Sharesource Connectivity Platform 5C9400 (UDI 05413765565694)Recalls & reported problems
Baxter International Inc. · Sharesourece is a web-based connectivity platform that allows authorized users, including nephrologists, clinicians, and nurses in the dialysis center, to remotely view and manage treatment information sent from the Amia APD System. · Class 2
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 05413765565694), received between Mar 30, 2026 and Mar 30, 2026 — classified as 1 injury.
8 other recalls cover devices cleared under the same FDA submission (K151525); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- Insufficient Information1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryMar 30, 2026Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT TWO AUTOMATED PERITONEAL DIALYSIS (PD) PATIENTS USING KAGUYA CYCLERS WITH SHARESOURCE WERE HOSPITALIZED DUE TO "FLOODING", FURTHER DESCRIBED AS "OUTFLOW MODE". THE REPORTER FURTHER INFORMED THAT DIFFICULTY WAS ENCOUNTERED WITH SOME OF THE PARAMETERS PROGRAMMED IN SHARESOURCE, INCLUDING THE "DISCONNECT STATE", WHEREBY PATIENTS SEEM TO END THERAPY "STILL FLOODED". THERE WAS NO REPORT OF PATIENT SYMPTOMS. THERE WAS NO REPORT OF MEDICAL INTERVENTION ASSOCIATED WITH THIS EVENT. AT THE TIME OF THIS REPORT, THE PATIENT OUTCOME AND ACTION TAKEN WITH PD THERAPY WAS NOT REPORTED. ADDITIONAL INFORMATION HAS BEEN REQUESTED TO PROVIDE DETAILS ABOUT THE EVENT.
Patient problems: Insufficient Information
MAUDE report 24716961 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K151525. One submission often covers many models, so check the product and lot details in each record.
- Z-0550-2024 · Nov 15, 2023 · Open, ClassifiedBaxter Amia Automated Peritoneal Dialysis (APD) Cycler Set, REF 5C5479
- Z-2174-2021 · Jun 30, 2021 · TerminatedKaguya Automated Peritoneal Dialysis System
- Z-2173-2021 · Jun 30, 2021 · TerminatedSharesource Connectivity Platform for Use with the Amia Automated PD System
- Z-0850-2019 · Dec 11, 2018 · TerminatedKaguya Automated Peritoneal Dialysis System Product Usage: It is intended for automatic control of dialysate solution exchanges in the treatment of adult renal failure patients un
- Z-0849-2019 · Dec 11, 2018 · TerminatedAMIA Automated Peritoneal Dialysis System Product Usage: It is intended for automatic control of dialysate solution exchanges in the treatment of adult renal failure patients und
- Z-2597-2018 · Jul 12, 2018 · Terminatedpower cord for: (a) AMIA Automated PD Cycler, Product Code: 5C9320; (b) Kaguya PD System, Product Code: T5C8500 (Japanese distribution only)
- Z-3133-2017 · Sep 1, 2017 · TerminatedBaxter Amia Automated Peritoneal Dialysis Set with Cassette, REF 5C5479
- Z-1565-2016 · Feb 16, 2016 · TerminatedAutomated peritoneal dialysis (APD) cycler
Other SYSTEM, PERITONEAL, AUTOMATIC DELIVERY devices
- Liberty® Select Cycler 180343Fresenius Medical Care Holdings, Inc. · System, peritoneal, automatic delivery1 recall545 deaths15,896 reports
- Liberty® 050-87216Fresenius Medical Care Holdings, Inc. · SYSTEM, PERITONEAL, AUTOMATIC DELIVERY16 deaths9,148 reports
- Liberty® 050-87212Fresenius Medical Care Holdings, Inc. · SYSTEM, PERITONEAL, AUTOMATIC DELIVERY12 deaths2,169 reports
- Liberty® 180111Fresenius Usa, Inc. · SYSTEM, PERITONEAL, AUTOMATIC DELIVERY126 deaths1,716 reports
- Amia Automated PD Set with Cassette 5C5479Baxter International Inc. · SYSTEM, PERITONEAL, AUTOMATIC DELIVERY1 recall976 reports
- INTERGRATED APD SET L5C4531Baxter International Inc. · SYSTEM, PERITONEAL, AUTOMATIC DELIVERY811 reports
- Liberty 050-87216AFresenius Medical Care Renal Therapies Group, LLC · System, Peritoneal, Automatic Delivery1 death678 reports
- NA R5C4479Baxter Healthcare SA · System, peritoneal, automatic delivery373 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.