PROGREAT MC*PE28131YBRecalls & reported problems
Terumo Corporation · PROGREAT Microcatheter Coaxial System · Class 2
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 7
- Deaths reported
- 0
- Injuries reported
- 4
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 04987350771810), received between Nov 22, 2016 and Sep 13, 2024 — classified as 4 injuries, 3 malfunctions.
The most frequently reported specific device problem is “Break” (4 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Break4
- Activation, Positioning or Separation Problem1
- Difficult to Remove1
- Material Separation1
- Physical Resistance/Sticking1
- Positioning Problem1
Patient problems
- No Consequences Or Impact To Patient3
- No Clinical Signs, Symptoms or Conditions2
- No Code Available2
Recent adverse event reports
The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 13, 2024Difficult to Remove; Positioning Problem; Difficult to Remove; Positioning Problem
THE PATIENT UNDERWENT A UTERINE ARTERY EMBOLIZATION VIA FEMORAL ACCESS. A CATHETER WAS INSERTED INTO THE PATIENT'S HYPOGASTRIC ARTERY, AND THE 2.8FR X 130CM PROGREAT MICROCATHETER WAS USED TO SELECT THE ARTERY. THE ORIGINAL WIRE FROM THE MICROCATHETER WAS REPLACED WITH A .016 FATHOM WIRE. THIS ASSEMBLY WAS THREADED THROUGH THE TOUHY INCLUDED WITH THE PROGREAT AND INTRODUCED INTO THE PATIENT. THE FELLOW REPORTED NO ISSUES IN ADVANCING THE MICROCATHETER THROUGH THE TOUHY, AND IT DID NOT APPEAR TO KINK OR CATCH DURING INSERTION. HOWEVER, WHEN THE MICROCATHETER WAS ADVANCED OVER THE WIRE INTO THE BODY, THE WIRE WAS OBSERVED PROTRUDING FROM THE SIDE RATHER THAN THE END, SUGGESTING A SIDEHOLE. ATTEMPTS TO RETRACT THE MICROCATHETER WITHIN THE BASE CATHETER LED TO THE SEPARATION OF THE PROGREAT'S TIP, WHICH DID NOT RETRACT WITH THE MICROCATHETER. THE PHYSICIAN THEN REMOVED THE WIRE, MICROCATHETER, AND CATHETER TOGETHER, AND THE PROGREAT'S TIP WAS RETRIEVED WITH THEM. A NEW MICROCATHETER AND WIRE WERE USED TO CONTINUE, AND THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITH THE PATIENT'S CONDITION REMAINING STABLE AND NO REMNANTS OF THE DAMAGED PROGREAT LEFT INSIDE. ADDITIONAL INFORMATION WAS REC
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20215349 ↗MalfunctionMay 17, 2023Activation, Positioning or Separation Problem; Physical Resistance/Sticking; Activation, Positioning or Separation Problem; Physical Resistance/Sticking
THE USER FACILITY REPORTED THAT THE PHYSICIAN WAS FINISHING A THORACIC DUCT EMBOLIZATION DIRECT PERCUTANEOUS APPROACH VIA COOK 22G CHIBA NEEDLE. UPON REMOVING 2.8 THE PROGREAT WITH V18 WIRE IN IT, THE WIRE GOT STUCK INSIDE THE MICROCATHETER AND CHIBA NEEDLE. THE DOCTOR PULLED EXTREMELY HARD, AND IT WAS ALL REMOVED. ALL THE ITEMS CAME OUT. THE PATIENT WAS FINE. THERE WAS NO PATIENT INJURY OR INTERVENTION NEEDED. THE PATIENT WAS RECOVERING FROM THE THORACIC DUCT EMBOLIZATION. THE PROCEDURE WAS SUCCESSFUL.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16946736 ↗InjuryAug 26, 2019Break; Break
THE USER FACILITY REPORTED THAT THE RADIFOCUS CATHETER BROKE APART IN THE EXTERNAL CAROTID ARTERY. THE PATIENT'S CONDITION WAS REPORTED TO BE FINE. THE PROCEDURE WAS SUCCESSFUL. ADDITIONAL INFORMATION WAS RECEIVED ON 05AUG2019. THE PROCEDURE WAS A VISCERAL PROCEDURE. THE BROKEN PIECE WAS RETRIEVED FROM THE PATIENT. THE PATIENT'S CONDITION WAS STABLE.
