Skip to content

DISPOSABLE BIOPSY FORCEPS FB-211K (REF N5431430)Recalls & reported problems

Olympus Medical Systems Corp. · Class 1

All models of DISPOSABLE BIOPSY FORCEPS (23)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 04953170389481), received between May 31, 2023 and Jun 15, 2023 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Break” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Break2

Patient problems

  • No Clinical Signs, Symptoms or Conditions2

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJun 15, 2023Break; Break

    THE CUSTOMER REPORTED TO OLYMPUS, THE DISPOSABLE BIOPSY FORCEPS WAS BROKEN AT THE BEGINNING OF THE DIAGNOSTIC BRONCHIAL BIOPSY PROCEDURE, WHEN REMOVING THE BIOPSY FORCEPS OUT OF THE WORKING CHANNEL AND OPENING THE CUPS, PRIOR TO TAKING BIOPSY SAMPLES. THE PROCEDURE WAS COMPLETED WITH NO DELAY USING A SIMILAR DEVICE. THERE WERE NO REPORTS OF PATIENT HARM.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17140462 ↗
  • MalfunctionMay 31, 2023Break; Break

    THE CUSTOMER REPORTED TO OLYMPUS, THE DISPOSABLE BIOPSY FORCEPS WIRE BROKE ASSOCIATED WITH THE OPENING AND CLOSING MECHANISM DURING BIOPSY. THE ISSUE WAS FOUND DURING PROCEDURE, AND THE TYPE OF PROCEDURE WAS DIAGNOSTIC - BIOPSY. THERE WERE NO REPORTS OF PATIENT HARM. RELATED PATIENT IDENTIFIER: (B)(6).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 17032054 ↗

FDA clearance and classification

The FDA regulates product code FCL (forceps, biopsy, non-electric) under 21 CFR 876.1075 as a Class I device. 21 CFR 876.1075 ↗

Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the DISPOSABLE BIOPSY FORCEPS FB-211K

Has the DISPOSABLE BIOPSY FORCEPS FB-211K been recalled?

No FDA recall record in our data names this exact device identifier (DI 04953170389481), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the DISPOSABLE BIOPSY FORCEPS FB-211K?

The FDA's MAUDE database lists 2 adverse event reports for this device, received between May 31, 2023 and Jun 15, 2023. In those reports, the most common specific device problem is “Break” (2). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the DISPOSABLE BIOPSY FORCEPS FB-211K?

None of the reports are classified as deaths, 0 as injuries and 2 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the DISPOSABLE BIOPSY FORCEPS FB-211K FDA approved?

Devices of this type (product code FCL) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Olympus Medical Systems Corp.

Who makes the DISPOSABLE BIOPSY FORCEPS FB-211K, and is it still sold?

The FDA's device database lists Olympus Medical Systems Corp. as the company responsible for it (brand DISPOSABLE BIOPSY FORCEPS, model FB-211K). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Forceps, Biopsy, Non-Electric devices

All Forceps, Biopsy, Non-Electric devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page