Adverse event reports
9
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 9 adverse event reports that list this exact device (DI 05705244019959), received between May 20, 2024 and Mar 26, 2026 — classified as 2 injuries, 7 malfunctions.

The most frequently reported specific device problem is “Leak/Splash” (8 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 1 reportsJun 2024: 2 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 1 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 5 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520265
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Leak/Splash8
  • No Apparent Adverse Event2

Patient problems

  • No Clinical Signs, Symptoms or Conditions7
  • Elevated Ketones/ Diabetic Ketoacidosis2

Recent adverse event reports

The 9 most recent of 9 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 26, 2026Leak/Splash

    REFRENCE NUMBER (B)(4) EVENT OCCURRED IN AUSTRALIA. IT WAS REPORTED THAT THE PATIENT EXPERIENCED LEAKAGE AT THE INFUSION SITE ON (B)(6) 2023. NO FURTHER INFORMATION AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24701611 ↗
  • MalfunctionMar 26, 2026Leak/Splash

    REFRENCE NUMBER (B)(4). EVENT OCCURRED IN AUSTRALIA. IT WAS REPORTED THAT THE PATIENT EXPERIENCED LEAKAGE AT THE INFUSION SITE ON (B)(6) 2023. NO FURTHER INFORMATION AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24701548 ↗
  • MalfunctionMar 26, 2026Leak/Splash

    REFRENCE NUMBER (B)(4) EVENT OCCURRED IN AUSTRALIA IT WAS REPORTED THAT THE PATIENT EXPERIENCED LEAKAGE AT THE INFUSION SITE ON (B)(6) 2023. NO FURTHER INFORMATION AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24701541 ↗
  • MalfunctionMar 26, 2026Leak/Splash

    REFRENCE NUMBER (B)(4). EVENT OCCURRED IN AUSTRALIA. IT WAS REPORTED THAT THE PATIENT EXPERIENCED LEAKAGE AT THE INFUSION SITE ON (B)(6) 2023. NO FURTHER INFORMATION AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24701538 ↗
  • MalfunctionMar 26, 2026Leak/Splash

    REFERENCE NUMBER (B)(4). EVENT OCCURRED IN AUSTRALIA. IT WAS REPORTED THAT THE PATIENT EXPERIENCED LEAKAGE AT THE INFUSION SITE ON (B)(6) 2023. NO FURTHER INFORMATION AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24701535 ↗
  • InjurySep 16, 2024No Apparent Adverse Event; No Apparent Adverse Event

    REFERENCE NUMBER (B)(4). EVENT OCCURRED IN THE UNITED STATES ON 31-JUL-2024, IT WAS REPORTED THAT THE PATIENT WAS HOSPITALIZED DUE DIABETIC KETOACIDOSIS. NO FURTHER INFORMATION AVAILABLE.

    Patient problems: Elevated Ketones/ Diabetic Ketoacidosis

    MAUDE report 20222184 ↗
  • MalfunctionJun 26, 2024Leak/Splash; Leak/Splash

    UNOMEDICAL REFERENCE NUMBER (B)(4). EVENT OCCURRED IN AUSTRALIA. IT WAS REPORTED THAT PATIENT FACED INFUSIONS SET LEAKAGE EVENT ON (B)(6) 2024 AFTER 24 HOURS. LEAK BEFORE END OF 3 DAYS. NO FURTHER INFORMATION AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19621052 ↗
  • InjuryJun 9, 2024Leak/Splash; No Apparent Adverse Event; Leak/Splash; No Apparent Adverse Event

    UNOMEDICAL REFERENCE NUMBER (B)(4). EVENT OCCURRED IN THE UNITED STATES IT WAS REPORTED BY THE PATIENT HAD HIGH BLOOD GLUCOSE 497 MG/DL WHEN ADMITTED TO HOSPITAL ON (B)(6) 2024 FROM 9:30 AM TO 3PM. WHEN THE PATIENT WAS ADMITTED TO THE HOSPITAL, SYMPTOMS WERE FEELING SICK/UNWELL AND REASON OF HOSPITALIZATION WAS DIABETIC KETOACIDOSIS. THE PATIENT TREATED WITH IV INSULIN DRIP (INTRAVENOUS INSULIN INFUSION) AND REQUESTED A NORMAL PUMP. NO FURTHER INFORMATION WAS AVAILABLE.

    Patient problems: Elevated Ketones/ Diabetic Ketoacidosis

    MAUDE report 19495201 ↗
  • MalfunctionMay 20, 2024Leak/Splash; Leak/Splash

    UNOMEDICAL REFERENCE NUMBER (B)(4). EVENT OCCURRED IN AUSTRALIA. IT WAS REPORTED THAT PATIENT FACED INFUSION SET LEAK EVENT ON 19-APR-2024. THE LEAK WAS AT SIDE OF THE ATTACHMENT TO THE BODY. UNOMEDICAL DO NOT SEE BENT/KINKING AS BEING RELATED TO HUMAN FACTORS, BUT RATHER AS A TRAINING ISSUE INCLUDING CORRECT CHOICES OF INSERTION SITES AND INFUSION SETS AND CANNULA LENGTH. FURTHERMORE, THE SOFT CANNULA IS A FLEXIBLE MATERIAL THAT DURING USE AND UPON REMOVAL CAN BEND SLIGHTLY. NO FURTHER INFORMATION AVAILABLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19349354 ↗

Other Set, Administration, Intravascular devices

All Set, Administration, Intravascular devices →

Sources and updates