SJM™ Masters Series HP 19AHPJ-505Recalls & reported problems

St. Jude Medical, Inc. · Aortic HP Rotatable Mechanical Heart Valve · Class 3 · Implant

All models of SJM Masters Series HP (9)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
5
Deaths reported
3
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 05414734005883), received between Oct 7, 2019 and Oct 26, 2023 — classified as 3 deaths, 1 injury, 1 malfunction.

The most frequently reported specific device problem is “Incomplete Coaptation” (3 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Incomplete Coaptation3
  • Adverse Event Without Identified Device or Use Problem1
  • Fracture1
  • Material Separation1

Patient problems

  • Insufficient Information2
  • Cardiac Arrest1
  • Heart Failure/Congestive Heart Failure1
  • No Clinical Signs, Symptoms or Conditions1
  • No Known Impact Or Consequence To Patient1

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • DeathOct 26, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT ON (B)(6) 2023, A 21MM EPIC PLUS SUPRA WAS IMPLANTED IN A PATIENT. ON (B)(6) 2023, THE DEVICE WAS EXPLANTED DUE TO A PARAVALVULAR LEAK OF 8 MMHG AND AVERAGE GRADIENT OF 35 MMHG. A 19MM SJM MASTERS SERIES HEMODYNAMIC PLUS VALVE WAS IMPLANTED AS A REPLACEMENT. POST IMPLANT, IT WAS REPORTED THAT THE PATIENT PASSED AWAY. THE CAUSE AND DATE OF THE DEATH IS UNKNOWN.

    Patient problems: Insufficient Information

    MAUDE report 18013991 ↗
  • DeathDec 14, 2022Incomplete Coaptation; Incomplete Coaptation

    IT WAS REPORTED THAT ON (B)(6) 2022, A 19MM SJM MASTERS SERIES HEMODYNAMIC PLUS VALVE WAS SELECTED FOR IMPLANTATION. PRIOR TO THE PROCEDURE THE PATIENT WAS REPORTED TO BE STABLE. WHILE IMPLANTING THE VALVE, IT WAS NOTED THAT THE LEAFLETS DID NOT OPEN AND CLOSE PROPERLY. THE DEVICE WAS REMOVED AND REPLACED WITH A NEW 19MM SJM MASTERS SERIES HEMODYNAMIC PLUS VALVE. IT WAS NOTED THAT THERE WAS A PROLONGED PROCEDURE TIME TO PLACE THE NEW VALVE. IT WAS NOTED THAT THE PATIENT HAD REMAINED HEMODYNAMICALLY STABLE THROUGHOUT THE PROCEDURE. AFTER THE PROCEDURE, THE PATIENT WAS PUT ONTO INTROPICAL SUPPORT. IT WAS REPORTED THAT THE PATIENT PASSED AWAY ON AN UNKNOWN DATE DUE TO CHONDROGENIC SHOCK AND HEART FAILURE. DUE TO CHANGING THE VALVE THE PATIENTS PROCEDURE TIME WAS EXTENDED, POSSIBLY CONTRIBUTING TO PATIENT FATALITY.

    Patient problems: Heart Failure/Congestive Heart Failure

    MAUDE report 15978878 ↗
  • DeathSep 23, 2022Incomplete Coaptation; Incomplete Coaptation

    IT WAS REPORTED THAT ON (B)(6) 2022, A 19MM SJM MASTERS SERIES HEMODYNAMIC PLUS VALVE WAS SELECTED FOR IMPLANT. IT WAS NOTED THAT DURING PROCEDURE THE LEAFLETS OF THE VALVE WERE NOT COAPTING PROPERLY. THE DECISION WAS MADE TO EXPLANT THE 19MM MASTERS VALVE AND REPLACE IT WITH A 17MM REGENT VALVE. DUE TO AN UNKNOWN REASON THE PATIENT WAS PRONOUNCED DECEASED. NO ADDITIONAL INFORMATION WAS PROVIDED.

    Patient problems: Cardiac Arrest; Insufficient Information

    MAUDE report 15474111 ↗
  • MalfunctionMay 7, 2021Fracture; Material Separation; Fracture; Material Separation

    ON (B)(6) 2021, A 19MM SJM MASTERS SERIES HEMODYNAMIC PLUS VALVE WAS SELECTED FOR IMPLANT. DURING PROCEDURE IT WAS REPORTED THAT THE LEAFLET BROKE WHILE TRYING TO ROTATE THE VALVE. ALL THE PIECES WERE RECOVERED AND A NEW 19MM SJM MASTERS SERIES HEMODYNAMIC PLUS VALVE WAS SUCCESSFULLY IMPLANTED. THERE WAS A CLINICALLY SIGNIFICANT DELAY IN PROCEDURE HOWEVER, THE PATIENT WAS REPORTED TO BE IN STABLE CONDITION THROUGHOUT THE PROCEDURE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11789645 ↗
  • InjuryOct 7, 2019Incomplete Coaptation; Incomplete Coaptation

    ON (B)(6) 2019, A 19MM MASTERS VALVE WAS SELECTED FOR IMPLANT. AFTER PARACHUTING THE VALVE IT WAS OBSERVED THAT THE LEAFLET WAS NOT OPENING COMPLETELY. THE PATIENT'S NATIVE ANNULUS WAS HEAVILY CALCIFIED WHICH REQUIRED FURTHER DEBRIDEMENT. THE PATIENT REMAINED HEMODYNAMICALLY STABLE HOWEVER THIS RESULTED IN A CLINICALLY SIGNIFICANT DELAY IN THE PROCEDURE.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 9164902 ↗

Other HEART-VALVE, MECHANICAL devices

All HEART-VALVE, MECHANICAL devices →