Minimed™ Quick-set™ MMT-396A (UDI 05705244018068)Recalls & reported problems

Unomedical A/S · Single use infusion set for subcutaneous infusion. The infusion set must be used as described in the Instruction for Use. · Class 2

All models of MiniMed Infusion Sets (58) · Minimed Quick-set (18)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
18
Deaths reported
0
Injuries reported
14
Recalls naming it
0

Summary

The FDA's MAUDE database contains 18 adverse event reports that list this exact device (DI 05705244018068), received between Sep 1, 2026 and Sep 30, 2026 — classified as 14 injuries, 4 malfunctions.

The most frequently reported specific device problem is “Material Twisted/Bent” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 18 reportsOct 2026: 0 reports20242025202618
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem10
  • Material Twisted/Bent4
  • Complete Blockage2
  • Appropriate Device Problem Term/Code Not Available1
  • Leak/Splash1
  • Loose or Intermittent Connection1
  • Use of Incorrect Control/Treatment Settings1

Patient problems

  • Hyperglycemia14
  • No Clinical Signs, Symptoms or Conditions4
  • Pain1
  • Skin Infection1

Recent adverse event reports

The 18 most recent of 18 reports, in the reporter's own words as published by the FDA.

  • InjurySep 30, 2026Material Twisted/Bent

    It was reported that the patient experienced a bent infusion set cannula and high blood glucose of 300 mg/dL. The high blood glucose persisted for 3 to 4 hours and was treated using the insulin pump on (b)(6)2026.

    Patient problems: Hyperglycemia

    MAUDE report 50946265 ↗
  • InjurySep 30, 2026Material Twisted/Bent

    It was reported that the patient experienced a bent infusion set cannula and high blood glucose of 380 mg/dL for greater than 4 hours. The event was treated with manual insulin injections on (b)(6) 2026.

    Patient problems: Hyperglycemia

    MAUDE report 50946089 ↗
  • InjurySep 30, 2026Complete Blockage; Material Twisted/Bent

    It was reported that the patient experienced a bent infusion set cannula and high blood glucose of 380 mg/dL. The high blood glucose persisted for greater than 4 hours and was treated with manual insulin injections on (b)(6) 2026.

    Patient problems: Hyperglycemia

    MAUDE report 50946082 ↗
  • InjurySep 29, 2026Adverse Event Without Identified Device or Use Problem

    Patient problems: Hyperglycemia

    MAUDE report 50932018 ↗
  • InjurySep 29, 2026Adverse Event Without Identified Device or Use Problem

    Patient problems: Hyperglycemia

    MAUDE report 50932013 ↗
  • InjurySep 29, 2026Adverse Event Without Identified Device or Use Problem

    Patient problems: Hyperglycemia

    MAUDE report 50928590 ↗
  • InjurySep 29, 2026Adverse Event Without Identified Device or Use Problem

    It was reported that the patient experienced skin infection and pain at the site of insertion due to hyperglycemia (260 mg/dl) event on (b)(6) 2026 and was treated with Correction bolus via pump.

    Patient problems: Hyperglycemia; Pain; Skin Infection

    MAUDE report 50928573 ↗
  • InjurySep 28, 2026Adverse Event Without Identified Device or Use Problem

    It was reported that the patient experienced a hyperglycemia event which was treated with a Manual bolus on (b)(6)2026.

    Patient problems: Hyperglycemia

    MAUDE report 50915587 ↗
  • MalfunctionSep 27, 2026Use of Incorrect Control/Treatment Settings

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50910021 ↗
  • InjurySep 25, 2026Adverse Event Without Identified Device or Use Problem

    It was reported that the patient faced hyperglycemia event which was treated with Pen on (b)(6)2026.

    Patient problems: Hyperglycemia

    MAUDE report 50893293 ↗
  • InjurySep 25, 2026Adverse Event Without Identified Device or Use Problem

    It was reported that the patient faced hyperglycemia event which was treated with Pump on (b)(6)2026.

    Patient problems: Hyperglycemia

    MAUDE report 50893269 ↗
  • InjurySep 25, 2026Adverse Event Without Identified Device or Use Problem

    It was reported that the patient faced hyperglycemia event which was treated with Pump on (b)(6) 2026.

    Patient problems: Hyperglycemia

    MAUDE report 50893261 ↗
  • InjurySep 25, 2026Adverse Event Without Identified Device or Use Problem

    It was reported that the patient faced hyperglycemia event which was treated with Pump on 25 Aug 2026.

    Patient problems: Hyperglycemia

    MAUDE report 50893229 ↗
  • InjurySep 25, 2026Adverse Event Without Identified Device or Use Problem

    It was reported that the patient faced hyperglycemia event which was treated with Pump on(b)(6)2026.

    Patient problems: Hyperglycemia

    MAUDE report 50893193 ↗
  • MalfunctionSep 24, 2026Leak/Splash

    It was reported that the patient experienced an infusion set leaking at the site event during use on (b)(6) 2026.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50878608 ↗
  • MalfunctionSep 23, 2026Loose or Intermittent Connection

    It was reported that patient experienced infusion set leak at the quick release due to quick release was not tightly connected event on (b)(6)2026.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50866887 ↗
  • MalfunctionSep 7, 2026Appropriate Device Problem Term/Code Not Available

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 50652826 ↗
  • InjurySep 1, 2026Complete Blockage; Material Twisted/Bent

    The patient reported experiencing infusion set bent cannula after insertion event on (b)(6)V2026 which disrupted insulin delivery and resulted in hyperglycemia, the elevated blood glucose was successfully managed by the patient through self-administration of insulin via multiple daily injections, resolving the issue with no further complications.

    Patient problems: Hyperglycemia

    MAUDE report 50547795 ↗

Other Set, Administration, Intravascular devices

All Set, Administration, Intravascular devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page