Skip to content

TheraSphere Y90 Glass Microspheres 18.5 GBq (US Commercial) OTT-SPE-FP-700 (990700.SPE)Recalls & reported problems

Biocompatibles Uk Ltd · TheraSphere Yttrium-90 Glass Microspheres 18.5 GBq Dose (US Commercial) · Class 3 · Implant

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 05060116921687), received between Oct 18, 2024 and Oct 18, 2024 — classified as 1 injury.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 1 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • Pain1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryOct 18, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    ROWAN CLINICAL STUDY. IT WAS REPORTED THAT THE SUBJECT EXPERIENCED PAIN REQUIRING DIAGNOSTIC INTERVENTION AND MEDICATION. THE SUBJECT WAS ENROLLED INTO THE ROWAN STUDY ON (B)(6) 2024. PRE-TREATMENT IMAGING DOCUMENTED AVID UPTAKE IN TARGET LESION; DOSE TO PERFUSED LIVER WAS 663.2 GY. DOSE TO TOTAL NORMAL TISSUE WAS 43.2 GY. LUNG SHUNT CALCULATION WAS (B)(4). ON (B)(6) 2024, TREATMENT WITH THERASPHERE WAS PERFORMED. THERASPHERE WAS ADMINISTERED TO THE LIVER THROUGH THE FEMORAL ARTERY. THREE DOSE VIALS WERE ADMINISTERED. TOTAL ADMINISTERED ACTIVITY DOSE WAS 7.23 GBQ. POST TREATMENT DOSIMETRY DOCUMENTED AVID UPTAKE IN TARGET LESION DISTRIBUTION OF Y90 ON TUMORS. DOSE TO PERFUSED LIVER WAS 884 GY AND DOSE TO TOTAL NORMAL TISSUE WAS 57.4 GY. LUNG DOSE CALCULATION WAS 21.7 GY. ON THE SAME DAY, POST THERASPHERE ADMINISTRATION, THE SUBJECT BEGAN TO EXPERIENCE PAIN IN THE RIGHT HIP TO THE LOWER EXTREMITY. AFTER THE PROCEDURE, THE PI ORDERED A CHECK OF BLOOD FLOW AND STARTED THE PATIENT ON ASA 325 MG. THE SUBJECT WAS REFERRED FOR AN ARTERIAL EVALUATION. THE EVENT WAS TREATED THROUGH ADMINISTRATION OF OXYCODONE.

    Patient problems: Pain

    MAUDE report 20484074 ↗

Other Microspheres Radionuclide devices

All Microspheres Radionuclide devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page