Nihon Kohden SVM-7200 Series Vital Signs Monitor SVM-7260Recalls & reported problems
Nihon Kohden Corporation · Vital Signs Monitor with Nihon Kohden SpO2 technology of SVM-7200 Series Vital Signs Monitor · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 7
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 04931921005903), received between Oct 4, 2024 and Sep 30, 2026 — classified as 7 malfunctions.
The most frequently reported specific device problem is “Incorrect, Inadequate or Imprecise Result or Readings” (7 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Incorrect, Inadequate or Imprecise Result or Readings7
- Output Problem6
- Incorrect Measurement1
Patient problems
- No Clinical Signs, Symptoms or Conditions7
Recent adverse event reports
The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 30, 2026Incorrect, Inadequate or Imprecise Result or Readings; Output Problem
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50948180 ↗MalfunctionAug 7, 2026Incorrect, Inadequate or Imprecise Result or Readings; Output Problem
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 50176254 ↗MalfunctionAug 5, 2025Incorrect, Inadequate or Imprecise Result or Readings; Output Problem; Incorrect, Inadequate or Imprecise Result or Readings; Output Problem
THE CUSTOMER REPORTED THAT THE NIBP READINGS WERE INCONSISTENTLY NOT IN SPECIFICATIONS. THE NURSE JUST COULD NOT GET ACCURATE READINGS AND AT TIME NO READINGS. SOMETIMES MONITOR WOULD JUST KEEP PUMPING, SO THEY WOULD SHUT IT OFF AND USE ANOTHER MONITOR. THE BIOMEDICAL ENGINEER (BME) BROUGHT IT TO THE SHOP AND CONNECTED TO ONE OF THEIR PRONK SIMULATOR CUBES. THIS TEST DEVICE WILL RUN BLOOD PRESSURE, ECG, AND SPO2 SIMULATED FUNCTIONS. WHEN RUNNING BP SIMULATIONS A NORMAL READING OF 120/80, THE SPECIFICATIONS'S ARE + OR - 3. THIS MONITOR WOULD ONLY GET ONE OR TWO READINGS IN SPECIFICATION. THEN THE NEXT FEW WOULD-BE WAY OUT OF SPECIFICATION RANGE. THEY COULD NOT GET ENOUGH OF THEM WITHIN SPECIFICATION READINGS CONSISTENTLY. ALSO, THE PUMP MAKES ERRATIC, STRANGE OR UNUSUAL SOUNDS. NOT IN PATIENT USE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22722730 ↗MalfunctionJul 7, 2025Incorrect, Inadequate or Imprecise Result or Readings; Output Problem; Incorrect, Inadequate or Imprecise Result or Readings; Output Problem
THE CUSTOMER REPORTED THAT THE VITAL SIGN MONITORS WERE NOT PROPERLY TAKING NIBP READINGS, AND THE PUMP SOUNDED LIKE IT WAS GIVING OUT. THEY MENTIONED THAT THE READINGS WERE IN THE 200/90+ RANGE. THERE WAS NO PATIENT HARM REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22414184 ↗MalfunctionJul 7, 2025Incorrect, Inadequate or Imprecise Result or Readings; Output Problem; Incorrect, Inadequate or Imprecise Result or Readings; Output Problem
THE CUSTOMER REPORTED THAT THE VITAL SIGN MONITORS WERE NOT PROPERLY TAKING NIBP READINGS, AND THE PUMP SOUNDED LIKE IT WAS GIVING OUT. THEY MENTIONED THAT THE READINGS WERE IN THE 200/90+ RANGE. THERE WAS NO PATIENT HARM REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22413747 ↗MalfunctionJul 2, 2025Incorrect, Inadequate or Imprecise Result or Readings; Output Problem; Incorrect, Inadequate or Imprecise Result or Readings; Output Problem
THE CUSTOMER REPORTED THAT THE VITAL SIGN MONITORS WERE NOT PROPERLY TAKING NIBP READINGS, AND THE PUMP SOUNDED LIKE IT WAS GIVING OUT. THEY MENTIONED THAT THE READINGS WERE IN THE 200/90+ RANGE. THERE WAS NO PATIENT HARM REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 22387152 ↗MalfunctionOct 4, 2024Incorrect Measurement; Incorrect, Inadequate or Imprecise Result or Readings; Incorrect Measurement; Incorrect, Inadequate or Imprecise Result or Readings
THE CUSTOMER REPORTED THE VITAL SIGNS MONITOR (SVM) HAD INCORRECT NON-INVASIVE BLOOD PRESSURE (NIBP) READINGS WHILE IN PATIENT USE. NO PATIENT HARM WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20367150 ↗
Other Oximeter devices
- Trilogy Trilogy100 Ventilator, InternationalRespironics, Inc. · Oximeter8 deaths2,493 reports
- Trilogy Trilogy 202 Ventilator, United StatesRespironics, Inc. · Oximeter2 deaths1,594 reports
- HAMILTON-G5 159001Hamilton Medical AG · Oximeter18 deaths1,440 reports
- Trilogy Trilogy100 Ventilator, GermanyRespironics, Inc. · Oximeter696 reports
- Model EMV+ Vent, Army, MRI 799-EMVP-04Zoll Medical Corporation · Oximeter1 death605 reports
- Trilogy Evo, O2, Japan JP2100X16BRespironics, Inc. · Oximeter4 recalls5 deaths342 reports
- Model EMV+ Vent, Army, COMMERCIAL 799-EMVP-01-01Zoll Medical Corporation · Oximeter1 death497 reports
- HAMILTON-G5 159002Hamilton Medical AG · Oximeter3 deaths451 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page