Wi-Box™ AO TransmitterRecalls & reported problems

St. Jude Medical, Inc. · Signal Transceiver · Class 2

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
6
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 05414734054140), received between Mar 4, 2021 and Apr 8, 2026 — classified as 6 malfunctions.

The most frequently reported specific device problem is “Communication or Transmission Problem” (5 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 1 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 2 reportsApr 2026: 1 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Communication or Transmission Problem5
  • Power Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions6

Recent adverse event reports

The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.

  • MalfunctionApr 8, 2026Communication or Transmission Problem

    DURING A PROCEDURE, AN AO READING WAS UNABLE TO BE OBTAINED. MULTIPLE CABLES WERE EXCHANGED WITH NO RESOLUTION. THE PROCEDURE WAS ABANDONED BUT THERE WERE NO ADVERSE CONSEQUENCES TO THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24821068 ↗
  • MalfunctionMar 30, 2026Communication or Transmission Problem

    DURING A DIAGNOSTIC PROCEDURE, THERE WAS AO DRIFT. THE ISSUE WAS FOUND TO BE CAUSED BY THE WI-BOX AND ADAPTER AND MONITOR CABLES. THE PROCEDURE WAS ABANDONED, BUT THERE WERE NO ADVERSE CONSEQUENCES TO THE PATIENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24709100 ↗
  • MalfunctionMar 17, 2026Communication or Transmission Problem

    DURING THE PROCEDURE, COMMUNICATION ISSUES RESULTED IN THE PROCEDURE BEING CANCELLED. IT WAS NOT POSSIBLE TO GET AN AO PRESSURE. THE CORRECT ROOM WAS SELECTED, AND THE CORRECT WI BOX SN WAS POPULATED. THE PROCEDURE WAS CANCELLED AS A RESULT. THE PATIENT'S TREATMENT WAS MOVED TO MEDICAL THERAPY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24619875 ↗
  • MalfunctionMar 10, 2025Communication or Transmission Problem; Communication or Transmission Problem

    DURING A CFR/IMR PROCEDURE, COMMUNICATION ISSUES RESULTED IN THE PROCEDURE BEING CANCELLED. THE NON-ABBOTT (COROVENTIS) SYSTEM DID NOT DETECT AN AO SIGNAL FROM THE TRANSDUCER. THE PRESSURE WIRE WAS EXCHANGED BUT THE ISSUE WAS NOT RESOLVED. THE NON-ABBOTT (COROVENTIS) SYSTEM WAS WORKING AS EXPECTED AND THE ISSUE WAS DEEMED TO BE DUE TO THE WI-BOX. THE PROCEDURE WAS CANCELLED DUE TO NO AO SIGNAL. THERE WERE NO ADVERSE PATIENT CONSEQUENCES.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21561240 ↗
  • MalfunctionMar 28, 2023Power Problem; Power Problem

    DURING A RIGHT HEART CATHETERIZATION PROCEDURE, PRESSURE WAS LOST RESULTING IN CANCELLATION OF THE PROCEDURE. MULTIPLE ATTEMPTS WERE MADE TO RESOLVE THE ISSUE UNSUCCESSFULLY. THE ENTIRE SYSTEM WAS REBOOTED WHICH CONFIRMED THE WI-BOX CRASHED RESULTING IN THE PRESSURES NOT BEING SEEN ON THE MACLAB. THE PROCEDURE WAS THEN CANCELLED WITH NO PATIENT CONSEQUENCES.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16631329 ↗
  • MalfunctionMar 4, 2021Communication or Transmission Problem; Communication or Transmission Problem

    DURING AN RFR PHYSIOLOGY STUDY, WHEN TRYING TO ACQUIRE AO PRESSURE, THE WI-BOX AO TRANSMITTER WAS UNABLE TO ESTABLISH CONNECTION WITH THE PRESSUREWIRE X. THE RED LIGHT CAME ON (NOT READY INDICATOR) ON THE WI-BOX AND POWERED OFF. ALL THE CONNECTIONS TO THE WI-BOX WERE CHECKED, BUT THE ISSUE PERSISTED. THE PROCEDURE WAS ABORTED DUE TO THIS ISSUE. THE WI-BOX WAS REPLACED AND THE ISSUE WAS RESOLVED. THERE WERE NO ADVERSE PATIENT CONSEQUENCES DUE TO THIS ISSUE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 11410952 ↗

Other TRANSMITTERS AND RECEIVERS, PHYSIOLOGICAL SIGNAL, RADIOFREQUENCY devices

All TRANSMITTERS AND RECEIVERS, PHYSIOLOGICAL SIGNAL, RADIOFREQUENCY devices →