Terumo Corporation · PROGREAT Microcatheter Coaxial System · Class 2

All models of PROGREAT (10)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 04987350729286), received between Jul 25, 2022 and Jul 28, 2026 — classified as 2 injuries, 2 malfunctions.

The most frequently reported specific device problem is “Break” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 1 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 2 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break2
  • Detachment of Device or Device Component2
  • Material Fragmentation1
  • Material Separation1
  • Physical Resistance/Sticking1

Patient problems

  • Foreign Body In Patient2
  • No Clinical Signs, Symptoms or Conditions2

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • InjuryJul 28, 2026Break; Detachment of Device or Device Component

    Terumo Medical Corporation received the following information: It was reported that during a Visceral procedure, the progreat broke off inside the patient. On 10 July 2026: Additional information received: There was no blood loss. The event occurred during the Visceral procedure. The progreat fragment remains inside the patient.

    Patient problems: Foreign Body In Patient

    MAUDE report 50059905 ↗
  • InjuryJul 28, 2026Break; Detachment of Device or Device Component

    Terumo received the following information: It was reported that during a Visceral procedure, the progreat broke off inside the patient.Additional information was received On 10 July 2026: There was no blood loss. The event occurred during the Visceral procedure. The progreat fragment remains inside the patient.

    Patient problems: Foreign Body In Patient

    MAUDE report 50059904 ↗
  • MalfunctionJan 14, 2026Material Fragmentation; Physical Resistance/Sticking

    TERUMO MEDICAL CORPORATION RECEIVED THE REPORTED INFORMATION. THE SYSTEM WITH WIRE WAS VERY "STICKY" TO THE POINT THEY COULD BARELY REMOVE THE WIRE FROM THE CATHETER EVEN AFTER FLUSHING THROUGH BOTH PORTS. THE PROCEDURE WAS UNKNOWN, AND THE PATIENT WAS NOT AFFECTED. THE DEVICE WAS FLUSHED FROM BOTH PORTS' MULTIPLE TIMES, EVEN ALONGSIDE THE WIRE; HOWEVER, THEY COULD NOT GET THE WIRE OUT. THE WIRE WAS STUCK WITHIN THE CATHETER, AND THE WIRE ITSELF ENDED UP SHREDDING APART.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24068109 ↗
  • MalfunctionJul 25, 2022Material Separation; Material Separation

    THE USER FACILITY REPORTED THAT THE DURING A LEFT INTERNAL ILIAC ARTERY EMBOLIZATION PROCEDURE. A PROGREAT COAXIAL 2.8FR X 130CM WAS ADVANCED THROUGH 4FR X 100CM ANGLED GLIDECATH. DUE TO TORTUOSITY AND COMPLEX ANATOMY ACCESS TOOK A WHILE. COAXIAL GLIDEWIRE GT WAS SWITCHED OUT FOR AN .018" X 300CM GLIDE WIRE ADVANTAGE FOR SUPPORT. PHYSICIAN NOTED THAT 2.8FR PROGREAT WAS FEELING TIGHT AND GETTING STUCK IN GLIDECATH. 2.8FR PROGREAT WAS SWITCHED OUT FOR A 2.4FR X 130CM PROGREAT. THE CATHETER WAS FLUSHED AND PREPPED AND A GWA WIRE WAS WIPED. HOWEVER, THE PROGREAT GOT STUCK ON THE WIRE. THE PROGREAT REMOVED AND WIRE WIPED AND PROGREAT FLUSHED. HOWEVER, 2.4FR PROGREAT GOT STUCK AGAIN. THIS TIME SIGNIFICANT FORCE WAS REQUIRED TO REMOVE THE PROGREAT AND DURING THAT TIME THE PROGREAT SEPARATED AT DISTAL SECTION OF MICROCATHETER WHERE COLOR CHANGES TO GREY. WIRE ACCESS WAS LOST AND A NEW GWA .018" X 300CM WIRE OPENED AND USED. PROCEDURE CONTINUED BUT HAD TO BE STOPPED AS COMPLEX ANATOMY AND FLUORO TIME AND PATIENT RADIATION EXPOSURE WERE BECOMING A CONCERN. PATIENT WILL NEED TO BE BROUGHT BACK FOR AMPLATZER PLUG IN DISTAL VESSEL. ESTIMATED BLOOD LOSS WAS LESS THAN 250CC'S. THE PATIENT WAS IN

    Patient problems: No Clinical Signs, Symptoms or Conditions