Skip to content

Multichem AE AE623XRecalls & reported problems

Techno-Path Manufacturing Limited · Class 1

All models of Multichem AE (3)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Adverse event reports
0
Deaths reported
0
Injuries reported
0
Recalls naming it
1

Summary

No MAUDE adverse event reports in our data reference this device identifier directly.

1 FDA recall record name this device's identifier, 1 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Recalls naming this device

  1. Aug 14, 2026Class IIOpen, Classified

    A routine stability studies have identified a stability drift affecting the Ammonia (NH4+) analyte in specific lots of Multichem AE quality control material. Additional testing confirmed that the labelled shelf-life performance claim for the Ammonia analyte can no longer be supported for the affected lots. This issue is limited to the Ammonia analyte only. The impacted device may cause delay of issuing results to the physician. Delayed recognition and diagnosis of elevated levels may impact in timely treatment of life-threatening levels described within medical toxicity intervention decision points.

    Z-0207-2027 · Root cause: Under Investigation by firm · Recall details · FDA record ↗

FDA clearance and classification

The FDA regulates product code OHQ (multi-analyte controls unassayed) under 21 CFR 862.1660 as a Class I device. 21 CFR 862.1660 ↗

Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

FDA definition of this device type: A quality control material (unassayed) for clinical chemistry is a device intended for medical purposes for use in a test system to estimate test precision and to detect systematic analytical deviations that may arise from reagent or analytical instrument variation. A quality control material (unassayed) may be used for proficiency testing in interlaboratory surveys. This generic type of device includes controls (unassayed) for blood gases, electrolytes, enzymes, multianalytes, single (specified) analytes, or urinalysis controls.

Common questions about the Multichem AE AE623X

Has the Multichem AE AE623X been recalled?

Yes. 1 FDA recall record names this device's identifier, and it is still open. The recall, Z-0207-2027 (Class II), began on Aug 14, 2026: A routine stability studies have identified a stability drift affecting the Ammonia (NH4+) analyte in specific lots of Multichem AE quality control material. Additional testing confirmed that the labelled shelf-life… If you use this device, follow the manufacturer's notice and your healthcare provider's advice.

Is the Multichem AE AE623X FDA approved?

Devices of this type (product code OHQ) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Techno-Path Manufacturing Limited.

Who makes the Multichem AE AE623X, and is it still sold?

The FDA's device database lists Techno-Path Manufacturing Limited as the company responsible for it (brand Multichem AE, model AE623X). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Multi-Analyte Controls Unassayed devices

All Multi-Analyte Controls Unassayed devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page