Skip to content

Pacel™ 401761Recalls & reported problems

St. Jude Medical Cardiovascular Division · Flow Directed Pacing Catheter · Class 2

All models of Pacel (9)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 05414734021906), received between May 13, 2025 and Feb 11, 2026 — classified as 2 malfunctions.

The most frequently reported specific device problem is “Inflation Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 1 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Inflation Problem1
  • Material Separation1
  • Pacing Problem1

Patient problems

  • Insufficient Information1
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • MalfunctionFeb 11, 2026Pacing Problem

    IT WAS REPORTED THAT THE PACEL FLOW DIRECTED PACING CATHETER WAS NOT PACING WHILE THE BALLOON WAS INFLATED. THE PATIENT WAS EXPERIENCING LOSS OF CAPTURE AND BECAME HEMODYNAMICALLY UNSTABLE. THE PHYSICIAN WAS NOTIFIED AND AN ATTEMPT WAS MADE TO REPOSITION THE TRANSVENOUS PACING LINE WITHOUT SUCCESS. THE PACING CATHETER WAS REPLACED TO RESOLVE THE ISSUE. FURTHER INFORMATION WAS REQUESTED BUT WAS NOT PROVIDED.

    Patient problems: Insufficient Information

    MAUDE report 24314028 ↗
  • MalfunctionMay 13, 2025Inflation Problem; Material Separation; Inflation Problem; Material Separation

    DURING THE PROCEDURE, THE BALLOON WAS PROPERLY DEFLATED, BUT DURING REMOVAL, IT WAS FOUND THAT THE BALLOON WAS CRACKED. THE PROCEDURE WAS SUCCESSFULLY COMPLETED WITH NO ADVERSE PATIENT CONSEQUENCES.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22014605 ↗

Other ELECTRODE, PACEMAKER, TEMPORARY devices

All ELECTRODE, PACEMAKER, TEMPORARY devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page