Millipede 088 Access Catheter 2.0Recalls & reported problems

Perfuze Limited · The Millipede 088 Access Catheter consists of the catheter, a rotating hemostasis valve (RHV) and a valve crossing tool. The catheter, RHV and valve crossing tool are provided sterile. They are sterilized by ethylene oxide (EO). The Millipede 088 Access Catheter is a single lumen, coil-reinforced, variable stiffness catheter. The distal segment has a hydrophilic coating for navigation through the vasculature. The catheter has a radiopaque marker located at its distal end for visualization under fluoroscopy. The valve crossing tool is used to open the valve of the access sheath and to facilitate insertion of the Millipede 088 Access Catheter through the access sheath without damage. The RHV is assembled onto the hub of the Millipede 088 Access Catheter and is used to maintain hemostasis during infusion of saline and contrast agent and insertion of other devices through the Millipede 088 Access Catheter The Millipede 088 Access Catheter is indicated for use in facilitating the insertion and guidance of microcatheters into a selected blood vessel in the neurovasculature. · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 05391539370142), received between Dec 5, 2024 and Dec 5, 2024 — classified as 1 injury.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 1 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • Thromboembolism1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryDec 5, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    A PATIENT WITH A NIHSS SCORE OF 17 AND BASELINE MTICI SCORE OF 0 WAS TREATED FOR A LEFT MIDDLE CEREBRAL ARTERY OCCLUSION. A THIRD PARTY 8F SHEATH WAS USED FOR ACCESS. THE MILLIPEDE 088 CATHETER WAS NAVIGATED OVER A MILLIPEDE 070 CATHETER. THE MILLIPEDE CATHETERS WERE NAVIGATED OVER A THIRD PARTY MICROCATHETER AND GUIDEWIRE. IT WAS RECORDED THAT THE CLOT WAS CROSSED WITH THE THIRD PARTY MICROCATHETER AND GUIDEWIRE DURING EACH PASS. AFTER 3 PASSES, IT WAS NOTED THAT THERE WAS EMBOLIZATION OF CLOT TO THE LEFT ANTERIOR CEREBRAL ARTERY. A THIRD PARTY STENTRIEVER WAS USED IN COMBINATION WITH ASPIRATION FOR TWO SUBSEQUENT PASSES, BUT THE EMBOLUS COULD NOT BE RETRIEVED. THE FINAL MTICI SCORE AT THE END OF THE PROCEDURE WAS 2B. FOLLOWING THE PROCEDURE, THE PATIENT RAPIDLY DETERIORATED AND THE PATIENT'S FAMILY DECLINED FURTHER CONTINUANCE OF CARE. THE PATIENT DIED 5 DAYS AFTER THE PROCEDURE. THE TREATING PHYSICIAN ATTRIBUTED THE DEATH TO THE SEVERITY OF THE STROKE AND THE PATIENT'S AGE. ACCORDING TO THE PHYSICIAN, THE STROKE WAS RAPIDLY EVOLVING TO A LARGER ISCHEMIC STROKE WHICH LED TO EARLY NEUROLOGICAL DETERIORATION DESPITE ARTERIAL RECANALIZATION.

    Patient problems: Thromboembolism

    MAUDE report 20851300 ↗