Tissue-Tek VIP® 6 6040Recalls & reported problems
Sakura Finetek U.S.A., Inc. · AI · Class 1
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 04946433600539), received between May 29, 2025 and Jun 11, 2025 — classified as 2 injuries.
The most frequently reported specific device problem is “Insufficient Device Problem Information” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Insufficient Device Problem Information2
- Use of Device Problem1
Patient problems
- Insufficient Information2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryJun 11, 2025Use of Device Problem; Insufficient Device Problem Information; Use of Device Problem; Insufficient Device Problem Information
ON APRIL 7, 2025, (B)(6) NOTIFIED SAKURA FINETEK USA TECHNICAL SERVICES (TS) OF AN INCIDENT THAT OCCURRED ON (B)(6) 2025, INVOLVING THE TISSUE-TEK VIP 6 AI VACUUM INFILTRATION PROCESSOR (115 VAC, 50/60 HZ, 12 A). ON THE DAY OF THE INCIDENT, THE UNIT PROCESSED 140 TISSUE SAMPLES- A MIX OF FATTY AND LARGE AUTOPSY TISSUES- WHICH APPEARED TO BE EITHER OVER-PROCESSED OR UNDER-PROCESSED. (B)(6) REPORTED THAT, IN SOME CASES, THE NUCLEI WERE COMPLETELY OBLITERATED, GIVING THE TISSUE THE APPEARANCE OF AUTOLYZED OR "COOKED" AUTOPSY TISSUE. ALL CASSETTES FROM THAT PROCESSING RUN WERE AFFECTED TO VARYING DEGREES, THOUGH ONLY FOUR CASES WERE DEEMED UNDIAGNOSABLE: THREE BREAST TISSUE CASES AND ONE COLON CASE WITH LYMPH NODES. ACCORDING TO (B)(6), THESE FOUR CASES WERE SIGNED OUT AS UNDIAGNOSABLE DUE TO PROCESSING ERRORS AND ARTIFACTS THAT RENDERED THE TISSUE SLIDES UNREADABLE. SAKURA FINETEK USA RECEIVED FURTHER DETAILS REGARDING THE INDIVIDUAL CASES AT A LATER DATE DUE TO HIPAA RESTRICTIONS. THE REPORTED CASES WERE SUMMARIZED AS FOLLOWS: CASE 1: COLON CANCER- STAGING COULD NOT BE DETERMINED. CASE 2: MASTECTOMY WITH A PRIOR DIAGNOSIS OF DCIS- UNABLE TO CONFIRM THE PRESENCE OF INVASIVE CANCER. CA
Patient problems: Insufficient Information
MAUDE report 22187929 ↗InjuryMay 29, 2025Insufficient Device Problem Information; Insufficient Device Problem Information
SAKURA FINETEK USA WAS NOTIFIED BY FDA ON 30-APR-2025 ABOUT THE MEDICAL DEVICE REPORT SUBMITTED VIA MEDWATCH PROGRAM. THE EMAIL NOTIFICATION FROM FDA INCLUDED NOTIFICATION LETTER AND THE SUBMITTED MEDICAL DEVICE REPORT FOR SAKURA FINETEK USA'S AWARENESS. THE MEDICAL DEVICE REPORT (FORM 3500A) WAS SUBMITTED BY AN ANONYMOUS CUSTOMER FOR THE EVENT THAT TOOK PLACE IN 19-MAR-2025. IN THE REPORT SUBMITTED TO THE FDA, CUSTOMER HAS DESCRIBED THAT A TISSUE PROCESSING ISSUE WAS IDENTIFIED, AFFECTING A SUBSET OF PATHOLOGY CASES LEADING TO TISSUE PROCESSING/FIXATION ISSUES. SEVERAL TISSUE SAMPLES WERE AFFECTED; HOWEVER, THREE CASES REMAINED SUBOPTIMAL FOR READING WHICH AFFECTED PATIENT CARE. THESE CASES EITHER REQUIRE A CHANGE IN TREATMENT PLAN OR A SECOND PROCEDURE TO OBTAIN ADDITIONAL TISSUE SAMPLES.
Patient problems: Insufficient Information
MAUDE report 22110442 ↗
Other PROCESSOR, TISSUE, AUTOMATED devices
- HistoCore PELORIS HistoCore PELORIS 3 (100-120V)Leica Biosystems Melbourne Pty Ltd · Processor, Tissue, Automated1 recall28 reports
- HistoCore PEGASUS 000000014048858005Leica Biosystems Nussloch GmbH · PROCESSOR, TISSUE, AUTOMATED1 recall14 reports
- ASP6025 230V/50-60 Hz 000000014049543267Leica Biosystems Nussloch GmbH · PROCESSOR, TISSUE, AUTOMATED10 reports
- HistoCore PEGASUS Plus 000000014048858007Leica Biosystems Nussloch GmbH · PROCESSOR, TISSUE, AUTOMATED9 reports
- Leica ASP300 S - 230-240V 000000014047643514Leica Biosystems Nussloch GmbH · PROCESSOR, TISSUE, AUTOMATED5 reports
- HistoCore PEARL 000000014049350667Leica Biosystems Nussloch GmbH · PROCESSOR, TISSUE, AUTOMATED4 reports
- Leica TP1020 VF/accessories 1491020US02Leica Biosystems Nussloch GmbH · PROCESSOR, TISSUE, AUTOMATED4 reports
- ASP6025 120V/50-60 Hz 000000014049543268Leica Biosystems Nussloch GmbH · PROCESSOR, TISSUE, AUTOMATED1 report
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page