Patient problems: No Code Available
MAUDE report 8931084 ↗InjuryAug 26, 2019Break; Break
THE USER FACILITY REPORTED THAT THE RADIFOCUS CATHETER BROKE APART IN THE EXTERNAL CAROTID ARTERY. THE PATIENT'S CONDITION WAS REPORTED TO BE FINE. THE PROCEDURE WAS SUCCESSFUL. ADDITIONAL INFORMATION WAS RECEIVED ON 05AUG2019. THE PROCEDURE WAS A VISCERAL PROCEDURE. THE BROKEN PIECE WAS RETRIEVED FROM THE PATIENT. THE PATIENT'S CONDITION WAS STABLE.
Patient problems: No Code Available
MAUDE report 8931083 ↗InjuryJun 6, 2018Material Separation; Material Separation
THE USER FACILITY REPORTED A PIECE OF THE PROGREAT (2.8 130 CM) CATHETER BROKE OFF IN THE PATIENT'S BODY. THE PHYSICIAN WAS ABLE SNARE THE PIECE OUT, AND THERE WERE NO PIECES REMAINING IN THE PATIENT. THE PROCEDURE WAS SUCCESSFUL AND THE PATIENT WAS DOING FINE. ADDITIONAL INFORMATION WAS RECEIVED ON MAY 29, 2018. THERE WAS NO BLOOD LOSS DUE TO THE PROCEDURE.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 7575249 ↗InjuryAug 24, 2017Break; Break
THE USER FACILITY REPORTED THAT THE TIP WITH MARKER CAME OFF DURING THE PROCEDURE. IT WAS REPORTED THAT THE PATIENT CONDITION IS FINE. IT WAS REPORTED THAT THE PROCEDURE OUTCOME WAS SUCCESSFUL.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 6816116 ↗MalfunctionNov 22, 2016Break; Break
THE USER FACILITY REPORTED DEVICE SEPARATION DURING A PROCEDURE. FOLLOW UP COMMUNICATION WITH THE USER FACILITY CONFIRMED THE FOLLOWING INFORMATION: 76MM OF THE PROXIMAL END OF THE CATHETER BECAME SEPARATED; THE ATTENDING TECH REPORTED THAT THE SEPARATION OF THE CATHETER OCCURRED OUTSIDE OF THE PATIENT'S BODY DURING REMOVAL; THE PROCEDURE WAS COMPLETED; AND THE PATIENT'S CONDITION WAS REPORTED AS GOOD WITH NO IMPACT.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 6122508 ↗
Other CATHETER, INTRAVASCULAR, DIAGNOSTIC devices
- TrapEase Permanent Vena Cava Filter with the VisEase Angiographic Vessel Dilator 466P306AUCordis Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC6 deaths186 reports
- Dragonfly™ OPTIS™ C408646Lightlab Imaging, Inc. · CATHETER, INTRAVASCULAR, DIAGNOSTIC4 deaths150 reports
- Dragonfly OpStar™ 1014651Lightlab Imaging, Inc. · CATHETER, INTRAVASCULAR, DIAGNOSTIC1 recall87 reports
- LANGSTON IPN913559Teleflex Incorporated · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls14 reports
- Trevo 90238Stryker Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls5 reports
- Expo™ H749085263011Boston Scientific Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls3 reports
- Expo™ H74908526501Boston Scientific Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls1 report
- Expo™ H74908526031Boston Scientific Corporation · CATHETER, INTRAVASCULAR, DIAGNOSTIC2 recalls0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.