WatchTower ROAM SYS-NAVI02Recalls & reported problems

Intai Technology Corp. · Spine Surgery Navigation System · Class 2

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04719894320984), received between Mar 20, 2026 and Mar 20, 2026 — classified as 1 malfunction.

The most frequently reported specific device problem is “Failure to Align” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Failure to Align1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 20, 2026Failure to Align

    ON (B)(6) 2025, A FIELD FEEDBACK REPORT (FFR) WAS RECEIVED FROM COMPANY REPRESENTATIVE (B)(6) OF (B)(4). DURING THE CASE, THE SURGEON INITIATED SCREW PLACEMENT AT L5 USING FLUOROSCOPY DUE TO NAVIGATION SYSTEM REGISTRATION DELAYS. NAVIGATION WAS THEN STARTED AT L5 ON THE RIGHT, RESULTING IN ACCURATE SCREW PLACEMENT. HOWEVER, WHEN PROCEEDING TO THE RIGHT L3, THE REGISTRATION WAS NOTED TO BE INACCURATE. WHILE THE SYSTEM DISPLAYED THE T-AWL LOCATION AS CORRECT, A CONFIRMATION X-RAY REVEALED THE AWL TO BE APPROXIMATELY 1 CM INFERIOR TO THE WATCHTOWER DISPLAY. THE AXIAL TRAJECTORY APPEARED ACCURATE, AND THE SURGEON COMPENSATED BY REPOSITIONING THE AWL SUPERIORLY UNTIL ALIGNMENT WAS CONFIRMED RADIOGRAPHICALLY. THE WATCHTOWER IMAGE THEN SHOWED THE AWL TO BE 1 CM SUPERIOR TO THE PEDICLE. FOLLOWING THIS DISCREPANCY, THE SURGEON DISCONTINUED NAVIGATION AND COMPLETED THE PROCEDURE USING STANDARD X-RAY GUIDANCE. NO PATIENT HARM WAS REPORTED ON THIS EVENT, BUT AS THE ROOT CAUSE OF THE INACCURATE INSTRUMENT PLACEMENT COULD NOT BE CONCLUSIVELY DETERMINED AT THE TIME OF THE PROCEDURE, IT WAS DECIDED TO REPORT THIS CASE. ALL SCREWS WERE ULTIMATELY POSITIONED CORRECTLY USING FLUOROSCOPY WITHOUT ANY A

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24649308 ↗