THE HOSPITAL THAT ENDOSCOPE EB530T 1B084G148 WAS NOT INVOLVED IN THE SECOND INCIDENT REPORTED ON (B)(6) 2017 BUT WAS THE SUBJECT SCOPE REPORTED ON (B)(6) 2017. ENDOSCOPE EB530T 1B084G148 WAS USED ON (B)(6) 2017 TO OBTAIN PATIENT BAL SAMPLES WHICH RESULTED IN POSITIVE PSEUDOMONAS CULTURES. IN ADDITION, THE SCOPE EB530T 1B084G148 WAS NOTED TO HAVE EXCESSIVE AMOUNT OF FLUID COMING FROM SUCTION CHANNEL WHEN PROCESSING THE ENDOSCOPE, THEREFORE IT WAS REMOVED FROM SERVICE ON OR AROUND (B)(6) AND WAS THEN SENT TO A FUJIFILM AUTHORIZED SERVICE FACILITY FOR INSPECT

    Patient problems: No Consequences Or Impact To Patient; No Known Impact Or Consequence To Patient

    MAUDE report 7184539 ↗
  • MalfunctionJan 11, 2018Microbial Contamination of Device; Contamination /Decontamination Problem; Microbial Contamination of Device; Contamination /Decontamination Problem

    FUJIFILM MEDICAL SYSTEMS U.S.A., INC. (FMSU) WAS INFORMED ON OCTOBER 25, 2017 BY A SERVICE PARTNER THAT A HOSPITAL HAD EXPERIENCED SEVERAL PSEUDOMONAS INFECTIONS IN THEIR RESPIRATORY DEPARTMENT AND THE DOCTORS WERE CONCERNED THEY COULD BE FROM ENDOSCOPES, ALTHOUGH THE SOURCE OF THE INFECTION HAD NOT BEEN DETERMINED. FUJIFILM ATTEMPTED TO CONTACT THE HOSPITAL AT THAT TIME, BUT THE HOSPITAL DID NOT RESPOND TO THE INQUIRY. ON DECEMBER 12, 2017, FMSU WAS INFORMED BY A SERVICE PARTNER THAT THE HOSPITAL HAD USED THE ENDOSCOPE (EB530T SERIAL (B)(4)) TO OBTAIN PATIENT BAL SAMPLES WHICH RESULTED IN POSITIVE PSEUDOMONAS CULTURES. THE FIRST INSTANCE OF THE SUBJECT ENDOSCOPE SCOPE BAL SAMPLE RESULTING POSITIVE OCCURRED ON (B)(6) 2017. DURING THE (B)(6) EPISODE THE ENDOSCOPE WAS SUBSEQUENTLY TESTED FOR CONTAMINANTS AND RESULTED POSITIVE FOR PSEUDOMONAS. THE SUBJECT ENDOSCOPE WAS THEN SENT TO A FUJIFILM AUTHORIZED SERVICE FACILITY FOR INSPECTION AND REPAIR. THE SERVICE FACILITY COMPLETED THE REPAIR AND RETURNED THE SCOPE TO THE HOSPITAL ON NOVEMBER 29, 2017. THE ENDOSCOPE WAS REPROCESSED AND ON (B)(6) 2017, WAS USED AND RESULTED IN POSITIVE PATIENT BAL SAMPLES FOR PSEUDOMONAS. ALTHOUGH POSITIVE

    Patient problems: No Consequences Or Impact To Patient; No Known Impact Or Consequence To Patient

    MAUDE report 7182043 ↗